My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8907 5TH AVE W 2023-04-11
>
Address Records
>
5TH AVE W
>
8907
>
8907 5TH AVE W 2023-04-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2023 8:44:49 AM
Creation date
4/7/2023 9:22:48 AM
Metadata
Fields
Template:
Address Document
Street Name
5TH AVE W
Street Number
8907
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at <br /> energycode@energy.wsu.edu or(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 2350 Vlad Monich <br /> 425-508-7521 <br /> - 0 All Other Systems ®Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions" <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 49 <br /> EverettPaine AFB vAT=Indoor(70 degrees)-Outdoor Design Temp <br /> Ares ^t <br /> Conditioned Floor Area <br /> "''' °r'' Conditioned Floor Area(sq ft) 2,350 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 19,975 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> •U-0.28 v 0.280 331 92.68 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions x 4y I 0.026 1,436 37.34 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Select R-Value I No selection --- <br /> Above Grade Walls(see Figure 1) ,1 U-Factor X Area UA <br /> Instructions R 21 Intermediate 0.056 2,255 126.28 <br /> .c <br /> Floors U-Factor X Area UA <br /> Instructions ho R-30 V 0.029 1,436 41.64 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions III Select R-value J No selection --- <br /> Slab Below Grade(see Figure 1) F-Factor X Len th UA <br /> Instructions No selection <br /> Select conditioning v --- <br /> Slab on Grade(see Figure 1) F-Factor X Len UA <br /> Instructions V Select R-Value No selection --- <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Unconditioned Space v <br /> 1.10 <br /> Sum of UA 297.94 <br /> Envelope Heat Load 14,599 Btu/Hour <br /> Figure 1. Sum of UA x AT <br /> Air Leakage Heat Load 10,571 Btu/Hour <br /> Volume x 0.6 x AT x 0.018 <br /> Above Grade <br /> Building Design Heat Load 25,170 Btu/Hour <br /> Air leakage+envelope heat loss <br /> Building and Duct Heat Load 27,687 Btu/Hour <br /> Ducts in unconditioned space:sum of building heat loss x 1.10 <br /> Ducts in conditioned space:sum of building heat loss x 1 <br /> Maximum Heat Equipment Output 34,609 Btu/Hour <br /> Building and duct heat loss x 1.40 for forced air furnace <br /> Building and duct heat loss x 1.25 for heat pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.