Sign Design Based On 2015 IBC ANALYSIS <br /> Velocity pressure <br /> , _... qz=0.00256 K,Kn Ka Vi = 22.38 <br /> Job# JTS_208420 where: <br /> Project Panda Express-Menuboard - q„=velocity pressure at height h.(Eq.29.3-1,page 249) <br /> L._ 7'-33/8" -I Job Location 11610 Evergreen Way K"=velocity pressure egosurecoefficient = 0.85 <br /> Everette,WA evaluated at height above gRnd.level,h (Tab.29.3-1, page 251) <br /> Ku=wind directionality factor.(Tab.26.6-1,page 194) = 0.85 <br /> T INPUT DATA <br /> i:i f ¢: Wind Force Case A:resultant force through geometric center <br /> e s Exposure category(B,C or D) = <br /> C <br /> Max horizontal wind pressure= p=qs GC,= = 30 <br /> j.' € c: Risk Category = II where: ,G=gust effect factor.(Sec.26.9,page 198). = 0.85 <br /> Ultimate Design Windspeed VuLTI = 110 MPH jC,=net force coefficient.(Fig.29.4-1,page 252) 1.59 <br /> I _1 Topographic factor Kn = 1 Flat A,=Bs=the gross area = 29.77 <br /> SIGN CABINET Height of the sign h = 5.58 FT Estimated sign cabinet weight = 180 <br /> Ei <br /> I' Average Vertical dimension(for wall,s=h) s' = r 4.09 FT <br /> 3'-11 3/8 Horizontal dimension B = 7.28 FT DESIGN SUMMARY <br /> , Dimension of return corner L, = 0.75 FT Allowable Stress Design Wind Factor= 0.60 <br /> i , Design Wind Pressure= 0.6 x p= 18.20 <br /> 5•-T, I I' I Design Windforce,F = 18.20 x As= 0.54 <br /> j -- Moment Arm= 3.51 <br /> Design Moment = F x Moment Arm= 1.90 <br /> I <br /> I - 14 1/2" - Footing Design(Nonconstrained) <br /> r -- <br /> t -. -- ._ - _ _1 - Diameter=' 2.00 FT <br /> f ! Soil Pressure= 100.00 PSF/FT <br /> 11 3/8"DIA. 283.33 PSF <br /> BOLT CIRCLE St <br /> 1'-7 5/8" _ __HSS 4"X 4"X 1/4" A= 2.24 FT <br /> STL SQ.HSS EMBED.= 4.25 FT T <br /> iIA <br /> - - <br /> HSS 4"X 4"X 1/4" <br /> STL SQ.HSS r 24" DIA. DEPTH=4' 3" <br /> t " a <br /> 1"DIA.,24"MIN.EMBED. <br /> TYP, Pole Design ST'L.SQ.HSS <br /> ' 1/4" GALV.ST'L ANCHOR BOLTS,TYP. Sec.Mod.Req'd. USE A500 OR.B <br /> j PL 14 1/2"DIA.,X 1"THK. S= 0.83 HSS 4"x 4"x 1/4" r S= 3.90 <br /> ST'L PLATE <br /> Anchor Design GALV.STL.ANCHOR BOLT <br /> BASE <br /> S PLATE Tension Req'd. USE F1554 GR.36 <br /> . y ,,__ j I (� T= 1426 I 1"DIA,x 24"MIN.EMBED r T= 17070 <br /> • 18"FROST DEPTH ` t=1" N.T.S. Shear Req'd. <br /> ' q . <br /> `• "er • 'es- V = 180 'V = 9110 <br /> i'.. Unity- (1426 /"17070) +" (180 /* 9110)=T0.10 <1(OK) <br /> 4'-3" <br /> L 36" H Base Plate STL.PLATE <br /> CONSOLIDATED Thickness Reqd. USE A36 <br /> II t= 0.31 I PL 141/2"Dia.,x 1"Thk.. r t. tooCONC.f'c=2500 PSI 1 1/2"--1 I 11"- - 11" -- 11" I I~1 1/2" <br /> (2)#4 TIES TOP 5" J r 1" <br /> Bolt Design GALV.STL.THRU-BOLTS <br /> #4 TIES @ 6"O.C. T - 5/8"DIA.,GALV.ST'L Tension Req'd. USE A307 <br /> TOP 24" f_ -0p 0 C © THRU-BOLTS T = 1030 5/8"DIA, rT = 6910 <br /> #4 TIES @ 12"O.C. 5" 3" TYP. Shear Req'd. <br /> - - - - - REMAINDER + _l.-.-l© QO (O 0 V = 68 r V = 3680 <br /> L (6)#6 VERTS, 1 - -- - - Unity= r(1030 I' 6910) +• (68 /P. 3680)=15.17 <1(OK) <br /> '4 i--- 24"DIA. -1 3"CLEARANCE 1" HSS 4"X 4"X 1/4" PL 36"X 5"X 5/8" <br /> TYP. ST'L PLATE <br /> 4, 1/4" ST'L SQ.HSS Match Plate STL.PLATE <br /> Thickness Req'd. USE A36 <br /> ELEVATIONpok MATCH PLATE C,T t= PL 36"x 5"x 5/8" r t= 0.63 <br /> N.T.S. (1-.1 �F t=5/8" N.T.S. fr ,®/% <br /> NOTES : ®A)pc. ik <br /> GENERAL: STEEL: WELDING ���7 CONCRETE <br /> ISP AC J4 • SIGN DESIGN IS BASED ON ADEQUATE EXISTING SUPPORT ELEMENTS. DESIGN AND FABRICATION ACCORDING TO 2015 IBC STEEL DESIGN AND CONSTRUCTION ACCORDING TO ACI 31- <br /> ®� ()V WAS/,: Cb • PROVIDE ISOLATION OF DISSIMILAR MATERIALS. - PLATE,ANGLE,CHANNEL TEE:ASTM A36 DESIGN AND FABRICATION ACCORDING TO AWS D1.1./D1.3 • COMPRESSIVE STRENGTH AT 28 DAYS,f'c=2500 PS' <br /> 4,j AtIP::. <br /> • COAT ALUMINUM IN CONTACT WITH CONCRETE WITH ZINC RICH PAINT. - WIDE FLANGE:ASTM A992 • AWS CERTIFICATION REQUIRED FOR ALL STRUCTURAL WELDERS. MINIMUM. <br /> r. - E70 XX ELECTRODE FOR SMAW PROCESS. <br /> �r J.'"• - THERE IS NO PROTECTION ZONE AS DEFINED IN AISC 341-10. • ROUND PIPE:ASTM A53 GRADE B OR EQUIVALENT. • CEMENT TYPE II OR IV.W/C RATIO 0.45 BY WEIGHT F <br /> + : t - � - E7OS XX ELECTRODE FOR GMAW PROCESS. <br /> „or� / - PROVIDE FULLY WELDED END CAPS AT EXPOSED OPEN ENDS OF • HSS ROUND,SQUARE,AND RECTANGULAR TUBE:ASTM A500 GRADE B PIER AND CAISSON <br /> �r�rr O - ER7 XX ELECTRODE FOR GTAW PROCESS. <br /> i STEEL/ALUM.TUBES,MATCH THICKNESS LIKE FOR LIKE. OR EQUIVALENT. FOOTINGS CONCRETE MUST BE POURED AGAINST <br /> ® E70T XX ELECTRODE FOR FCAW PROCESS. <br /> / SLOPE TOP OF EXPOSED FOOTING AWAY FROM DIRECT BURIAL POSTS • ALL ANCHORS BOLTS SHOULD BE:ASTM F1554 UNDISTURBED EARTH. <br /> lll.��� / ALL WELDS SHALL BE MADE WITH A FILLER METAL THAT CAN PRODUCE <br /> 52' 0, • ALL EXPOSED STEEL TO BE PRIMED&PAINTED(POWDER COAT AS AN - ALL STEEL MACHINED BOLTS SHOULD BE:ASTM A307 OR ASTM A449 WELDS THAT HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20FT-LB • MAINTAIN A MINIMUM 3"CONCRETE COVER OVER <br /> C oa ‘ r'*' _ OPTION)OR ALTERNATIVELY USE GALVANIZED STEEL. - ALL STAINLESS STEEL MACHINED BOLTS SHOULD BE:ASTM A276 AT ZERO 0°AS DETERMINED BY THE APPROPRIATE AWS A5 CLASSIFICATION EMBEDDED STEEL. <br /> �]` ANCHORS: - ALL BOLTS TO BE ZINC COATED:ASTM B633 <br /> Q TEST METHOD OR MFG'S.CERTIFICATION. <br /> TONAL `\ • BRAND NAME APPROVED POST INSTALLED ANCHORS SPECIFIED ON • DEFORMED REINFORCING REBAR:ASTM A615 GRADE 60. ALUMINUM SOIL: <br /> \V PLANS MAY BE SUBSTITUTED BY APPROVED EQUAL. ALUMINUM: DESIGN AND FABRICATION ACCORDING TO AWS D1.2.ALL WELDING IN LATERAL SOIL BEARING PER IBC CLASS 5 TABLE 1806. <br /> tiDESIGN AND FABRICATION ACCORDING TO 2015 ALUM.DESIGN MANUAL ACCORDANCE WITH THE LATEST EDITION OF THE AWS A.5.10. PSF/FT).MODIFIED PER SECTION 1806.3.4. <br /> N PLATES,ANGLES,CHANNELS,TEE,AND SQUARE TUBING:ALUMINUM FILLER ALLOYS PER TABLES M.9.1&M.9.2 OF 2015 ALUMINUM DESIGN MANUAL. <br /> • ALLOY 6061-T6 WITH 0.098 LBS PER CUBIC INCH. <br /> "...„.. <br /> DRN BY: M.L. DATE LAST REVISED: Dec 16,2020 REV.NO. REV.DATE REVISED BY PROJECT JOB t: Ex ress Menuboard Ever reen Wa Everett WA.dw <br /> www.yjinc.com SHEET TITLE: JTS_208420_PandaP _ _ g Y_ _ g <br /> J _ CHK BY: T.J. PROJ.START DATE: Dec 11,2020 1 -I-I- - PROJECT LOCATION: PANDA EXPRESS SHEET# <br /> P.O.BOX 802050 � � S �� <br /> SANTA CLARITA,CA.91380 ENUBOD REV BY: T.J. SCALE: AS SHOWN 2 -/-/-- 11610 EVERGREEN WAY <br /> TEL (661)259-0700 FAX.(661)259-0900 EVERETT.WA 1 OF <br /> plotted by:Angie Ocampo on 12.16.2020 @ 5:32 PM 3 -I-I- <br />