My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019 HEWITT AVE TURNERS TAVERN 2018-01-02 MF Import
>
Address Records
>
HEWITT AVE
>
2019
>
TURNERS TAVERN
>
2019 HEWITT AVE TURNERS TAVERN 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2023 10:41:39 AM
Creation date
4/24/2023 10:32:50 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2019
Tenant Name
TURNERS TAVERN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
February 21, 2001 <br /> RE: 2019 Hewitt Avenue <br /> B0012-006 <br /> Gross floor area: 645d square feet <br /> First Floor: 461 I square fect— A/B Occupancy <br /> Second floor: 1847 square feet - R-3B Occupancy <br /> Altematives I: Create a fire separation at the interior shear wall line usine two-hour tire <br /> resistive construction. The fire separation would follow the wall line as it returns to the <br /> east side of the building. The flre separation would include the following; <br /> • encapsulating the columns and beams with two-hour fire resistive construction <br /> material <br /> • constructing the tloor ceiling members spannin� between the shear wall and the <br /> column line with two-hour fire resistive construction <br /> • The fire separation must extend through the crawl space with two-hour fire resis:ive <br /> construction <br /> • The fire separation must extend through the second floor with two-hour fire resistive <br /> construction including any offsets caused by differing wall alignment between the <br /> first and second floors <br /> • The Cre separation must continue through the roof with a parapet or the one-hour fire <br /> resistive construction over the entire ceiling if the framing is parallel to the wall and <br /> two-hour fire resistive construction horizontally for five feet on both sides of the wall <br /> line to include the roof framing members if the framina is perpendicular to the wall <br /> • Openings in the fire separation are limited to 2590 of the len,th of the wall and must <br /> be protected by 90 minute fire resistive assemblies � <br /> Alternative II: Creare a fire separation wall of two-hour fire resistive conswction. The <br /> separation line could be located at the east west interior wall line [grid line D� on the first <br /> Floor�nd continue west to the kitchen. The separation could enclose the kitchen and <br /> cooler and terminate and the west exterior wall. <br /> An openin� could remain alone the �rid Iine between the customer booth and the kitchen <br /> if protected by a 90-minute fire resistive assembly. The door leafs could remain in an <br /> open position if held open by magnetic devices activated by the automatic fire alarm <br /> system. <br /> The separation must continue throueh the second Floor as described in Alternative I. <br /> Alternative III: Create a stairway shaft in the NE corner of the buildin�. The size of the <br /> shaft must be a minimum of d54 squam feet. The shaft could not contain a second floor. <br /> ���� <br />
The URL can be used to link to this page
Your browser does not support the video tag.