My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10217 19TH AVE SE 2023-04-28
>
Address Records
>
19TH AVE SE
>
10217
>
10217 19TH AVE SE 2023-04-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2023 10:42:11 AM
Creation date
4/6/2023 8:16:44 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10217
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 TRME" <br /> Mechanical Specifications <br /> Two field installed kits are offered:CO2 sensor and wiring or CO2 sensor only.The CO2 sensor only <br /> kit should be ordered with factory installed CO2 Sensor wiring.Factory installed CO2 sensor wiring <br /> saves set-up time and ensures proper unit connections for the CO2 sensor. <br /> High Static Drive <br /> The high static drive option shall allowthe standard motorto operate with improved external static <br /> capabilities. <br /> Low Leak Economizer <br /> This accessory meets low leak requirements forASHRAE 90.1, IECC,and CATitle 24 standards (3 <br /> cfm/ft^2@1"wg exterior air,4 cfm/ft^2@1"wg return air).This option allows 100%outdoor air <br /> supply from 0-100% modulating dampers and is standard with barometric relief. It can be paired <br /> with powered exhaust for additional building pressure relief.Available on downflow units only. <br /> Manual Outside Air Damper <br /> This rain hood and screen shall provide up to 50 percent outside air. <br /> Motorized Outside Air Damper <br /> Manually set outdoor air dampers shall provide up to 50 percent outside air.Once set,outdoor air <br /> dampers shall open to set position when indoorfan starts.The damper shall close to the full closed <br /> position when indoor fan shuts down. <br /> Powered Exhaust <br /> The powered exhaust,available for 6-10 ton units,shall provide exhaust of return air,when using <br /> an economizer,to maintain better building pressurization. <br /> Programmable Night Setback <br /> Auto or manual changeover with seven-day programming. Keyboard selection of Heat,Cool,Fan, <br /> Auto, or On.All programmable sensors have System On, Heat, Cool, Service LED/indicators as <br /> standard.Night Setback Sensors have one(1)Occupied,one(1)Un-occupied,and one(1)Override <br /> program per day. <br /> Remote Potentiometer <br /> The minimum position setting of the economizer shall be adjusted with this accessory. <br /> Roof Curb <br /> The roof curb shall be designed to mate with the unit's downflow supply and return and provide <br /> support and a water tight installation when installed properly.The roof curb design shall allow <br /> field-fabricated rectangular supply/return ductworkto be connected directlyto the curb.Curb shall <br /> be shipped knocked down for field assembly and shall include wood nailer strips. <br /> Thermostat <br /> Two stage heating and cooling operation or one stage heating and cooling shall be available in <br /> either manual or automatic changeover.Automatic programmable electronic with night set back <br /> shall also be available. <br /> Ventilation Override Accessory <br /> With the Ventilation Override Accessory installed,the unit can be set to transition up to 3 different <br /> pre-programmed sequences for Smoke Purge,Pressurization,and Exhaust.The transition occurs <br /> when a binary input on the RTOM is closed (shorted).This would typically be a hard wired relay <br /> output from a smoke detector or fire control panel.The ventilation override accessory shall be <br /> available as field installed. <br /> PKGP-PRC013K-EN 85 <br />
The URL can be used to link to this page
Your browser does not support the video tag.