My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
118 69TH ST SE 2023-04-03
>
Address Records
>
69TH ST SE
>
118
>
118 69TH ST SE 2023-04-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 1:28:38 PM
Creation date
4/3/2023 8:01:59 AM
Metadata
Fields
Template:
Address Document
Street Name
69TH ST SE
Street Number
118
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Single Phase Inverter <br />Wit HD -Wave Technology for North America <br />SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ <br />SE760OH-US / SE10000H-US / SE1140OH-US <br />OUTPUT <br />Rated AC Power Output <br />3000 <br />3800 @ 240V <br />5000 <br />6000 @ 240V <br />7600 <br />10000 <br />11400 @ 240V <br />VA <br />3300 @ 208V <br />5000 @ 208V <br />10000 @ 208V <br />Maximum AC Power Output <br />3000 <br />3800 @ 240V <br />5000 <br />6000 @ 240V <br />7600 <br />10000 <br />11400 @ 240V <br />VA <br />3300 @ 208V <br />5000 @ 208V <br />10000 @ 208V <br />AC Output Voltage Min.-Nom.-Max. <br />✓ <br />✓ <br />✓ <br />✓ <br />✓ <br />✓ <br />✓ <br />Vac <br />(211 - 240 - 264) <br />AC Output Voltage Min.-Nom.-Max. <br />✓ <br />✓ <br />✓ <br />Vac <br />(183 - 208 - 229) <br />AC Frequency (Nominal) <br />59.3 - 60 - 60.50) <br />Hz <br />Maximum Continuous Output <br />12.5 <br />16 <br />21 <br />25 <br />32 <br />42 <br />47.5 <br />A <br />Current @240V <br />Maximum Continuous Output <br />- <br />16 <br />- <br />24 <br />- <br />- <br />48.5 <br />A <br />Current @208V <br />GFDI Threshold <br />1 <br />A <br />Utility Monitoring, Islanding <br />Protection, Country Configurable <br />Yes <br />Thresholds <br />INPUT <br />Maximum DC Power @240V <br />4650 <br />5900 <br />7750 <br />9300 <br />11800 <br />15500 <br />17650 <br />W <br />Maximum DC Power @208V <br />- <br />5100 <br />7750 <br />15500 <br />W <br />Transformer -less, Ungrounded <br />Yes <br />Maximum Input Voltage <br />480 <br />Vdc <br />Nominal DC Input Voltage <br />380 400 <br />Vdc <br />Maximum Input Current @240V(1) <br />8.5 <br />105 <br />13.5 <br />16.5 <br />20 <br />27 <br />30.5 <br />Adc <br />Maximum Input Current @208V(z) <br />- <br />9 <br />13.5 <br />- <br />- <br />27 <br />Adc <br />Max. Input Short Circuit Current <br />45 <br />Adc <br />Reverse -Polarity Protection <br />Yes <br />Ground -Fault Isolation Detection <br />600kn Sensitivity <br />Maximum Inverter Efficiency <br />99 99.2 <br />% <br />CEC Weighted Efficiency <br />gg <br />99 @ 240V <br />98.5 @ 208V <br />o <br />Nighttime Power Consumption <br />< 2.5 <br />W <br />ADDITIONAL FEATURES <br />Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) <br />Revenue Grade Data, ANSI C12.20 Optional(') <br />Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect <br />2017 690.12 <br />STANDARD COMPLIANCE <br />Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 <br />Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) <br />Emissions FCC Part 15 Class B <br />INSTALLATION SPECIFICATIONS <br />AC Output Conduit Size / AWG <br />3/4' minimum / 14-6 AWG <br />3/4" minimum /14-4 AWG <br />Range <br />DC Input Conduit Size / # of Strings / <br />AWG Range <br />3/4" minimum / 1-2 strings / 14-6 AWG <br />3/4" minimum / 1-3 strings / 14-6 AWG <br />Dimensions with Safety Switch <br />17.7 x 14.6 x 6.8 / 450 x 370 x 174 <br />21.3 x 14.6 x 7.3 / 540 x 370 x 185 <br />in / <br />(HxWxD) <br />mm <br />Weight with Safety Switch <br />22110 25.1 / 11.4 26.2 / 11.9 <br />38.8 / 17.6 <br />lb / kg <br />Noise <br />< 25 <50 <br />dBA <br />Cooling <br />Natural Convection <br />Operating Temperature Range <br />-40 to +140 / -25 to +60(4) (-40'F / -40'C option)(') <br />`F / -C <br />Protection Rating <br />NEMA 4X (Inverter with Safety Switch) <br />O) For other regional settings please contact SolarEdge support <br />(2) A higher current source may be used; the inverter will limit its input current to the values stated <br />(1) Revenue grade inverter P/N: SExxxxH-USOOONNC2 <br />(4) For power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf <br />(s) -40 version P/N: SExxxxH-USOOONNU4 <br />O SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All <br />other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2018N01/ENG NAM. Subject to change without notice. <br />RoHS <br />
The URL can be used to link to this page
Your browser does not support the video tag.