My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
900 PACIFIC AVE OB GYN 5TH FLOOR 2018-01-02 MF Import
>
Address Records
>
PACIFIC AVE
>
900
>
5TH FLOOR
>
900 PACIFIC AVE OB GYN 5TH FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2025 9:07:57 AM
Creation date
4/25/2023 2:24:13 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
900
Unit
OB GYN
Tenant Name
5TH FLOOR
Notes
EVERETT CLINIC OB - GYN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, . . . <br /> � g � � <br /> � � � � <br /> F 9 � Complete plans and specifications for the fire alarm system installation or modification <br /> shall be submitted for review and approval prior to system installation. Plans and <br /> specifications shall include,but not be limited to,a tloor plan; location of all alarm- <br /> initiating and alarm-signaling devices; alazm-control and troublo-signaling equipment; <br /> annunciation;power connection;battery calculations;conductor type and sius;voltage <br /> drop calculations; name,address,and phone number of the agency receiving off- <br /> prcmises transmission of alarm; and the manufacturer,model numbers and listing <br /> infortnation for all equipment,devices,and materials. Inco ete Qlans and <br /> scecificasions will be rotumed wi�hout review. Plans and specifications may be <br /> submitted separately from conswction documents during the conswction of the <br /> project. For small renovation projects in which devices arc only to be relocatcd,a plan <br /> that shows the relocation of devices can be submitted for review in liou of the above <br /> requirements. Sec. 1001.3,Unifortn Firo Code <br /> p 10 � Provide revised drawings revising Hallway 112A to a deadend of twenty feet or less. <br /> WAC 246-320.525(2), Sec. 1004.2.6 Uniform Building Code <br /> A l 1 � Provide revised drawings with proper dimensions to show that Exams 113A, l 18A,and <br /> 119A have at least 80 square fxt of floor area. WAC 246-320-815(S)(d)(i) <br /> p 12 � Provide revised drawings showing how patient privacy will be provided at Exams <br /> 118A, 119A, 128A, and Treatment 132A. WAC 246-320-245(21(a)(i) <br /> yl� <br /> Page 4 of 4 Plan Review Corturcnts for Pro�ect N 6448 <br /> Review Kcy: A=Architect F=Fi�e&Life Safny S=Sanitarian M=MecAnical/Blectrial C e Confaena Na1e <br />
The URL can be used to link to this page
Your browser does not support the video tag.