head.end wall. Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub.The <br /> bottom end of the bar shall start between 36 inches and 42 inches above floor grade. <br /> EXCEPTION: The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the <br /> requirements of R330.8 at the control end and head end entry points. <br /> R330.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head end,and the back wall within the <br /> bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars <br /> shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. <br /> R330.8.5 Grab bars at shower stalls.Where shower stalls are provided to meet the requirements for bathing facilities,grab bars <br /> shall meet the requirements of R330.8. <br /> EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab <br /> bars at the seat end wall. A vertical floor to ceiling grab bar shall be installed within 4 inches of <br /> the exterior of the shower aligned with the nose of the built-in seat. <br /> R330.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and <br /> head end wall.Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower <br /> stall.The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. <br /> R330.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 <br /> inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls. Horizontal <br /> grab bars shall not interfere with shower control valves. <br /> R330.9 Ramps.All interior and exterior ramps,when provided, shall be constructed in accordance with Section R311.8 with a <br /> maximum slope of 1 vertical to 12 horizontal.The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be <br /> installed in accordance with R330.9.1. <br /> R330.9.1 Handrails for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal <br /> and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311.8.3.3. <br /> R330.10 Stair treads and risers. Stair treads and risers shall be constructed in accordance with R311.7.5. Handrails shall be <br /> installed in accordance with R330.10.1. <br /> R330.10.1 Handrails for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser <br /> to multiple risers. Handrails shall be installed in accordance with R311.7.8.1 through R311.7.8.4 <br /> R330.11 Shower stalls.Where provided to meet the requirements for bathing facilities, the minimum size of shower stalls for an <br /> adult family home shall be 30 inches deep by 48 inches long. <br /> RAMP MINIMUM REQUIREMENTS IF APPLICABLE: <br /> Handrail both sides <br /> -- Less than 4" 34"-38" <br /> Guard <br /> 36"min <br /> , �� 3'x 3'min <br /> -- <br /> _ landing <br /> 3'x3'min <br /> landing <br /> 3' - One unit vertical in twelve units horizontal 3' <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br />
The URL can be used to link to this page
Your browser does not support the video tag.