• 0 <br /> Nicol Diedrich <br /> Plan Check Number: B2106-016, First Building Review <br /> August 31, 2021 <br /> Structural <br /> Plans should provide a guardrail detail. Guards and handrails should be able to withstand a <br /> uniform load of 50 lbs/ft or a concentrated load of 200 lbs placed at the top of the handrail or <br /> guard. Table R301.5 <br /> . Plans should show a detail for the construction of the interior and exterior stairs. Connections <br /> should be specified between all framing members. <br /> Provide a nailing schedule on the drawings to show the minimum fastening requirements for <br /> ,� the wood framing. Refer to IRC Table R602.3 (1) and list applicable connections on the <br /> drawings. A schedule should be provided listing the type of connections, and the type and <br /> umber of fasteners for each connection. <br /> /1. See Structural Calculations Page 5. <br /> a. Living/Stair beam is specified as a PSL beam, but plans specify LVL. <br /> b. The calculation does not show the 4-foot cantilever as shown on Sheet 3. Total <br /> length of the beam is about 18 feet 6 inches. <br /> c. Sheet 3 and 4 should be updated to show the same span for the beam./Structural Calculations should show calculations for the required footings. Please show the <br /> footing size is adequate at the support for the floor beams located the stairs/ Living Room. <br /> R106.1.1 <br /> . The design criteria on Sheet 4 should match the design criteria listed in the Structural <br /> Calculations. Structural Calculations specify an allowable bearing pressure of 2000 psf, but <br /> construction drawings specify 1500 psf on Sheet 4. Also, active pressures seem to differ <br /> between calculations and drawings. R106.1.1 <br /> 7 See Sheet 3 and 4. Plans should specify post sizes and top/bottom connections. See posts for <br /> roof and floor beams. Detail "Detail Typ Post and Beam on Footing"on Sheet 4 should specify <br /> the type of positive connection to the footing. R106.1.1 <br /> /See Sheet 4, 8, and 10. It appears that new footings are surcharging the existing basement <br /> retaining wall. Please provide structural calculations or provide a new detail showing the new <br /> footings deep enough so they are not surcharging the existing retaining wall. R106.1.1 <br /> . Plans should show how trusses and rafters are connected and tied down to bearing walls. Roof <br /> assemblies should have uplift resistance according to Section R802.11.1.1 and R802.11.1.2. <br /> (1-0. <br /> Plans should show how ceiling joists/collar ties are connected to roof rafters. R106.1.1. <br /> . See Sheet 1, 2, 3, and 6. It appears that the ridge beam spans from the exterior wall to interior <br /> bearing wall and elevations show a half-hip roof. Please provide a roof framing detail ofthe <br /> ridge beam bearing at the exterior wall where the half-hip roof occurs. R106.1.1 <br /> O3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of—4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.