My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2023-04-05
>
Address Records
>
RUCKER AVE
>
3020
>
SNO CO HEALTH DISTRICT
>
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2023-04-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2023 8:38:33 AM
Creation date
4/3/2023 9:52:10 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3020
Tenant Name
SNO CO HEALTH DISTRICT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Specifications <br />General <br />The units shall be horizontal airflow as shipped and <br />convertible to downflow. All units shall be factory <br />assembled, piped, internally wired and fully charged <br />with refrigerant. Units shall be certified to UL Standard <br />1995. All units shall be factory run tested to check <br />cooling operation, fan and blower rotation and control <br />or TXV sequence. Units shall be designed to operate at <br />ambient temperatures between 115°F and 55OF in <br />cooling as manufactured. Cooling performance shall be <br />rated in accordance with AHRI standards. <br />Unit Casing <br />All components shall be mounted in a weather - <br />resistant steel cabinet with an enamel finish. Access <br />panels shall be provided for unit controls and indoor <br />coil and fans. Indoor air section compartment shall be <br />completely insulated with fireproof, permanent, <br />odorless fiber material. Knockouts shall be provided for <br />utility and control connections. Drain connections shall <br />be provided to accommodate indoor water runoff. <br />Compressor <br />The compressor shall be hermetically sealed, high <br />efficiency scroll compressors. Internal overcurrent and <br />over temperature protection, internal pressure relief <br />shall be standard. Other features include centrifugal oil <br />pump, low vibration and noise. <br />Refrigeration System <br />All units shall have refrigerant control. Service pressure <br />tap ports and a refrigerant line filter shall be standard. <br />Evaporator Coil Internally enhanced 3/8" OD seamless <br />copper tubing mechanically bonded to aluminum fins, <br />factory pressure and leak tested at 480 — 650 psig. All <br />units have TXV to control refrigerant flow. <br />Condenser Coil <br />The Spine Fin TM condenser coil shall be continuously <br />wrapped, corrosion resistant all aluminum with <br />minimum brazed joints. This coil is 3/8" OD seamless <br />aluminum tubing glued to a continuous aluminum fin <br />Coils are lab tested to withstand 2.000 pounds of <br />pressure per square inch. The outdoor coil provides <br />low airflow resistance and efficient heat transfer. The <br />coil is protected on all four sides by louvered panels. <br />Indoor Air Fan <br />Constant Torgue, forward -curved, centrifugal wheel in <br />a Composite Vortica ® Blower housing. Motor shall <br />have thermal overload protection and permanently <br />lubricated motor bearings. Motor/blower assembly <br />isolated from unit with rubber mounts. <br />Outdoor Fan <br />One direct -drive, statically and dynamically balanced <br />propeller fan shall be used in a draw -through vertical <br />discharge configuration. Permanently lubricated <br />weather proof motor shall have built-in thermal <br />overload protection. <br />System Controls <br />System controls include condenser fan, evaporator fan <br />and compressor contactors. <br />Accessories Roof Curb <br />The roof curb shall be designed to mate with the unit <br />and provide support and complete weathertight <br />installation when properly installed. Adhesive back <br />polyurethane sealing strips shall be provided to ensure <br />an airtight seal between supply and return openings of <br />the curb and unit. The roof curb design allows field <br />fabricated ductwork to be connected directly to the <br />curb. Curb ships knocked down for field assembly, and <br />includes factory installed wood nailer strips. <br />Electric Heaters <br />Each heater assembly shall include power supply <br />fusing if over 48 amps, automatic resetting limit <br />switches and heat limiters for thermal protection. <br />Heaters shall be provided with polarized plugs for quick <br />connection to unit low voltage wiring. Electric heat <br />modules shall be UL listed. <br />Single Source Power Entry <br />This accessory when used with electric heat accessory <br />shall allow single source power connection to unit and <br />heater combination. Single source power entry kits <br />shall have specific matching heater(s). Kit shall include <br />high voltage terminal blocks, fuse blocks and fuses, cut - <br />to -length interconnecting wiring, and junction box (if <br />required) to provide power sources with fuse <br />protection as required for both the unit and accessory <br />heater. Kit components shall install within the heater <br />cabinet in the heater access section. Single source <br />branch power circuit shall be protected and wired in <br />accordance with local codes. <br />12 4WCC4036A-SUB-1 E-EN <br />
The URL can be used to link to this page
Your browser does not support the video tag.