My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
>
Address Records
>
RUCKER AVE
>
3632
>
THE LANDING AT PORT GARDNER
>
3632 RUCKER AVE THE LANDING AT PORT GARDNER 2023-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 3:14:26 PM
Creation date
4/6/2023 3:10:05 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3632
Tenant Name
THE LANDING AT PORT GARDNER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
225
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Note 1-Insulation that is continuous except for fasteners may be entered here if the cross-sectional area of metal penetration through otherwise <br /> continuous insulation is less than 0.12%. <br /> Note 2-Alternate prescriptive continuous insulation R-values per Table C402.1.4,Footnote F may be used if the cross sectional area of metal <br /> penetrations exceeds 0.04%but is less than 0.12%.Calculations are required to use these alternate R-values. <br /> Note 3-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.Specify the <br /> table number or calculation page number. <br /> Note 4-Thermal spacer blocking and liner system are required for prescriptive R-Value compliance in metal building roof assemblies.Note thermal <br /> spacer thickness and R-value in roof assembly description. <br /> Note 5-Intermediate framing is required for prescriptive R-Value compliance in wood-framed wall assemblies. <br /> Note 6-Proposed CMU mass walls in non-Group R that meet Table C402.1.4 Footnote C requirements can enter the target prescriptive <br /> U-value of 0.104. <br /> Note 7-Mass transfer slab edges must be covered with an assembly having an overall U-factor of 0.2. <br /> Note 8-Refer to Table C402.1.3,Footnote E for prescriptive R-Value requirement for steel floor joist assemblies. <br /> Note 9 -Prescriptive slab-on-grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. <br /> Note 10-Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 11-Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 12-Refer to Equation C4-6 Projection Factor Calculation. <br /> Note 13-N=Oriented within 45 degrees of true north,SEW=All other orientations. <br /> Note 14-Fenestration assembly U-Factor and SHGC shall be the manufacturer's NFRC product rating,which includes the glazing and frame,or <br /> shall be the default value per Section C303.1.3. <br /> Note 15-List all above-grade Group R mass walls and steel frame walls in Group R Walls section.List commercial above grade walls and all other <br /> Group R above grade walls in Opaque Walls-Above Grade. <br /> Note 16-Refrigerated Coolers-All cooler roof,wall and door assemblies shall comply with the prescriptive R-values or U-factors per C410.Enter <br /> proposed information under the most similar assembly type.Slab edge insulation for slab-on-grade floors shall comply with C402.Floors <br /> that <br /> separate a cooler from a non-cooler space(unconditioned and conditioned)shall be insulated per C402. Vertical fenestration(not within <br /> cooler doors)shall comply with the prescriptive R-values or U-factors per C402.Enter only the opaque portion of refrigerated space doors. <br /> Windows within doors and reach-in display case doors shall comply with C410 prescriptive requirements. <br /> Note 17-Refrigerated Freezers-All freezer roof,wall and door assemblies shall comply with the prescriptive R-values or U-factors per C410.Enter <br /> proposed information under the most similar assembly type.Freezer floor insulation shall comply with C410.Insulation is required under the <br /> entire freezer floor.If the freezer floor assembly rests on top of a standard floor,the vertical edge of the freezer floor shall be entered as and <br /> comply with the requirements for a freezer wall.If freezer floor insulation is installed as integral to or applied underneath a slab-on-grade or <br /> exposed floor,this floor shall be thermally broken from the surrounding floor area with the same amount of insulation as required for a <br />
The URL can be used to link to this page
Your browser does not support the video tag.