Laserfiche WebLink
5 <br />I <br />I I <br />_4--�BD <br />I I <br />120214"1SL <br />EXIST _ <br />367 CFM D <br />D128 (TYP ALL) 4O <br />I I f <br />2,X16 <br />BD <br />24X24 RR <br />W/CFD <br />24X24 RR �I <br />A D2-1 EXIS <br />2024 RR T 1 270 CI <br />24%24 RR <br />WICFD <br />BD f f T <br />Imo- 28X10 <br />D130 <br />Lt <br />� 1 <br />I I <br />�H� <br />FLOOR. FD AT FLOOR. <br />MECHANICAL PLAN - BUILDINGS B & D - LEVEL 2 <br />GENERALNOTES <br />A. DARK LINE WEIGHT ON DEMO PLANS INDICATES EXISTING WORK THAT IS TO BE <br />DEMOLISHED. DARK LINE WEIGHTS ON NEW PLANS INDICATES NEW WORK. HALF <br />TONED LINE WEIGHT INDICATES EXISTING CONDITIONS WHICH ARE TO REMAIN. <br />B. REFER TO HEATING WATER DIAGRAM. <br />C. PROVIDE ACOUSTICAL TILE CEILINGS AS NECESSARY. FIELD VERIFY REQUIREMENTS. <br />D. FIELD VERIFY ALL LOCATIONS OF SPACE THERMOSTATS. <br />KEYNOTES <br />1 INSTALL NEW VERTICAL AHU AND ASSOCIATED APPURTANCES (WI CUSTOM MIXING <br />BOX). SEE DETAILS 21M-500 AND 4/MS00 FOR MORE INFORMATION. <br />2 INSTALL NEW VERTICAL AHU AND ASSOCIATED APPURTANCES (W/ CUSTOM MIXING <br />BOX). SEE DETAIL 8IM500 FOR MORE INFORMATION. <br />3 INSTALL NEW TEMPERATURE SENSOR WITH INTEGRATED OVERRIDE SWITCH AND CO2 <br />SENSOR. <br />4 INSTALL NEW CEILING DIFFUSER IN GRID CEILING. SEE SCHEDULE ON PAGE M-060. <br />5 INSTALL NEW IN -LINE EXHAUST FAN. RECONFIGURE DUCTWORK AS NEEDED TO <br />CONNECT TO NEW EXHAUST FAN. REINSTALL ACCESS PANEL AND PATCH CEILING AS <br />NEEDED. SEE DETAIL 5IM-500 FOR MORE INFORMATION. <br />I I I <br />—I — — — —I — — - <br />----------------------------------------f— <br />BD 24X24 RR AHU AHU 24X24 RR <br />28X10 1 D2-7 D2-8 1 BD <br />BD AHU <br />20'xt4'1SL 20"x14"1SL D2-9 1 <br />28X10 <br />24X24 RR 24X24 R11 <br />W/CFD WICFD 20"x14"1SL <br />f � <br />i I <br />D107 "501 <br />f f BD <br />0 24X24 RR <br />AHU D2.6 AHU D2-7 AHU D2.8 <br />-� AHU D2-9 <br />Jll T T T 3 T /�24X24 RR <br />WICFD <br />-I - - - EXIST - - - - - <br />1741 Dill AHU D2.13 T -} EXIST 14�CFM 0110 <br />135 CFM~ EXIST AHU D2-10 BD <br />_®y EXIST_ f F ®y 270 CFM T 3 24X24 RR <br />EXIST + 145 CF + <br />R <br />270 CFM EXIST + AHU 1 EXIST / 24X24 R <br />'�i D112 2 -' / T WICFD <br />135 CFM ___ _��_________ _ D2-13_ _ �� ____®135 CFM 0 <br />I I I <br />r - <br />pigp - -- S 50 CFM <br />r 24X12 p113 FLOOR <br />J1 EXIST D140 <br />-- -- 30 CFM <br />f®� EXIST: 16X12DN-Z- D101 <br />y ii + 290 CFM�i X12 EXIST i o 1 <br />J D114 L16X10 340 CFM T <br />L14X8-�-- - L D115 <br />L14X8 <br />1 D2- 0 20"x14" iSL <br />> 14X14 ER WICFD 14X14 ER W/CFD <br />390 CFM 440 CFM <br />r------------J <br />UST <br />ER <br />BY o <br />R. AHU B2-1 <br />T 3 BID DdWN <br />- r 24X24 RR L24X24 RR - - - - - - <br />- f �W/CFD 8 - - - - - - - - <br />ai0 try <br />fe Of Your Building <br />McKINSTRY Co, LLC <br />SEATTLE: <br />5005 3RD AVENUE S <br />PO BOX 24567 <br />SEATTLE, WA 98124 <br />1-800-669-6223 <br />www.mckinstrv.com <br />PROJECT <br />MUKILTEO SD <br />PHASE 10 HVAC <br />IMPROVEMENTS <br />- HORIZON ES <br />222 W CASINO RD <br />EVERETT, WA 98204 <br />CONSULTANTS: <br />D <br />A B I C <br />ISSUE: <br />PERMIT SET <br />05/06/2022 <br />REGISTRATION: <br />�R p,�F WA 'stb <br />s��Q� f�ca�eA <br />52l)1 Q <br />P0.�3,�E'GISTEIL�1�� <br />S10NAL <br />ISSUES: <br />SR ENGINEER: L. HESS <br />DRAWN BY: M. SAFONOV N. HOBURG A. PASSAS <br />QC BY: L. HESS <br />JOB N0: 205557-004 <br />ISSUED ON: 05106/2022 <br />SHEET TITLE: <br />MECHANICAL PLAN - <br />BUILDINGS B & D - <br />LEVEL 2 <br />SCALE: 118" = 1'-0" <br />0 4' 8' 16' <br />SHEET NUMBER: <br />M-104 <br />