Laserfiche WebLink
N <br /> qLECTRIC <br /> SEN <br /> US PROBATION COURT OFFICE <br /> 00 <br /> INC. wY <br /> z <br /> 1000 SE EVERETT MALL WAY,SUITE 350 2 i <br /> EVERETT,WA 98208 t <br /> N <br /> PROJECT MANGER o <br /> OLSEN ELECTRICA 04 <br /> CONTACT:ERIC OLSEN W U° I_ <br /> PHONE:(253)872-1905 symbols Abbreviations " N <br /> General Power CIJ <br /> Sym mboSymbols <br /> mbols o <br /> N <br /> Revision Identifier Duplex Receptacle A/C Air Conditioning(er) H Height PNL Panel d M <br /> ILL <br /> GFCI-Ground Fault Circuit Interrupter A(Amp) Ampere HID High Intensity Discharge POC Point of Connection <br /> VICINITY MAP m TDupl Timer AC Above Counter,Alternating Current HOA Hand Off Automatic PSE Puget Sound <br /> Revision Identifier 9 9 Energy <br /> Revision Fla l (2) Duplex Receptacle ADJ ADJT Adjacent HP Horizontal Horsepower <br /> PWR Power <br /> 9 GFCI-Ground Fault Circuit Interrupter 1 P <br /> AFF Above Finished Floor HPS High Pressure Sodium Q Quanity <br /> Mach Equip Designated:Top Half Indicates Type of Equip; �( Dedicated Duplex Receptacle AHJ Local Authority Having Jurisdiction HR Hour <br /> Bottom Half Indicates Equip Number. AIC Amperes Interrupting Capacity HT Height R Raceway,Resistance <br /> 1F r1 �' ��� • - Jf i _ <br /> C4 Duplex Receptacle(Above Counter) ALT Alternative HW Hot Water RAD(R)Radius <br /> 0 Lighting Fixture Type ANN Annunciator HWC Hot Water Circulation RECPT Receptacle <br /> Receptacle(208V.1 ,AMP as Indicated) ARCH Architect;Architectural HWR Hot Water Return REF Refrigerator <br /> � X <br /> _ i t Circuit ASCC Available Short Circuit Current HWS Hot Water Supply RLA Running Load Amps <br /> ! ~M� <br /> Symbols +44� Distance From Finished Floor To Center Of Device. AUTO Automatic HZ Hertz RPM Revolutions Per Minute <br /> AUX Auxiliary <br /> `• ® Equipment Connection ry 11 Tom, <br /> Circuit Concealed In Ceiling or Wall,Power AWG American Wire Guage IC Intercom S South <br /> ® Hand Dryer Connection IES Illuminatin Engineers Society Sc Security <br /> xv� _ 4* r Circuit Concealed In Floor or Underground 9 9 ty y r T <br /> S - i ' -P _ I 0 Transformer For IR Faucet Power(By E.C.) BKBD Backboard IG Isolated Ground SCD Smoke Control Damper !W� <br /> Jrab ;. © ' s�;r �� BKR Breaker IMC Intermediate Metal Conduit SCL Seattle City Light <br /> Q" y Circuit Home Run(Panel-Circuit(Building)) <br /> ra �' - L1-3(8 ® DDC Connection-Provide(2)120V 20 Amp BLDG Building IN Inch SO Smoke Detector <br /> ,t DDC Circuits <br /> Large Mark Indicates Neutral,Short Mark Indicates Phase SECT Section <br /> *a ! '" J'r t -y� '. ° E_T Or Switchleg,#12 AWG UON C Conduit JB Junction Box SF Supply Fan <br /> A <br /> CP Capacity SHT Sheet <br /> $, Sealtite Flexible Conduit a 208Y/120V Panel Board !rte' <br /> CB Circuit Breaker KV Kilovolt SPEC Specification L � <br /> ___O Circuit Turning Up CF Cubic Feet KVA Kilovolt Amperes SPL Special ch <br /> r '!• - ;1 ! CFM Cubic Feet Per Minute KVAR Kilovolt Amperes Reactive SQ Square fr', W <br /> 9 D Circuit Turning Down Combination Magnetic Motor Starter With Disconnect <br /> j. ftr7t p., n .1 -j he< 3 CKT Circuit KW Kilowatt STOR Storage <br /> ww !d4444j !• 'AF 7�" !�' Switch And Fusing As Required <br /> �c Circuit Stub Up/Out CLG Ceiling KWH Kilowatt Hour SW Switch <br /> CLR Clear SWBD Switchboard <br /> Circuit Continuation o0 <br /> Disconnect COL Column LBS Pounds SYM Symmetrical �r O <br /> t Feeder,Circuit or Home Run Within 2 Hour Assembly i COM Common LCC Lighting Control Cabinet SYS System Q C <br /> = Grounding COMM Communication LRA Locked Rotor Amps O 0C <br /> y ! ® Junction Box l <br /> _ _ _ CPS Cycles Per Second LT Light T Thermostat v a <br /> Proposed Heat Trace Routing.Verify Heat Trace Connection O Meter CT Current Transformer LTG Lighting TB Terminal Box a 3 <br /> V I Op Locations And Requirements Prior To Rough-In. CTL Control LV Low Volt TC Time Clock Q <br /> (D Exhaust CU Copper TEL Telephone <br /> Lighting Fan CUH Cabinet Unit Heater MAG Magnetic TV Telephone <br /> Symbols Panel MAN Manual TVSS Transient Voltage Surge [� <br /> Board DC Direct Current MAT Material Suppression O W W <br /> DRAWING INDEX Shaded Circle Or Comer Indicates Pathway Lighting Fixture. DG Dedicated Ground MAX Maximum TYP Typical W <br /> Applies To All Fixture Types. DISC SW Disconnect Switch MCA Minimum Circuit Amps ~� W <br /> UBC Uniform Building Code ,7 <br /> DISC Disconnect MCB Main Circuit Breakers UFC Uniform Fire Code W <br /> Fluorescent 2x4 Lighting Fixture,Recessed Or Lay In. DN Down MCM Thousand Circular Mills UG Underground W <br /> !� <br /> 7C DWG Drawing MD Motorized Damper UGE Underground Electrical <br /> E1 CO V L'R PAGE MECH Mechanical UGT Underground Telephone O <br /> 0 Fluorescent 1x4 Lighting Fixture,Recessed Or Lay In. O <br /> E Exist,East MMezzanine UH Unit Heater O <br /> E2 OFFICE POWER PLAN Communication EC Electrical Contactor MGG Motor Generator UL Underwriters Laboratories .--� <br /> Strip Fluorescent Fixture(Surface Of Chain Mounted) EDH Electric Duct Heater MH Metal Halide UV Unit Ventilator <br /> E3 OFFICE LIGHTING PLAN Symbols EF Exhaust Fan MIN Minimum O <br /> O Ceiling Mounted Lighting Fixture.Surface,Recessed,Or Combination Tele/Data EGC Equipment Ground Conductor MISC Miscellaneous V Volt <br /> E4 OFFICE SECURITY PLA�r Pendant.See Lighting Fixture Schedule. Outlet EL Elevation MLO Main Lug Only VAV Variable Air Volume <br /> E5 PANEL SCHEDULES K� Wall Mounted Fixture. See Fixture Schedule. Telephone Outlet ELEC Electric(al) MOCP Maximum Overcurrent Protection VEL Velocity <br /> ELEV Elevator MS Magnetic Starter VFD Variable Frequency Drive <br /> C Self Contained Emergency Lighting Fixture. Q Data Cable Outlet EM Emergency MTD Mounted VM Voltmeter ^ <br /> EMD Estimated Maximum Demand MTG Mounting VOL Volume �••1•� <br /> I@ Exit Sign,Surface Wall Mounted,Universal Mounted. OEMT Electrical Metallic Tubing MTR Motor <br /> CR Card Reader V 1 <br /> Directional Arrow(s)As Indicated. ENCL Enclosure MV Mercury Vapor W Watt,West <br /> e Exit Sign,Ceiling Mounted,Universal Mounted. DH Magnetic Door Holder ENTR Entrance W/ With <br /> Directional Arrow(s)As Indicated. EP Explosion Proof N North;Neutral W/O Without <br /> DC Door Contact EPO Emergency Power Off N/A Not Applicable WH Water Heater <br /> Light Fixture Circuit Number Or Switch Leg. EQUIP**Equipment NC Normally Closed WHM Watthour Meter <br /> Light Fixture Type. See Light Fixture Schedule. Camera EWC Electrical Water Cooler NEC National Electric Code WP Weatherproof <br /> x <br /> Light Fixture EWH Electrical Water Heater NEMA National Electric Manufactures Association <br /> XK <br /> IC Intercom EXH Exhaust NESC National Electric Safety Code X Reactive <br /> MA­Dimmer EXT Exterior NEUT Neutral XFMR Transformer <br /> Wireless Antenna EXIST Existing NFPA National Fire Protection Agency XMTR Transmitter <br /> NIC Not In Contract Revisions: <br /> Switch Single Pole;Smaller Letter Indicates Fixture With Z Impedance <br /> Same Letter In Room Shall Be Connected To Switch. F Fahrenheit NO Normally Open g, And Rev Date Description <br /> FA Fire Alarm NTS Not to Scale IE: That Is 1 3/31/21 SHOP <br /> Switch,3 Way FAA Fire Alarm Annunciator # Number 2 4/23/21 SHOP <br /> GENERAL NOTES Switch,4 Way FAP Fire Alarm Panel OC On Center 3 6/16121 SHOP <br /> FC Foot Candle OFCI Owner Furnished Contractor Installed <br /> Switch Motor Rated Toggle FCU Fan Coil Unit OFF Office <br /> FD Fire Damper OFOI Owner Furnished Owner Installed <br /> a Lighting Control Panel FDR Feeder OHP Overhead Power <br /> FureOverhead <br /> AS-BUILTS WILL BE PROVIDED AT COMPLETION OF JOB ® Photo Cell NOTE: FILA XT FII Load Amps OLT OverloadTelephone <br /> Wall Mtd.Fluorescent Fixture Not all of the above information is FLEX Flexible <br /> incorporated in the drawings, FOIC Furnished By Owner,Installed By Contractor P Primary <br /> C] Wall Mtd.Incandescent Fixture Lighting and Power spec sheets FS Follow Switch PA Public Address <br /> have there own legend. FSD Fire/Smoke Damper PAR Parallel <br /> Surface Mid.Fluorescent Fixture FVNR Full Voltage Non-Reversing PB Pull Box <br /> FVR Full Voltage Reversing PE Photo Electric <br /> Pendant PF Power Factor <br /> GEN Generator PH Phase <br /> Undercabinet Fluorescent Fixture GFCI Ground Fault Circuit Interrupter PIV Post Indicator Valve <br /> GFR Ground Fault Relay Drawn By:AG <br /> —�— Track Lighting Sha,— <br /> El <br />