My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1520 80TH ST SW HELION 2023-04-28
>
Address Records
>
80TH ST SW
>
1520
>
HELION
>
1520 80TH ST SW HELION 2023-04-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2023 11:17:42 AM
Creation date
4/7/2023 2:12:21 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1520
Tenant Name
HELION
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Instrument Calibration & Symbol Abbreviation Report <br /> UMC <br /> INTERNATIONAL TEBTIND,ADUU.K AND BALANCING BUREAU <br /> CERTIFICATION BOARD THE RROFESSIONAL'S CNOICE- <br /> Instrument Instrument Instrument Model Serial# Application Dates of use Calibration <br /> Manufacturer No. date <br /> Pressure/Velocity Module Evergreen Tele. S-PVF-1 1800435 Pressure 5/21 2/17/21 <br /> Capture Hood Evergreen Tele. CH-15D 1800223 CFM 5/21 2/3/21 <br /> Temperature Evergreen Tele. RM-T-1 1800133 Temperature 5/21 2/17/21 <br /> Humidity Sensor Evergreen Tele. S-H-3-5'I 1800273 Humidity 5/21 2/17/21 <br /> Temperature Evergreen Tele. PR-T-2 1800123 Temperature 5/21 2/17/21 <br /> Temperature Evergreen Tele. PR-T-4-6 1800208 Temperature 5/21 2/17/21 <br /> Water Pressure Module Evergreen Tele. S-DP-250 A-1800172 Hydronics 5/21 2/17/21 <br /> Rotating Vane Alnor RVA501 501832002 Velocity N/A 8/8/18 <br /> Tachometer Shimpo DT-250LR G050486 RPM N/A 8/12/18 <br /> SYMBOLS&ABBREVIATIONS <br /> ADJ Adjustable Fan Speed LD Linear Diffuser <br /> CD Ceiling Diffuser LD x Linear Diffuser where x is <br /> CFM Cubic Feet per Minute number of slots <br /> D/A VAV Inlet Dimension in Inches N/A Not Applicable <br /> D.S.P Discharge Static Pressure NI Not Installed <br /> EG Exhaust Grille NR Not Required <br /> E.S.P. External Static Pressure NPSH Net Positive Suction Head <br /> F/C VAV Calibration Factor RG Return Grille <br /> FLA Motor Full Load Amps RPM Revolutions per Minute <br /> GPM Gallons per Minute SF Motor Service Factor <br /> HP Horsepower S.P. Static Pressure <br /> Hz Hertz SWG Side Wall Grille <br /> in.Hg. Inches Mercury 5/5/2021 Total Static Pressure <br /> in.w.g. Inches Water Gauge VAR Variable Fan Speed <br /> HRU Heat Recovery Unit - Not affected/Unreadable <br /> ERV Energy Recovery Unit CU Condenser Unit <br /> AHU Air Handler Unit FCU Fan Coil Unit <br /> VAV Variable Air Volume <br /> REMARKS <br /> Page 2 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.