My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10725 19TH AVE SE Geotech Report 2023-04-07
>
Address Records
>
19TH AVE SE
>
10725
>
Geotech Report
>
10725 19TH AVE SE Geotech Report 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 2:03:38 PM
Creation date
4/7/2023 1:55:54 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10725
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Evaluation NGA File No. 1014317 <br /> Zerzura Townhome Development November 9,2017 <br /> Everett,Washington Page 8 <br /> Lateral loads may be resisted by friction on the base of the footing and passive resistance against the <br /> subsurface portions of the foundation. A coefficient of friction of 0.35 may be used to calculate the base <br /> friction and should be applied to the vertical dead load only. Passive resistance may be calculated as a <br /> triangular equivalent fluid pressure distribution. An equivalent fluid density of 200 pounds per cubic foot <br /> (pcf) should be used for passive resistance design for a level ground surface adjacent to the footing. This <br /> level surface should extend a distance equal to at least three times the footing depth. These recommended <br /> values incorporate safety factors of 1.5 and 2.0 applied to the estimated ultimate values for frictional and <br /> passive resistance, respectively. To achieve this value of passive resistance, the foundations should be <br /> poured "neat" against the native medium dense soils or compacted fill should be used as backfill against <br /> the front of the footing. We recommend that the upper one foot of soil be neglected when calculating the <br /> passive resistance. <br /> Retaining Walls <br /> The lateral pressure acting on subsurface retaining walls is dependent on the nature and density of the soil <br /> behind the wall,the amount of lateral wall movement which can occur as backfill is placed,wall drainage <br /> conditions, and the inclination of the backfill. For walls that are free to yield at the top at least one <br /> thousandth of the height of the wall (active condition), soil pressures will be less than if movement is <br /> limited by such factors as wall stiffness or bracing (at-rest condition). We recommend that walls <br /> supporting horizontal backfill and not subjected to hydrostatic forces, be designed using a triangular earth <br /> pressure distribution equivalent to that exerted by a fluid with a density of 40 pcf for yielding (active <br /> condition)walls,and 60 pcf for non-yielding(at-rest condition)walls. <br /> These recommended lateral earth pressures are for a drained granular backfill and are based on the <br /> assumption of a horizontal ground surface behind the wall for a distance of at least the subsurface height <br /> of the wall, and do not account for surcharge loads. Additional lateral earth pressures should be <br /> considered for surcharge loads acting adjacent to subsurface walls and within a distance equal to the <br /> subsurface height of the wall. This would include the effects of surcharges such as traffic loads,floor slab <br /> loads, slopes, or other surface loads. We could consult with the structural engineer regarding additional <br /> loads on retaining walls during final design, if needed. <br /> The lateral pressures on walls may be resisted by friction between the foundation and subgrade soil, and <br /> by passive resistance acting on the below-grade portion of the foundation. Recommendations for <br /> frictional and passive resistance to lateral loads are presented in the Foundations subsection of this <br /> report. <br /> NELSON GEOTECHNICAL ASSOCIATES,INC. <br />