Laserfiche WebLink
• • <br /> /dimple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> SHORE AVENUE LOT 2 HAYWARD HOMES LLC <br /> Heating System Type: 4,Al Other Systems ,%Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions _ Design Temperature Difference(AT) 47 <br /> Ev`. _.II' sT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 3,026 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 9.4 28,444 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> II n Sri V 0.300 463 138.90 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 0 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions 11.49 0.026 1,871 48.65 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions 0 <br /> No V,tl,it,�r1(.e ,,,1, ,;vvi thy.rr,,I,t v <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions u t tY u i�I 0.056 2,478 138.77 <br /> Floors U-Factor X Area UA <br /> Instructions --- 1,875 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 0.028 0 <br /> N -,,,Belnw Grade Walls in this pro, t V -- <br /> Slab Below Grade(see Figure 1) F-Factor X Len•th UA <br /> Instructions 0.303 0 <br /> N r,',I,al,B,1,,t,,,,,,d,,,,tlt,e.pinlnrt V <br /> Slab on Grade(see Figure 1) F-Factor X Len•th UA <br /> Instructions 0 <br /> No Sl,,l,or,Gi,,,it,,,,II,,.I'irr,t V <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> ,,,,a,,,,,,,.1 v.,t, V 1.00 <br /> Sum of UA 326.31 <br /> Envelope Heat Load 15,337 Btu/Hour <br /> Figure 1. Sum ofUAXAT <br /> Air Leakage Heat Load 14,438 Btu/Hour <br /> VolumeX 0.6XATX.018 <br /> Above Grade Building Design Heat Load 29,775 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 29,775 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 41,685 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (13L-D.3.--- (07/01/13) <br />