Laserfiche WebLink
Exception: with the Fire Marshal's approval, tents with a maximum square footage of 4,000 <br />square feet shall have the minimum ballasting requirements as follows: <br />• Minimum ballast weight used shall be 1,200 pounds per leg. <br />• Corner shall have two 1,200 pounds ballast weights in place adjacent to each other. <br />• Anchor points shall be % the distance of the leg height from the tent. <br />• Tent feet shall be installed on each leg. <br />Straps/Ropes <br />Straps shall meet the following requirements: <br />• Ropes are not acceptable only ratchet nylon webbing straps with tensile strength rating shall be <br />used to secure all tents. <br />• All methods of securing straps to anchors shall meet the same or greater working loads as <br />specified by the manufacture. If manufacturer does not provide working loads, 1,200 pounds or <br />greater shall be used. <br />• Webbing straps shall be free of tears or excessive frays. <br />Permit Fees <br />Operational Fire Permits for carnivals, fairs, and festivals - https://www.everettwa.gov/306/Fire-Permits <br />Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT P-11 11.25.2019 1 Page 3 <br />