My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10721 19TH AVE SE 2023-04-07
>
Address Records
>
19TH AVE SE
>
10721
>
10721 19TH AVE SE 2023-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 2:36:50 PM
Creation date
4/7/2023 2:34:25 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10721
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. Vertical Fenestration Target Area Adjustment Calculations <br /> Project Title: Zezura Townhomes-North Building Date 08/09/2018 <br /> _ If vertical fenestration area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+ DR <br /> AG=Above-grade <br /> Proposed Areas Vertical Fenestration Net Above Grade Wall Opaque Door <br /> Project Areas-> VF= 588.0 NW= 4884.0 DR= 223.0 <br /> Existing Non-project Areas-> VF= NW= <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert.Fen.Area <br /> 5695.0 X 30.0% - 100 = 1708.5 <br /> Total Vertical Delta Vertical Excess Vertical <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 588.0 - 1708.5 = -1120.5 II greater = <br /> � -112 0.5 / Multiplier applied to all <br /> Proposed Vertical <br /> Project Vertical Excess Vertical � Target Vertical Total Vertical Pro p <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> 588.0 - = 588.0 588.0 = 1.00 calculate Target Vertical <br /> Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 4884.0 + = 4884.0 - 4884.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> Tar et Areas - UA calculate Target Above- <br /> Target Grade Wall Area <br /> Commercial <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame 588.0 X 1.00 = 588.0 <br /> Metal frame,fixed X = <br /> Metal frame,operable X = <br /> Metal frame,entrance door X <br /> Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame X = target areas on ENV-UA <br /> Metal Building X = <br /> Wood/Other frame 4884.0 X 1.00 = 4884.0 <br /> Mass X = <br /> Mass Transfer Deck X = <br /> Group R Mass X = <br /> Sum of target above-grade <br /> Sum of Proposed 5472.0 Sum of Target 5472.0 wall and vertical <br /> fenestration areas are <br /> Target Areas - SHGC x A calculated to equal the <br /> sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 233.0 X 1.00 = 233.0 <br /> 0.2<_PF<0.5 X = <br /> PF>-0.5 X = SHGC target areas in <br /> shaded boxes are applied <br /> North Vertical Fenestration to target areas on ENV- <br /> PF<0.2 355.0 X 1.00 = 355.0 SHGC <br /> 0.25PF<0.5 X = <br /> PF>_0.5 X = - <br />
The URL can be used to link to this page
Your browser does not support the video tag.