My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10721 19TH AVE SE 2023-04-07
>
Address Records
>
19TH AVE SE
>
10721
>
10721 19TH AVE SE 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 2:36:50 PM
Creation date
4/7/2023 2:34:25 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10721
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 - • • - : - • - 11 - 1 1111 - , ng2 ENV-REQ <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Definitions: <br /> Ls=Liner system--A continuous membrane installed below the purlins and uninterrupted by framing members. Uncompressed,unlaced <br /> insulation rests on top of the membrane between the purlins.Refer to Section A102.2.5.4. <br /> c.i.=Continuous insulation--Insulation that is continuous across all structural members without thermal bridges other than service <br /> openings and penetrations by metal fasteners with a x-sectional area of less than 0.04%of the opaque surface area of the assembly. <br /> Components with more than 0.04%metal penetrations may be eligible to follow the alternate CI values below. <br /> int=Intermediate framing--Includes insulated headers,corners and interior partition wall to exterior wall intersections.Refer to Section <br /> A 103.2 for framing definitions. <br /> Footnote Summary: <br /> Each table in the 2015 WSEC has footnotes applicable to specific information provided in the table.This footnote summary provides only <br /> abbreviated details from these footnotes. Refer to 2015 WSEC for complete footnote information. <br /> Note 1 -Assembly descriptions can be found in Chapter 2 and Appendix A. <br /> Note 2-Use of assembly U-factors,C-factors and F-factors from Appendix A and Chapter 3 are required unless otherwise allowed <br /> by the provisions of this Code. <br /> Note 3-For metal building roofs where using R-value compliance method,a thermal spacer block with minimum thickness of 1/2-inch <br /> and minimum R-value of R-3.5 is required.Otherwise use the U-factor compliance method. <br /> Note 4-Where heated slabs are below-grade,they shall comply with the F-factor requirements for slab-on-grade heated slabs. <br /> Note 5-Heated slab F-factors shall be determined specifically for heated slabs.Unheated slab F-factors shall not be used. <br /> Note 6-CMU walls in all occupancies other than Group R may be eligible for reduced insulation if all provisions stated in applicable <br /> footnote are met.Refer to Footnote D in Table C402.1.4 or Footnote C in Table C402.1.3 for eligibility requirements. <br /> Note 7-Components with continuous insulation but with metal penetrations/connections may be eligible for alternate continuous <br /> insulation R-values if all provisions in applicable footnote are met. Refer to alternate prescriptive R-values in table below <br /> and Footnote G in Table C402.1.3 for eligibility requirements. <br /> Alternate continuous insulation nominal R-values <br /> This alternate nominal R-value compliance option is allowed for projects complying with all of the following: <br /> .The ratio of the cross-sectional area,as measured in the plane of the surface,of metal penetrations of otherwise continuous <br /> insulation to the opaque surface area of the assembly is greater than 0.0004(0.04%),but less than 0.0012(0.12%). <br /> 2.The metal penetrations of otherwise continuous insulation are isolated or discontinuous(e.g.,brick ties or other <br /> discontinuous metal attachments,offset brackets supporting shelf angles that allow insulation to go between the shelf <br /> angle and the primary portions of the wall structure).No continuous metal elements(e.g.,metal studs,z-girts,z-channels, <br /> shelf angles)penetrate the otherwise continuous portion of the insulation. <br /> 3.Building permit drawings shall contain details showing the locations and dimensions of all the metal penetrations(e.g., <br /> brick ties or other discontinuous metal attachments,offset brackets,etc.)of otherwise continuous insulation.In addition, <br /> calculations shall be provided showing the ratio of the cross-sectional area of metal penetrations of otherwise continuous <br /> Assemblies with Alternate option for assemblies with Alternate option fir assembles with <br /> continuous metal penetrations,greater than metal penetrations,greater than or <br /> insulation(see 0.04%%but less than 0.•8% equal to O.N%but less than 0.124 <br /> detiettwn) <br /> R-9.5ci R-11.9ci R-13ci <br /> R 11.4ci R-143d R 15.7ci <br /> R-13.3ci R-16.6ci R-183ci <br /> '—---R-15.2d R-19.Oci R-21d <br /> -— R-3Oci R-38ci R-42ci <br /> R-38ci R-48ci R-53ci <br /> R-13+R-7.5ci R-13+R-9.4d R-13+R-10.3c1 <br /> R-13+R-10ci R-13+R-12.5a R-13+R-13.8ci <br /> R-13+R-123d R-13+R-15.6a R-13+R-17.2d <br /> R-13+R-13ci R-13+R-16.3ci R-13+R-17.9d <br /> R-19+R-8.5ci R-19+R-10.6d R-19+R-11.7a <br /> R-19+R-14ci R-19+R-17.5a R-19+R-19.2ci <br /> R-19+R-16ci R 19+R-20ci R-19+R-22d <br /> R-20+R 3.8d R-20+R-4.2d R-20+R-53ci <br /> R-21+R-5ci R 21+R-6.3d R 21+R-6.9d <br /> End of Envelope Requirements Summary <br />
The URL can be used to link to this page
Your browser does not support the video tag.