2 1 3 14 15 <br />Mechanical Key Notes Symbols Legend General Notes - Demoltion Plan <br />E <br />Building Data Relocate Misc. diffusers to match new floor Ian. 1. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND DEBRIS AT ALL TIMES. 6. EXISTING SMOKE DETECTORS, FIRE ALARMS, STROBES AND OTHER SIMILAR DEVICES SHALL REMAIN <br />P EXISTING WALL TO REMAIN OPERATIONAL AT All TIMES. PROTECTION OF SUCH DEVICES DURING CONSTRUCTION (I.E. COVERING <br />See clouded area of Work below. 2. ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT DEVICES FROM DUST) AND/OR DISCONNECTING SUCH DEVICES SHALL BE PERFORMED IN <br />1. CONSTRUCTION TYPE: TYPE V-e 5. SITE ADDRESS: _ _ _ = EXISTING WALL TO BE DEMOLISHED REQUIREMENTS AND PROCEDURES. ACCORDANCE WITH LOCAL FIRE DEPARTMENT REGULATIONS. <br />2500 Hewitt Avenue <br />2. BUILDING AREAS: EVERETT, WA 98201 3. CONTRACTOR SHALL CAP ALL WATER SUPPLY AND WASTE WITHIN THE NEAREST WALL OR FLOOR 7, WHERE NOT SPECIFICALLY INDICATED ON THE DRAWINGS, THE OWNER SHALL HAVE THE RIGHT TO <br />TOTAL BUILDING AREA: 13,346 S.F. SURFACE. PROVIDE CLEAN-OUr FOR CAPPED WASTE LINES. RETAIN EQUIPMENT AND FURNISHINGS THAT ARE REMOVED AS PART OF THE WORK. CONTRACTOR <br />AREA OF WORK: 7,490 S.F. 6. TAX #00437869300900 EXISTING DOOR AND FRAME TO REMAIN SHALL COORDINATE WITH THE OWNER THE DISPOSITION OF ITEMS INCLUDING BUT NOT UMITED TO <br />4. ABANDONED ELECTRICAL AND LOW -VOLTAGE UNES SHALL BE REMOVED COMPLETELY. CASEWORK, FURNITURE, A/V EQUIPMENT, APPLIANCES, ETC EITHER FOR DISPOSAL OR STORAGE BY <br />3. OCCUPANCIES: 7. LEGAL DESCRIPTION: THE OWNER. <br />B- OFFICES SW 1/4 SEC20 T29N R5E 5. EXISTING SURFACES THAT ARE NOT INDICATED FOR REMOVAL THAT ARE DAMAGED DURING DEMOLITION <br />WORK SHALL BE REPAIRED TO MATCH PRE-CONSTRUCTION/DEMOLITION CONDITION AT NO COST TO 8. WHERE NOT SPECIFICALLY INDICATED ON THE DRAWINGS, THE OWNER SHALL HAVE THE RIGHT TO <br />4. SPRINKLED BUILDING 8. ZONING: THE OWNER. PROPOSED REPAIR WORK, METHOD OF REPAIR, EXTENT OF REPAIR AND FINISHED RETAIN BUILDING COMPONENTS THAT ARE REMOVED AS PART OF THE WORK. CONTRACTOR SHALL <br />Mu APPEARANCE OF THE REPAIR SHALL BE RENEWED BY THE ARCHITECT FOR APPROVAL. COORDINATE WITH THE OWNER THE DISPOSITION OF ITEMS INCLUDING BUT NOT LIMITED TO DOORS, <br />DOOR FRAMES, UGHT AND PLUMBING FIXTURES, ETC ETHER FOR DISPOSAL OR STORAGE BY THE <br />OWNER. <br />E <br />CONSULTANT: <br />F.DI�v <br />s ❑ I, <br />-- <br />HOW <br />D <br />Redistribute - - - - - - - - - - - - - - - - - - - - - - - - - -'- - -------------`------------------- - - - - -' <br />Diffusers to match L_____________________________ _ I 1 <br />new floor plan. <br />Typ of 8 <br />® oxremai isting Return Duct D.F. D. <br />El <br />PROJECT . • <br />`_--- <br />- - - -------------------- - -- Existing Supply duct <br />to remain <br />--------Tenant <br />-- <br />Improvement <br />0 <br />FOR <br />Lutheran Community <br />IO <br />11 3 <br />II I <br />Services <br />AT <br />I <br />Area of Work I <br />Redistribute I <br />Diffusers to match I <br />new floor plan <br />i l <br />Petersen Building <br />2500 Hewitt Avenue <br />Everett, WA 98201 <br />ill <br />HVAC <br />C <br />I I I ill I I I I I I <br />II <br />II <br />II <br />II <br />Area of Work I <br />Redistribute I <br />2 Diffusers to match I <br />new floor plan <br />C <br />• <br />I ill I I I I I I <br />illMARK <br />DATE DESCRIPTION <br />IlO J <br />FFF <br />O o <br />Redistribute -- - - ---- - - - - ------------------ - - - - ---------------- - - - - -------------------- - - - - -. <br />Diffusers to match ` - - - - - <br />new floor plan. Existing Supply duct <br />Typ of 8 � � � to remain <br />e <br />- • <br />Existing return duct <br />--------------------------------------- ----------------------------------------- <br />to remain <br />Williams Mechanical <br />3903 Smith Ave <br />1 <br />I I <br />Everett, WA 98201 <br />I I <br />7 5/8" 9•-8 3/8" 10'-0" 10'-0" 10'-0" 10' 0 1'-0 1/2" 5'-11 1/2" 20'-0" 10'-0" 10'-0" 9'-4" <br />M22 1 2-003 <br />DRAWING TITLE <br />HVAC <br />A <br />A B 13.1 C D E F G G.5 H J K L L <br />PLAN/ EXISTING <br />A <br />CONDITIONS <br />MECHANICAL PLAN <br />1/4„=,' NOTE: <br />0 2' 4' 8' <br />Area of work in the two clouded areas Scale, ,,4-,9 <br />DRAWING NUMBER <br />M-1 <br />NORTH <br />12 1 22 <br />1 2 3 4 5 6 <br />