My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9017 4TH PL SE 2023-04-28
>
Address Records
>
4TH PL SE
>
9017
>
9017 4TH PL SE 2023-04-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2023 10:36:47 AM
Creation date
4/21/2023 8:53:05 AM
Metadata
Fields
Template:
Address Document
Street Name
4TH PL SE
Street Number
9017
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: M2301-086 Description:SFR Replace furnace and add HP <br /> Applied: 1/25/2023 Approved: 2/1/2023 Site Address: 9017 4TH PL SE <br /> Issued:2/2/2023 Finaled:4/21/2023 City,State Zip Code: EVERETT,WA 98208 <br /> Status: FINALED Applicant: NORDSTROM HEATING&AIR INC <br /> Parent Permit: Owner:WATSON KATHRYN A <br /> Parent Project: Contractor: NORDSTROM HEATING&AIR INC <br /> Details: <br /> Air Handler and HP <br /> SCHEDULED DATE COMPLETED DATE7MECHT06-FINAL <br /> PE INSPECTOR RESULT REMARKS <br /> 2/24/2023 2/24/2023 JEFF M RHODE CORRECTION see notes <br /> REQUIRED <br /> Notes: <br /> 2/17/2023 11:48 AM NORDSTROM HEATING&AIR INC <br /> Contact Name:Kathryn Watson <br /> Site Address:9017 4TH PL SE <br /> Phone:4255127591 <br /> e-Mail:office@nordstromheating.com <br /> -no emergency drain off of condensate <br /> 307.2.3 Auxiliary and Secondary Drain Systems <br /> In addition to the requirements of Section 307.2.1,where damage to any building components could occur as a result of overflow from the equipment <br /> primary condensate removal system,one of the following auxiliary protection methods shall be provided for each cooling coil or fuel-fired appliance <br /> that produces condensate: <br /> An auxiliary drain pan with a separate drain shall be provided under the coils on which condensation will occur.The auxiliary pan drain shall discharge <br /> to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain.The pan shall have a minimum depth of 11/2 <br /> inches(38 mm),shall be not less than 3 inches(76 mm)larger than the unit,or the coil dimensions in width and length and shall be constructed of <br /> corrosion-resistant material.Galvanized sheet steel pans shall have a minimum thickness of not less than 0.0236 inch(0.6010 mm)(No.24 gage). <br /> Nonmetallic pans shall have a minimum thickness of not less than 0.0625 inch(1.6 mm). <br /> A separate overflow drain line shall be connected to the drain pan provided with the equipment.Such overflow drain shall discharge to a conspicuous <br /> point of disposal to alert occupants in the event of a stoppage of the primary drain.The overflow drain line shall connect to the drain pan at a higher <br /> level than the primary drain connection. <br /> An auxiliary drain pan without a separate drain line shall be provided under the coils on which condensate will occur.Such pan shall be equipped with a <br /> water-level detection device conforming to UL 508 that will shut off the equipment served prior to overflow of the pan.The auxiliary drain pan shall be <br /> constructed in accordance with Item 1 of this section. <br /> A water-level detection device conforming to UL 508 shall be provided that will shut off the equipment served in the event that the primary drain is <br /> blocked.The device shall be installed in the primary drain line,the overflow drain line,or in the equipment-supplied drain pan,located at a point higher <br /> than the primary drain line connection and below the overflow rim of such pan. <br /> I <br /> Printed: Friday, 21 April,2023 1 of 2 <br /> SUPERION <br />
The URL can be used to link to this page
Your browser does not support the video tag.