My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2023-04-05
>
Address Records
>
RUCKER AVE
>
3020
>
SNO CO HEALTH DISTRICT
>
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2023-04-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2023 8:38:33 AM
Creation date
4/3/2023 9:52:10 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3020
Tenant Name
SNO CO HEALTH DISTRICT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />Project: <br />Snohomish Health District - 2018 WSEC <br />3020 Rucker Ave <br />Everett, WA 98201 <br />Date: 2022-12-19 <br />Applies <br />Code Section <br />Code Provision <br />Compliance Information Required In Permit <br />Location in <br />Building Department <br />Documentation <br />Documents <br />Notes <br />SCOPE <br />C103.1 <br />Construction <br />For a shell & core or tenant space (first build - <br />documents - General <br />out) project, indicate if there is no mechanical <br />scope included in the project. <br />NA <br />C103.1 <br />Construction <br />For an alteration project, indicate if there is <br />No Mechanical Scope <br />documents - General <br />no mechanical scope included in the project. <br />- Replacement <br />PERFORMANCE CRITERIA & SYSTEM DESIGN <br />NA <br />C403.1 <br />Exempt process <br />Identify equipment used by manufacturing, <br />equipment <br />industrial or commercial processes that are <br />not for space conditioning or maintaining <br />comfort and amentities for occupants; identify <br />provisions applicable to this equipment per <br />C403.1 exception <br />C403.1.1 <br />HVAC total system <br />For systems serving office, retail, library or <br />performance ratio <br />education occupancies, provide a TSPR report <br />(TSPR) <br />that demonstrates the proposed design ratio is <br />equal to or greater than the standard reference <br />design ratio, or exception applied <br />YES <br />C403.1.2 <br />Calculation of heating <br />Provide load calculations performed per <br />and cooling loads <br />ASHRAE Std 183 or equivalent, using design <br />parameters per C302 and Appendix C; <br />include load adjustments to account for <br />energy recovery <br />NA <br />C403.1.3 <br />Data centers <br />Provide documentation that demonstrates that <br />data center systems comply with the <br />maximum allowed Design MLC and <br />Annualized MLC per ASHRAE 90.4 with <br />2018 WSEC adjustments per climate zone <br />NA <br />C403.2.1 <br />Zone isolation <br />If there are HVAC zones that are intended to <br />C403.4.2.2 <br />be occupied non -simultaneously, identify <br />isolation zone areas on plans; if multiple zones <br />intended to be occupied simultanteously will <br />be combined into a single isolation zone, <br />include on plans that the combined zone area <br />does not exceed 25,000 sf and does not <br />include more than one floor; or exception <br />applied <br />NA <br />Indicate locations of associated zone isolation <br />dampers in HVAC distribution system <br />NA <br />Refer to HVAC Controls section in <br />Requirements List for applicable automatic <br />setback and shutdown controls requirements <br />EQUIPMENT SELECTION & PERFORMANCE <br />Page 1125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.