My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2113 HOYT AVE 2023-04-28
>
Address Records
>
HOYT AVE
>
2113
>
2113 HOYT AVE 2023-04-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2023 8:28:37 AM
Creation date
4/6/2023 7:01:11 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2113
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOLAR MODULE SPECIFICATIONS VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX �( <br /> MANUFACTURER/MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) Lumio <br /> VMP 37.13 V FOR BRANCH CIRCUIT #1 OF 10 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.71% SMART ENERGY TODAY <br /> IMP 10.77 A FOR BRANCH CIRCUIT #2 OF 10 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.71% (SET) <br /> 1550 DIGITAL DR,LEHI,UT <br /> VOC 45.3 V FOR BRANCH CIRCUIT #3 OF 9 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.58% 84043,USA <br /> ISC 11.14 A FOR BRANCH CIRCUIT #4 OF 3 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.05% <br /> TEMP. COEFF. VOC -0.27%/K VOLTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX <br /> PTC RATING 376.55 W VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> MODULE DIMENSION 74"(L)x 41.1"(W) <br /> PANEL WATTAGE 40o w = (1.21 AMP X 10) X (0.00205 OHMS/FT) X (72 FTX 2) SYSTEM INFO <br /> = 12.10 AMPS X 0.00205 OHMS/FT) X 144 FT (32)QCELLS <br /> INVERTER SPECIFICATIONS Q.PEAK DUO BLK ML-G10+ <br /> MANUFACTURER/MODEL ENPHASE IQ8PLUS-72-2-US (240V) %VRISE = 3.57 VOLTS = 240 VOLTS = 1.49% (32)ENPHASE <br /> MAX DC SHORT CIRCUIT CURRENT 15 A IQ8PLUS-72-2-US(240V) <br /> CONTINUOUS OUTPUT CURRENT 1.21 A THE VOLTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX IS 1.49% DC SYSTEM SIZE:12.800kWDC <br /> AMBIENT TEMPERATURE SPECS VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE FUSED AC DISCONNECT AC SYSTEM SIZE:9.600kWAC <br /> RECORD LOW TEMP -5°C VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C = (1.21 AMP X 32) X (0.00051 OHMS/FT) X (5 FT X 2) REVISIONS <br /> CONDUIT HEIGHT 7/8" = 38.72 AMPS X 0.00051 OHMS/FT) X 10 FT DESCRIPTION DATE REV <br /> ROOF TOP TEMP 90°C = 0.20 VOLTS REVISION 10/28/2022 1 A <br /> CONDUCTOR TEMPERATURE RATE 48°C %VRISE = 0.20 VOLTS - 240 VOLTS = 0.08% <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K THE VOLTAGE RISE FROM THE IQ COMBINER BOX TO THE FUSED AC DISCONNECT IS 0.08% <br /> PERCENT OF VALUES NUMBER OF CURRENT CARRYING VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP PROJECT NAME&ADDRESS <br /> CONDUCTORS IN EMT <br /> 0.80 4-6 VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> 0.70 7-9 = (1.21 AMP X 32) X (0.00051 OHMS/FT) X (10 FT X 2) Q <br /> 0.50 10-20 = 38.72 AMPS X 0.00051 OHMS/FT) X 20 FT D <br /> = 0.39 VOLTS 17 <br /> 0 <br /> %VRISE = 0.39 VOLTS -- 240 VOLTS = 0.16% 00 <br /> THE VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP IS 0.16% Q CD <br /> Y CD <br /> TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS J ui � <br /> Lu <br /> 0.71% + 1.49% + 0.08% + 0.16% = 2.44% 00 w0')o w <br /> = w w CD <br /> _U LLj <br /> Q Z <br /> 0- <br /> < <br /> O <br /> co <br /> N <br /> DATE: 10/28/2022 <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & NOTES <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.