Laserfiche WebLink
IQ8 and IQ8+ Microinverters <br />Commonly used module pairings' <br />Module compatibility <br />MPPT voltage range <br />Operating range <br />Min/max start voltage <br />Max input DC voltage <br />Max DC current' [module Isc] <br />Overvoltage class DC port <br />DC port backfeed current <br />PV array configuration <br />Peak output power <br />Max continuous output power <br />Nominal (L-L) voltage/range' <br />Max continuous output current <br />Nominal frequency <br />Extended frequency range <br />Max units per 20 A (L-L) branch circuit4 <br />Total harmonic distortion <br />Overvoltage class AC port <br />AC port backfeed current <br />Power factor setting <br />Grid -tied power factor (adjustable) <br />Peak efficiency <br />CEC weighted efficiency <br />Night-time power consumption <br />Ambient temperature range <br />Relative humidity range <br />DC Connector type <br />Dimensions (HxWxD) <br />Weight <br />Cooling <br />Approved for wet locations <br />Acoustic noise at 1 m <br />Pollution degree <br />Enclosure <br />Environ. category / UV exposure rating <br />W 235 - 350 <br />235 - 440 <br />60-cell/120 half -cell <br />60-cell/120 half -cell and 72-cell/144 half -cell <br />V 27-37 <br />29-45 <br />V 25-48 <br />25-58 <br />V 30 / 48 <br />30 / 58 <br />V 50 <br />60 <br />A <br />15 <br />mA <br />11 <br />0 <br />1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit <br />Q: 6 Q: <br />VA 245 <br />300 <br />VA 240 <br />290 <br />V <br />240 / 211- 264 <br />A 1.0 <br />1.21 <br />Hz <br />60 <br />Hz <br />50 - 68 <br />16 <br />13 <br /><5 <br />mA 30 <br />1.0 <br />0.85leading - 0.85lagging <br />97.5 97.6 <br />97 97 <br />mW 60 <br />-400C to +600C (-40°F to +1400F) <br />4% to 100% (condensing) <br />MC4 <br />212 mm MY) x 175 mm (6.9") x 30.2 mm (1.2") <br />1.08 kg (2.38 Ibs) <br />Natural convection - no fans <br />Yes <br /><60 dBA <br />PD3 <br />Class II double -insulated, corrosion resistant polymeric enclosure <br />NEMA Type 6 / outdoor <br />CA Rule 21(UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 <br />Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section <br />690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to <br />manufacturer's instructions. <br />(1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/ <br />module -compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage <br />range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to <br />local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 <br />