My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2138 W MUKILTEO BLVD 2023-05-11
>
Address Records
>
W MUKILTEO BLVD
>
2138
>
2138 W MUKILTEO BLVD 2023-05-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2023 11:11:17 AM
Creation date
5/4/2023 7:35:10 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
2138
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Bosch 1 BOVB 18 Product <br /> 3 Product Specifications <br /> Decibels([dB(A)] <br /> Max @ 100° load 79 <br /> Min @ min load 56 60 <br /> Compressor <br /> RLA 19 29 <br /> LRA 45 58.1 <br /> Condenser Fan Motor <br /> Horsepower(HP) 1/6 1/3 <br /> FLA 1.0 2.5 _ <br /> Refrigeration System _ <br /> Refrigerant Line Size' <br /> Liquid Line Size(OD) 3/8" 3/8" <br /> Suction Line Size(OD) 3/4" 7/8" <br /> Refrigerant Connection Size <br /> Liquid Valve Size(OD) 3/8" 3/8" <br /> Suction Valve Size(OD) 3/4" 7/8" <br /> Refrigerant Charge(R410-A,oz) 121 170 <br /> Expansion Device EEV EEV <br /> Maximum Line Length 100 FT 100 FT <br /> Maximum Elevation Difference 50 FT 50 FT <br /> Operating Range <br /> Cooling 40"F-125"F <br /> Heating 5"F-86"F <br /> Electrical Data <br /> Voltage-Phase-Hz 208/230.1-60 208/230-1.60 <br /> Minimum Circuit Ampacity' 24.8 38.8 <br /> Max.Overcurrent Protection' 40 60 <br /> Min/Max Volts 172V/270V <br /> Weight <br /> Net Weight(without packaging) 159 196 <br /> Gross Weight(including packaging)' 190 227 <br /> Dimensions <br /> Unit L x W x H(in.) 29.1/8 x 29-1/8 x 24-15/16 29.1/8 x 29-1/8 x 33-3/16 <br /> Outdoor Coil <br /> Net face area-sq.ft.Outer Coll 13.6 18.4 <br /> Tube diameter-in. 9/32"(7mm) 9/32"(7mm) <br /> No.of rows 2 2 <br /> Fins per inch 17 19 <br /> Table 1 <br /> 'Tested and rated in accordance with AHRI Standard 210/240. <br /> 'Wire size should be determined in accordance with National Electrical Codes; <br /> extensive wire runs will require larger wire sizes. <br /> 'Must use time-delay fuses or HACK-type circuit breakers of the same size as <br /> noted. <br /> Always check the rating plate for electrical data on the unit being <br /> 'Weight values are estimated. installed. <br /> 1 •Unit is factory charged with refrigerant for 15'of W liquid line. <br /> System charge must be adjusted per Installation Instructions Final <br /> Charge Procedure. <br /> •TXV is required at indoor unit to match our outdoor unit. <br /> Data subject to change 12.2020 1 Bosch Thermotechnology Corp. <br />
The URL can be used to link to this page
Your browser does not support the video tag.