- ' . ( ( <br /> � 5. The plans indicate a"refuse area"outside of the rear tavem e!cit. This area should be specified <br /> ' as an "area of evacuation assistance". The minimum concrete pad size is 48" x 60" per sec. <br /> 1104.2.2. The door is required to be protected by a door having a minimum of three-fourths <br /> hour fire-protection rating per sec. I 104.2.13. Plans should also indicate no changes in level <br /> greater then '/."unless accomplished by a ramp per sec. I 106.6. If a ramp is intended, provide <br /> details to comply with sec. I 106.8. The door schedule should requirc panic hardware at this <br /> rear exit. <br /> 6. The doors that exit from the apartments onro the sidewalk cannot swing mere then one foot <br /> beyond the property line(UBC 3207). Perhaps they could swing inward <br /> 7. The plans should indicate that the "covered area" will have no floor per fire department <br /> requirements. <br /> 8. Please expand the note to post the room capacity to read "post in a conspicuous place near the <br /> main exit doorway a sign stating"Maximum Occupant Load 200". <br /> 9. Please add to the plans "the owner shall employ the Sructural Engineer of record to perfortn <br /> structural observation of the plans and specifications at significant construction stages and at <br /> completion of the structural system. Structural observation dces not include or waive the <br /> responsibility for the jurisdictional inspections. Observed deficiencies shall be reported in <br /> writing to the owner, contractor and Building Official. The Engineer shall submit to the <br /> Building OfTcial a written statement that the site visits have been made and identifying any <br /> reported deficiencics that,to the best of the Engineer's knowledge, have not been resolved. <br /> Prepare a response lettcr showing where each item in this correction lener is addressed on the plan <br /> set. <br /> Upon submittal of the dmwings, your applicatiun will be given priority and plan review will <br /> recommPnce. <br /> All required submittnls shall be of sufficient detail and contain sufticient informatiun ro ensure that <br /> the proposed structure will be constructed in compliance with all adopred codes. <br /> Sincercly. � ,1,� �n <br /> c�.. ; r:�, �---, <br /> . <br /> � <br /> s<<�� Nru�� <br /> ASSOCI:IIC FI1L'I11C1`f <br /> ti���,jcIlU012.U0n <br /> ���� � - <br />