Laserfiche WebLink
Power Optimizer <br />For Residential Installations <br />S440, S500 <br />Rated Input DC Power(11 <br />440 500 <br />W <br />Absolute Maximum Input Voltage (Voc) <br />60 <br />Vdc <br />MPPT Operating Range <br />8-60 <br />Vdc <br />Maximum Short Circuit Current (Isc) of Connected PV Module <br />14.5 115 <br />Adc <br />Maximum Efficiency <br />99.5 <br />% <br />Weighted Efficiency <br />98.6 <br />% <br />Overvoltage Category <br />II <br />OUTPUT DURING OPERATION <br />Maximum Output Current 15 Adc <br />Maximum Output Voltage 60 Vdc <br />OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) <br />Safety Output Voltage per Power Optimizer 1 Vdc <br />STANDARD COMPLIANCE <br />EMC <br />FCC Part 15 Class 3, IEC61000-6-2, IEC61000-6-3, CISPRI1, EN-55011 <br />Safety <br />IEC62109-1 (class II safety), UL1741 <br />Material <br />UL94 V-0, UV Resistant <br />ROHS <br />Yes <br />Fire Safety <br />VDE-AR-E 2100-712:2013-05 <br />INSTALLATION SPECIFICATIONS <br />Maximum Allowed System Voltage <br />1000 <br />Vdc <br />Dimensions (W x L x H) <br />129 x 155 x 30 <br />mm <br />Weight (including cables) <br />655 / 1.5 <br />gr / lb <br />Input Connector <br />MC4(1) <br />Input Wire Length <br />0.1 <br />m <br />Output Connector <br />MC4 <br />Output Wire Length <br />(+) 2.3, (-) 0.10 <br />m <br />Operating Temperature Range(') <br />-40 to +85 <br />C <br />Protection Rating <br />IP68 / NEMA6P <br />Relative Humidity <br />0 - 100 <br />% <br />(1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed <br />2) For other connector types please contact SolarEdge <br />3) For ambient temperature above +70°C / +158°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details <br />Minimum String Length ID--, 5440, 5500 8 16 8 <br />nr+l...f�orol <br />Maximum String Length (Power Optimizers) 25 50 <br />Maximum Nominal Power per String(a) 5700 11250(s' 12750(b) W <br />Parallel Strings of Different Lengths or Orientations Yes <br />(4) If the inverters rated AC power s maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC <br />power Refer to: https://www.solaredge.com/sites/default/files/se-power-optimizer-single-string-design-application-note.pdf <br />(5) For the 230/400V grid: it is allowed to install up to 13,500W per string when the maximum power difference between each string is 2,000W <br />(6) For the 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W <br />(7) It is not allowed to mix S-series and P-series Power Optimizers in new installations <br />© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. E Ron <br />All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2021 DS-000091-1.2-ENG. Subject to change without notice. V <br />