Laserfiche WebLink
TRNYE <br /> General Data <br /> Table 3. General data-6-10 tons-standard efficiency(continued) <br /> 6 Tons 71/2 Tons 10 Tons <br /> WSC072E3,4,W WSC090E3,4,W WSC120E3,4,W <br /> Outdoor Coil-Type Lanced Lanced Lanced <br /> Configuration Full Face Full Face Intertwined <br /> Tube Size(in.) 0.3125 0.3125 0.3125 <br /> Face Area (sq.ft.) 17.00 19.83 25.56 <br /> Rows/FPI 3/16 3/16 3/16 <br /> Refrigerant Control Thermal Expansion Valve Thermal Expansion Valve Thermal Expansion Valve <br /> Indoor Coil -Type Lanced Lanced Lanced <br /> Configuration Full Face Full Face Intertwined <br /> Tube Size(in.) 0.3125 0.3125 0.3125 <br /> Face Area (sq.ft.) 9.89 12.36 16.65 <br /> Rows/FPI 4/16 3/16 4/16 <br /> Refrigerant Control Orifice Orifice Orifice <br /> Drain Connection Number/Size(in.) 1 3/4 NPT 1 3/4 NPT 1 3/4 NPT <br /> Outdoor Fan-Type Propeller Propeller Propeller <br /> Number Used/Diameter(in.) 1/26 1/26 1/30 <br /> Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 <br /> cfm 5,800 6,200 6,900 <br /> Motor hp 0.70 0.75 0.75 <br /> Motor rpm 1,100 1,100 1,100 <br /> Indoor Fan -Type FC Centrifugal FC Centrifugal BC Plenum <br /> Number Used/Diameter(in.)/Width (in.) 1/12x12 1/15 x 15 1/19.7 x 15 <br /> Drive Type/No. Speeds/rpm Belt/Variable/1,750 Belt/Variable/1,750 Direct/Variable(f) <br /> Motor hp(Standard/Oversized) 1.0/2.0 1.0/3.0 3.75/— <br /> Motor Frame Size(Standard/Oversized) 56/56 56/56 —/— <br /> Filters(9)-Type Furnished Throwaway Throwaway Throwaway <br /> Number Size Recommended (4) 16x25x2 (4) 20x25x2 (3) 20x25x2 <br /> (2) 20x3Ox2 <br /> Refrigerant Charge(h) <br /> Pounds of R-410A 12.00 13.80 9.75/9.31 <br /> (a)Cooling performance is rated at 95°F ambient,80°F entering dry bulb,67°F entering wet bulb.Gross capacity does not include the effect of fan motor <br /> heat.AHRI capacity is net and includes the effect of fan motor heat.Units are suitable for operation to±20%of nominal cfm.Units are certified in <br /> accordance with the Unitary Air-Conditioner Equipment certification program,which is based on AHRI Standard 340/360. <br /> (b)EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures. <br /> (c)Integrated Efficiency Ratio(IEER)is rated in accordance with AHRI Standard 340/360.The IEER rating requires that the unit efficiency be determined <br /> at 100%,75%,50%and 25%load(net capacity)at the specified in AHRI Standard. <br /> (d)Heating performance is rated at 47°F ambient with 43°F wet bulb,70°F entering dry bulb,60°F entering wet bulb. High Temp. Btuh Rating includes <br /> the effect of fan motor heat.Units are suitable for operation to±20%of nominal cfm.Units are certified in accordance with the Unitary Air-Conditioner <br /> Equipment certification program,which is based on AHRI Standard 340/360. <br /> (e)Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270. For additional information refer to Table 28,p.45. <br /> (f) For multispeed direct drive rpm WSC values,reference Table 27,p.45. <br /> (g)Optional 2"MERV 8 and MERV 13 filters also available. <br /> (h)Refrigerant charge is an approximate value. For a more precise value,see unit nameplate and service instructions. <br /> PKGP-PRC013K-EN 25 <br />