Laserfiche WebLink
C � <br /> x O $ <br /> F $ g> <br /> aG � � Z <br /> p 8 m Sprinkler system working plans shall be submitted for approval before any equipment <br /> is installed or remodeled. D�viation from approved plans will require pertnission. <br /> R'orking plans shall contain all data as indicated in Section 1-9.2,Unifortn Building <br /> Code Standard No. 38-1. Plans and sQecifications includin¢hvdraulic calculations. <br /> that are incomQlete or are not stamoed bv a Washineton State Licenscd Fire�S nnkler <br /> Contractor.will be retumed without review. Plans and spec�ficatwns may be <br /> submitted separately from cons:ruction documents during the conswction of the <br /> project. For small renovation projects in which heads are only to be relocated,a plan <br /> that shows the relocation of devices can be submitted for review in lieu of the above <br /> requirements. Sec. ]001.3,Uniform Fire Code i <br /> Noted on submission 002 received 5/29/2002 that fire sprinkler plans will be <br /> submitted separately. <br /> 8.1 Two sprfnkler heads shown in Hallway 111A at tMe intersecdon of Iiellway 121A <br /> are too close together.Please review and revise the sprinkler spacing. <br /> Sec. 5-7.3.4,NFPA 13 <br /> F 9 � Complete plans and specifications for the fire alartn system installation or <br /> modification shall be submitted for review and approval prior to system installation. <br /> Plans and specifications shall include,but not be limited to,a Floor plan; location of <br /> all alarm-initiating and alarm-signaling devices; alarm-control and trouble-signaling <br /> equipment; annunciation; power connection;battery calculations;conductor type and <br /> sizes; voltage drop calculations; name, address, and phone number of the agency <br /> receiving off-premises transmission of alartn; and the manufacturer, maiel num;�ers <br /> and listing information for all equipment, devices,and materials. Inca�lete plans <br /> and s�e�i6cations will be rewmed without review. Plans and specifications may be <br /> submitted separately from conswction documents during the wnstruction of the <br /> project. For small renovation projects in which devices are only to be relocated, a I <br /> plan that shows the relocation of devices can be submitted for review in lieu of the � <br /> above requirements. Sec. 1001.3, Uniform Fire Code <br /> Noted on submission 002 received 5/29/2002 that fire alartn plans will be submitted <br /> scparately. Please note that a review of sheet E2.0 indicated that fire alarm strobe <br /> devices would be required in Staff Lounge 133A and Behavioral Health 135A and <br /> 136A. <br /> 9.1 � Not approved 12/10/2002 besed on plans received 11/27/2002.I'rovide alrrm <br /> strobes in Behevioral Health 135A and 136A. Sec. 1106.15.2, Uniform Bullding <br /> Code—Washington State Amendments <br /> M� <br /> Pagc 4 of 5 Plan Review Comments for Project#6448 <br /> Rcvicw Kcy: A=Archi�cct 1'=Pirc&Li(c Safcry S=Sanitarian M=Mcchanical/Elcctrical C=Confercna Ndt <br />