Laserfiche WebLink
'versions can cause greater impacts than would otherwise occur by discharging runoff at the nat- <br /> ura 'cation. <br /> Where conveyance system exists at the adjacent downgradient property line and the discharge <br /> was previo► ly unconcentrated flow or significantly lower concentrated flow,then measures must be <br /> taken to prey-•t downgradient impacts. Drainage easements from downstream property owners <br /> may be needed - id should be obtained prior to approval of engineering plans. <br /> The following dischar. - requirement is recommended: <br /> Where no conveyance sy -m exists at the abutting downstream property line and the natural(exist- <br /> ing)discharge is unconcentr- ed,any runoff concentrated by the proposed project must be dis- <br /> charged as follows: <br /> a. If the 100-year peak discharg- as estimated using an approved continuous runoff model <br /> using 15-minute time steps, is le than or equal to 0.3 cfs under existing conditions and will <br /> remain less than or equal to 0.3 cfs ► der developed conditions,then the concentrated runoff <br /> may be discharged onto outlet protects with riprap,such as those described in V-1.4.3 Out- <br /> fall Systems,or to any other system that -rues to disperse flows. <br /> b. If the 100-year peak discharge,as estimated .ing an approved continuous runoff model <br /> using 15-minute time steps, is less than or equal • 0.75 cfs under existing conditions and will <br /> remain less than or equal to 0.75 cfs under develop • conditions,then the concentrated runoff <br /> may be discharged through a dispersal trench,such a hose described in V-1.4.3 Outfall Sys- <br /> tems,or other dispersal system, provided the applicant . • demonstrate that there will be no <br /> significant adverse impact to downhill properties or drainag- . stems. <br /> c. If the 100-year peak discharge,as estimated using an approved .•ntinuous runoff model <br /> using 15-minute time steps,is greater than 0.75 cfs for either existino or developed conditions, <br /> or if a significant adverse impact to downgradient properties or draina• - systems is likely,then <br /> a conveyance system must be provided to convey the concentrated runo -cross the down- <br /> stream properties to an acceptable discharge point(i.e.,an enclosed draina• - system or open <br /> drainage feature where concentrated runoff can be discharged without signifi - t adverse <br /> impact). <br /> Stormwater control or treatment structures should not be located within the expected 25-yea ater <br /> level elevations for salmonid-bearing waters.Such areas may provide off-channel habitat for ju -n- <br /> ile salmonids and salmonid fry. Designs for outfall systems to protect against adverse impacts fro <br /> concentrated runoff are included in V-1.4.3 Outfall Systems. <br /> 1-3.4.5 MR5: On-Site Stormwater Management <br /> Projects shall employ Stormwater Management BMPs in accordance with the following <br /> thresholds,standards,and lists to infiltrate,disperse,and retain stormwater runoff on site to the <br /> extent feasible without causing flooding or erosion impacts. <br /> 2019 Stormwater Management Manual for Western Washington <br /> Volume I-Chapter 3-Page 115 <br />