Laserfiche WebLink
UTRNYE <br /> Performance Data <br /> Table 9. Gross cooling capacities 10 tons standard efficiency-three phase WSC120E3,4,W <br /> Ambient Temperature <br /> 85 95 105 <br /> Air Ent Entering Wet Bulb <br /> Flow DB 61 67 73 61 67 73 61 67 73 <br /> cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC <br /> 3200 75 117.3 95.4 124.8 73.0 133.6 38.6 110.1 90.3 117.9 69.5 127.0 36.7 101.7 84.2 109.7 65.0 119.1 33.9 <br /> 3200 80 120.9 110.2 126.8 92.8 134.1 63.4 113.9 105.1 120.2 89.3 127.8 61.5 105.7 99.1 112.3 84.8 120.2 58.6 <br /> 3200 85 125.4 121.7 129.8 109.2 135.6 84.8 118.7 116.5 123.5 105.7 129.6 82.9 110.8 110.5 115.8 101.2 122.3 80.0 <br /> 3200 90 130.9 129.7 133.8 122.2 138.1 102.8 124.5 124.5 127.7 118.7 132.3 100.8 116.8 116.8 120.4 114.2 125.3 98.0 <br /> 3600 75 120.9 98.7 127.6 75.2 135.6 39.7 113.9 93.8 120.8 71.9 129.2 38.0 105.6 88.0 112.9 67.6 121.5 35.4 <br /> 3600 80 124.7 114.0 129.9 95.4 136.4 64.9 118.0 109.1 123.4 92.1 130.3 63.2 110.0 103.2 115.7 87.9 122.9 60.6 <br /> 3600 85 129.5 125.9 133.2 112.3 138.2 86.8 123.1 121.0 127.0 109.0 132.4 85.1 115.3 115.1 119.6 104.7 125.2 82.4 <br /> 3600 90 135.3 134.4 137.5 125.8 141.0 105.3 129.1 129.1 131.6 122.4 135.4 103.5 121.6 121.6 124.4 118.2 128.6 100.8 <br /> 4000 75 123.8 101.7 129.6 77.1 136.9 40.5 116.9 97.0 123.1 74.0 130.7 39.0 108.8 91.4 115.3 69.9 123.2 36.5 <br /> 4000 80 127.9 117.4 132.3 97.8 138.0 66.2 121.3 112.7 126.0 94.7 132.1 64.7 113.5 107.1 118.5 90.6 124.8 62.2 <br /> 4000 85 133.0 129.8 135.9 115.1 140.1 88.5 126.7 125.1 129.9 112.0 134.4 87.0 119.1 119.1 122.6 107.9 127.5 84.5 <br /> 4000 90 139.1 138.8 140.4 129.1 143.2 107.4 133.0 133.0 134.7 125.9 137.8 105.9 125.8 125.8 127.7 121.8 131.1 103.4 <br /> 4400 75 125.9 104.4 131.0 78.6 137.5 40.9 119.3 99.9 124.7 75.7 131.4 39.6 111.4 94.5 117.0 71.9 124.1 37.4 <br /> 4400 80 130.3 120.6 133.9 99.8 138.9 67.1 124.0 116.1 127.8 96.9 133.1 65.8 116.3 110.6 120.5 93.1 126.1 63.5 <br /> 4400 85 135.7 133.4 137.8 117.6 141.3 89.9 129.6 128.9 132.0 114.7 135.8 88.5 122.3 122.3 124.9 110.8 129.0 86.3 <br /> 4400 90 142.1 142.1 142.7 132.0 144.7 109.2 136.3 136.3 137.2 129.1 139.4 107.9 129.2 129.2 130.4 125.2 132.9 105.6 <br /> 4800 75 127.4 106.8 131.7 79.9 137.4 41.1 120.9 102.5 125.5 77.2 131.5 40.0 113.2 97.2 118.1 73.6 124.4 38.0 <br /> 4800 80 132.1 123.4 134.9 101.5 139.1 67.7 125.9 119.1 129.0 98.8 133.5 66.6 118.4 113.9 121.8 95.2 126.6 64.6 <br /> 4800 85 137.8 136.7 139.1 119.8 141.8 90.9 131.8 131.8 133.4 117.1 136.4 89.8 124.7 124.7 126.6 113.4 129.9 87.8 <br /> 4800 90 144.4 144.4 144.2 134.7 145.4 110.8 138.8 138.8 138.9 131.9 140.4 109.6 131.9 131.9 132.3 128.3 134.1 107.6 <br /> Ambient Temperature <br /> 115 1125 <br /> Air Ent Entering Wet Bulb <br /> Flow DB 61 67 73 61 67 73 <br /> cfm (F) MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC <br /> 3200 75 91.9 77.3 100.3 59.6 110.0 30.1 80.9 69.4 89.6 53.3 99.6 25.4 <br /> 3200 80 96.3 92.1 103.1 79.4 111.4 54.8 85.6 84.2 92.7 73.1 101.2 50.1 <br /> 3200 85 101.6 101.6 106.9 95.8 113.7 76.2 91.1 91.1 96.8 89.5 103.8 71.4 <br /> 3200 90 107.9 107.9 111.7 108.8 117.0 94.1 101.9 101.9 101.9 101.9 107.4 89.4 <br /> 3600 75 96.1 81.2 103.6 62.5 112.6 31.8 85.2 73.5 93.1 56.4 102.4 27.3 <br /> 3600 80 100.7 96.4 106.8 82.7 114.2 57.0 90.2 88.7 96.5 76.6 104.3 52.5 <br /> 3600 85 106.3 106.3 110.9 99.5 116.8 78.8 96.0 96.0 100.9 93.4 107.2 74.3 <br /> 3600 90 112.9 112.9 116.0 113.0 120.4 97.2 106.3 106.3 106.3 106.3 111.0 92.7 <br /> 4000 75 99.5 84.8 106.2 64.9 114.4 33.2 88.8 77.3 95.9 59.1 104.4 28.9 <br /> 4000 80 104.4 100.5 109.7 85.6 116.4 58.8 94.1 93.0 99.6 79.7 106.6 54.5 <br /> 4000 85 110.3 110.3 114.1 102.9 119.3 81.1 100.2 100.2 104.3 97.0 109.8 76.8 <br /> 4000 90 117.2 117.2 119.5 116.8 123.2 100.0 110.0 110.0 110.0 110.0 114.0 95.6 <br /> 4400 75 102.2 88.1 108.2 67.1 115.6 34.2 91.7 80.8 98.0 61.4 105.7 30.1 <br /> 4400 80 107.4 104.3 111.9 88.3 117.8 60.4 97.2 97.0 102.0 82.6 108.2 56.2 <br /> 4400 85 113.6 113.6 116.6 106.0 121.0 83.1 103.7 103.7 107.0 100.3 111.7 79.0 <br /> 4400 90 121.1 121.1 122.3 120.4 125.2 102.4 113.0 113.0 113.0 113.0 116.2 98.3 <br /> 4800 75 104.2 91.1 109.4 69.0 116.0 35.0 93.9 84.0 99.4 63.5 106.3 31.1 <br /> 4800 80 109.7 107.7 113.4 90.6 118.5 61.6 99.7 99.7 103.7 85.1 109.1 57.7 <br /> 4800 85 116.2 116.2 118.4 108.8 122.0 84.8 106.5 106.5 109.0 103.3 112.9 80.8 <br /> 4800 90 123.1 123.1 124.4 123.7 126.5 104.6 115.2 115.2 115.2 115.2 117.7 100.6 <br /> Note: <br /> 1. All capacities shown are gross and have not considered indoor fan heat.To obtain NET cooling capacity <br /> subtract indoor fan heat. For indoor fan heat formula,refer to appropriate airflow table notes. <br /> 2. MBh =Total Gross Capacity <br /> 3. SHC=Sensible Heat Capacity <br /> PKGP-PRC013K-EN 31 <br />