WWHM2 012 <br /> PROJECT REPORT <br /> Project Name: stormtank <br /> Site Name: The Landing at Port Gardner <br /> Site Address: 3632 Rucker Ave <br /> City : Everett <br /> Report Date: 9/19/2018 <br /> Gage : Everett <br /> Data Start : 1948/10/01 <br /> Data End : 2009/09/30 <br /> (adjusted) Precip Scale: 0.00 <br /> Version Date: 2018/03/02 <br /> Version : 4 .2. 14 <br /> Low Flow Threshold for POC 1 : 50 Percent of the 2 Year <br /> High Flow Threshold for POC 1: 50 year <br /> PREDEVELOPED LAND USE <br /> Name : Existing <br /> Bypass: No <br /> GroundWater: No <br /> Pervious Land Use acre <br /> C, Pasture, Flat .43 <br /> Pervious Total 0.43 <br /> Impervious Land Use acre <br /> Impervious Total 0 <br /> Basin Total 0.43 <br /> Element Flows To: <br /> Surface Interflow Groundwater <br /> MITIGATED LAND USE <br /> Name : Developed <br /> Bypass: No <br /> GroundWater: No <br /> Insight Engineering Co. -Stormwater Site Plan 09/10/18 <br /> -20- <br />