• <br /> SHGC Calculation ENV-SHGC. <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Zezura Townhomes Date 08/09/2018 <br /> Target Insulation Allowance: For Building Department Use <br /> Fully Conditioned Space-Commercial,Group R,Mixed Use <br /> Fenestration Area as%gross above-grade wall area 9.5% Max.Target: 30.0% <br /> Skylight Area as%gross roof area 0.0% Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included in this worksheet. User Note <br /> Enter target SHGC values for this fenestration under proposed SHGC,so it is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x F SHGC x Area(A)= SHGC x A <br /> 0.35 <br /> SHGC 0.35 <br /> Skylight Totals <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A),SHGC x A Category SHGC x Area(A)= SHGC x A <br /> Vinyl Manufacturer A3.1 0.30 233 70 PF<0.2 0.40 233 93.2 <br /> 0.2<_PF<0.5 0.48 <br /> II <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are <br /> applied to the proposed design, Target <br /> SHGC will sum fenestration area by PF <br /> category. <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals 233.0 69.9 233.0 93.2 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A) SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch.ID Provide SHGC source and fenestration schedule ID Category <br /> Vinyl Manufacturer A3.1 I 0.30 355 107 PF<0.2 j 0.53 355 188.2 <br /> 0.2sPF<0.51 0.58 <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design, Target SHGC will <br /> sum fenestration area by PF category. <br /> � I <br /> North Window Totals 355.0 106.5 355.0 188.2 <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 588.0 176.4 588.0 281.4 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br /> C'::9r! <br />