Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2022 NEEA, All rights reserved <br />The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />NA <br />C403.4.1.6 <br />Door switches for <br />Where doors open to the outdoors from a <br />HVAC system <br />conditioned space, indicate automatic controls <br />thermostatic control <br />configured to setback the HVAC system(s) <br />when the door is open for > 5 minutes; <br />indicate method of HVAC system setback <br />control (turns off the HVAC system or resets <br />the hearing setpoint to 55°F and cooling <br />setpoint to 85°F), or exception applied <br />NA <br />C403.4.2 <br />Automatic setback <br />Indicate zone thermostatic controls configured <br />C403.4.2.1 <br />and shutdown <br />with required automatic setback and manual <br />C403.4.2.2 <br />override functions, setback temperatures, and <br />control method (automatic time clock or 7 day <br />programmable controls); note exceptions <br />applied <br />NA <br />C403.4.2.3 <br />Automatic (optimum) <br />Indicate all HVAC systems are provided with <br />start and stop <br />automatic start and stop controls; indicate start <br />controls are configured to adjust the <br />equipment start time as required to bring each <br />area served up to design temperature just <br />prior to scheduled occupancy; indicate stop <br />controls are configured to reduce heating <br />setpoint and increase cooling setpoint by at <br />least 2°F prior to scheduled unoccupied <br />periods <br />NA <br />C403.4.2.4 <br />Exhaust system off- <br />For exhaust systems serving conditioned <br />hour controls <br />spaces in all occupancies other than Group R, <br />indicate method of control and that controls <br />are configured to turn exhaust systems on and <br />off in concert with the ventilation air systems <br />providing their make-up air, or exception <br />applied <br />NA <br />C403.4.2.5 <br />Transfer and <br />For transfer fan or mixing fan systems serving <br />destratification fan <br />conditioned spaces in all occupancies other <br />system off -hour <br />than Group R, indicate method of control and <br />controls <br />that controls are configured to turn fans on <br />and off in concert with the associated HVAC <br />systems, or exception applied <br />NA <br />C403.4.7 <br />Combustion heating <br />For combustion heating equipment other than <br />equipment <br />boilers or radiant heaters with output capacity <br />> 225,000 Btu/h, indicate modulating or <br />staged combustion control <br />NA <br />C403.4.7.1 <br />Combustion <br />Indicate controls that are configured to limit <br />decorative vented <br />operation of combustion appliance, fireplace <br />appliance, <br />and fire pit to < 1 hour without override, or <br />combustion fireplace <br />that occupancy sensor controls are provided <br />and fire pit controls <br />Page 11125 <br />