Laserfiche WebLink
SOLAR MODULE SPECIFICATIONS VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX �( <br /> MANUFACTURER/MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) Lumio <br /> VMP 37.13 V FOR BRANCH CIRCUIT #1 OF 8 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.30% SMART ENERGY TODAY <br /> IMP 10.77 A FOR BRANCH CIRCUIT #2 OF 6 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.18% (SET) <br /> 1550 DIGITAL DR,LEHI,UT <br /> VOC 45.3 V VOLTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX 84043,USA <br /> ISC 11.14 A VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> TEMP. COEFF. VOC -0.27%/K = (1.21 AMP X 8) X (0.00205 OHMS/FT) X (47 FT X 2) <br /> PTC RATING 376.55 W <br /> = 9.68 AMPS X 0.00205 OHMS/FT) X 94 FT <br /> MODULE DIMENSION 74"(L)x 41.1"(W) <br /> PANEL WATTAGE 400 W = 1.87 VOLTS SYSTEM INFO <br /> %VRISE = 1.87 VOLTS = 240 VOLTS = 0.78% (14)Q CELLS <br /> INVERTER SPECIFICATIONS THE VOLTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX IS 0.78% Q.PEAKDUOBLKML-G10+ <br /> MANUFACTURER/MODEL ENPHASE IQ8PLUS-72-2-US (240V) (aoow) <br /> VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE NON FUSED AC DISCONNECT (14)ENPHASE <br /> MAX DC SHORT CIRCUIT CURRENT 15 A IQ8PLUS-72-2-US(240V) <br /> CONTINUOUS OUTPUT CURRENT 1.21 A VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) DC SYSTEM SIZE:5.600 kW <br /> AC SYSTEM SIZE:4.200 kWAC <br /> AMBIENT TEMPERATURE SPECS = (1.21 AMP X 14) X (0.00051 OHMS/FT) X (5 FT X 2) <br /> RECORD LOW TEMP _5°C = 16.94 AMPS X 0.00051 OHMS/FT) X 10 FT <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C = 0.09 VOLTS REVISIONS <br /> CONDUIT HEIGHT 7/8" %VRISE = 0.09 VOLTS - 240 VOLTS = 0.04% DESCRIPTION DATE REV <br /> ROOF TOP TEMP 90°C THE VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE NON FUSED AC DISCONNECT IS 0.04% <br /> CONDUCTOR TEMPERATURE RATE 48°C VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> PERCENT OF VALUES NUMBER OF CURRENT CARRYING = (1.21 AMP X 14) X (0.00051 OHMS/FT) X (5 FT X 2) PROJECT NAME&ADDRESS <br /> CONDUCTORS IN EMT <br /> 0.80 4-6 = 16.94 AMPS X 0.00051 OHMS/FT) X 10 FT <br /> 0.70 7-9 = 0.09 VOLTS <br /> 0.50 10-20 %VRISE = 0.09 VOLTS -- 240 VOLTS = 0.04% <br /> THE VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE MSP IS 0.04% o <br /> N <br /> 00 <br /> TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS Q o <br /> 0 <br /> 0.3% + 0.78% + 0.04% + 0.04% = 1.16% w o <br /> W � <br /> U <br /> 0 <br /> Z W W <br /> W 0 > <br /> d W W o <br /> > it <br /> 07 Q Z <br /> Q Q <br /> LL <br /> CD <br /> N <br /> d7 <br /> DATE: 10/26/2022 <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & NOTES <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV 8 <br />