0 TRANE, <br /> Model Number Description - 3-10Ton <br /> W S C 1 2 0 E 4 R 0 A <br /> 1 2 3 4 5 6 7 8 9 10 11 12 13 <br /> Digit 1 - UnitType Enthalpy 0-100%with Barometric Digit 22 - Refrigeration System <br /> W Packaged Heat Pump3 Reliefs Option <br /> K Low Leak Economizer with 0 Standard Refrigeration S stem$ <br /> Digit 2 - Efficiency Barometric Relief g y <br /> S Standard Efficiency M Low Leak Economizer with Reference Digit 23 - Refrigeration Controls <br /> Digit 3 -Airflow Enthalpy with Barometric Relief 0 No Refrigeration Control3 <br /> P Low Leak Economizer with 1 FrostatTm 12 <br /> C Convertible Comparative Enthalpy with <br /> 2 Crankcase Heater <br /> Digit 4,5,6 - Nominal Gross Barometric Relief 3 Frostat and Crankcase Heater12 <br /> Cooling Capacity (MBh) Digit 15 - Supply Fan/Drive Type/ Digit 24- Smoke Detector <br /> 036 3Ton Motor 0 No Smoke Detector <br /> 048 4Ton 0 Standard Drive4 A Return Air Smoke Detectors <br /> 060 5Ton 1 Oversized Motor B Supply Air Smoke Detector <br /> 072 6Ton 2 Optional Belt Drive Motor C Supply and Return Air Smoke <br /> 090 71/2Ton,Single Compressor 6 Single Zone Variable Air Detectors9 <br /> 120 10Ton Volume(SZVAV)15 D Plenum Smoke Detector <br /> Digit 7 - Major Design Sequence 7 Multi-Speed Indoor Fan13 Digit 25 - System Monitoring <br /> E R-410A Refrigerant Digit 16 - Hinged Service Access/ Controls <br /> Digit 8 -Voltage Selection Filters 0 No Monitoring Control <br /> 3 208-230/60/3 0 Standard Panels/Standard Filters 1 Clogged Filter Switch <br /> 4 460/60/3 A Hinged Access Panels/Standard 2 Fan Failure Switch <br /> W 575/60/3 Filters 3 Discharge Air Sensing Tube <br /> B Standard Panels/2" MERV 8 Filters 4 Clogged Filter Switch and Fan <br /> Digit 9 - Unit Controls C Hinged Access Panels/2" MERV 8 Fail Switch <br /> R ReliaTeITM Microprocessor Filters 5 Clogged Filter Switch and Discharge <br /> D Standard Panels/2" MERV 13 Filters Air Sensing Tube <br /> Digit 10 - Heating Capacity E Hinged Access Panels/2" MERV 13 6 Fan Fail Switch and Discharge Air <br /> 0 No Electric Heat Filters Sensing Tube <br /> A 5 kW(1 phase)' Digit 17 - Condenser Coil 7 Clogged Filter and Fan Fail Switches <br /> B 6 kW and Discharge Air Sensing Tube <br /> C 9 kW Protection A Condensate Drain Pan Overflow <br /> E 12 kW 0 Standard Coil Switch <br /> G 18 kW 1 Standard Coil with Hail Guard B Clogged Filter Switch and <br /> J 23 kW 2 Black Epoxy Pre-Coated Condenser Condensate Drain Pan Overflow <br /> K 27 kW Coil Switch <br /> N 36 kW 3 Black Epoxy Pre-Coated C Fan Failure Switch and Condensate <br /> P 54 kW Condenser Coil with Hail Guard Drain Pan Overflow Switch <br /> Digit 11 -Minor Design Sequence Digit 18 -Through-the-Base D Discharge Air Sensing and <br /> A First Sequence Provisions Condensate Drain Pan Overflow <br /> Switch <br /> Digit 12,13 - Service Sequence 0 NoThrough-the-Base Provisions E Clogged Filter Switch,Fan Failure <br /> ** Factory Assigned A Through-the-Base Electrics Switch and Condensate Drain Pan <br /> Digit 19 - Disconnect/Circuit Overflow Switch <br /> Digit 14- Fresh Air Selection F Clogged Filter Switch,Discharge <br /> Breaker (three-phase only) Tube and Condensate Air Sensin <br /> 0 No Fresh Air Sensing <br /> Tube <br /> Manual Outside Air Damper 0-50%2 0 No Disconnect/No Circuit Breaker Drain Pan Overflow Switch <br /> B Motorized Outside Air Damper 1 Unit Mounted Non-Fused G Fan Failure Switch,Discharge Air <br /> 0-50%11 Disconnects Sensing Tube and Condensate <br /> C Economizer,Dry Bulb 0-100% 2 Unit Mounted Circuit Breaker6 Drain Pan Overflow Switch <br /> without Barometric Reliefs Digit 20 - Convenience Outlet H Clogged Filter Switch,Fan Failure <br /> D Economizer,Dry Bulb 0-100% 0 No Convenience Outlet Switch,Discharge Air Sensing <br /> with Barometric Reliefs and Condensate Drain Pan Overflow <br /> E Economizer,Reference Enthalpy A Unpowered Convenience Outlet Switch <br /> 0-100%without Barometric Reliefs B Powered Convenience Outlet <br /> F Economizer,Reference Enthalpy (three-phase only) <br /> 0-100%with Barometric Reliefs Digit 21 - Communications <br /> G Economizer,Comparative Options <br /> Enthalpy 0-100%without 0 No Communications Interface <br /> Barometric Reliefs 1 Trane®Communications Interface <br /> H Economizer,Comparative 2 LonTalk®Communications Interface <br /> 6 BACnet(O)Communications Interface <br /> 20 PKGP-PRC013K-EN <br />