Laserfiche WebLink
SCOPE OF WORK: <br />TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC <br />SYSTEM AT THE OWNER RESIDENCE LOCATED AT <br />1410 WEST MUKILTEO BLVD EVERETT, WA 98203. <br />THE POWER GENERATED BY THE PV SYSTEM WILL BE <br />INTERCONNECTED WITH THE UTILITY GRID THROUGH THE <br />EXISTING ELECTRICAL SERVICE EQUIPMENT. <br />THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. <br />GENERAL NOTES: <br />EQUIPMENT SUMMARY <br />24 Q CELL Q.PEAK DUO BLK ML-G10+ (40OW) MODULES <br />24 ENPHASE IQ8PLUS-72-2-US(24OV) MICROINVERTERS <br />• THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND <br />OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE <br />MODIFICATIONS IN CONSTRUCTION DETAILS. <br />• ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR <br />INSTALLATION OF ANY EQUIPMENT AT SITE. <br />• CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL <br />PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. <br />• CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS <br />AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER <br />BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION <br />AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE <br />CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL <br />COMPENSATION. <br />• DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, <br />FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE <br />CONTRACTOR AT NO ADDITIONAL COST. <br />• THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND <br />COMPLETION OF THE WORK WITH APPROVED MATERIALS. <br />• NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE <br />ARCHITECT. <br />• CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING <br />PERMIT IS PROPERLY DISPLAYED. <br />• ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE <br />WITH THE REQUIREMENTS OF THE WA BUILDING CODE, THE DEPARTMENT OF <br />ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. <br />• IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL <br />PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. <br />THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. <br />• ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO <br />BE PAINTED BY GENERAL CONTRACTOR. <br />• THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE <br />LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. <br />• THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, <br />CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. <br />• CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. <br />ELECTRICAL NOTES: <br />GOVERNING CODES <br />2018 INTERNATIONAL RESIDENTIAL CODE <br />2018 INTERNATIONAL BUILDING CODE <br />2018 INTERNATIONAL FIRE CODE <br />2020 NATIONAL ELECTRICAL CODE <br />WASHINGTON ADMINISTRATIVE CODE (WAC) <br />WIRING AND CONDUIT NOTES: <br />• ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS <br />PURPOSE AND APPROVED FOR THE SITE APPLICATIONS <br />• ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV <br />WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, <br />OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER <br />BOXES AS REQUIRED <br />• ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED <br />ACCORDING TO [NEC 690.8 (A)(1) & (B)(1)], [NEC 240] [NEC <br />690.7] FOR MULTIPLE CONDUCTORS <br />• ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT <br />SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 <br />(B)(2)(C)] BLACK ONLY" <br />• EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C <br />RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR <br />600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT <br />WIRE FROM SHARP EDGES <br />• 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH <br />THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR <br />IDENTIFIED BY OTHER EFFECTIVE MEANS <br />• ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE <br />CIRCUIT PROTECTION <br />• VOLTAGE DROP LIMITED TO 2% <br />• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE <br />A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, <br />NEUTRAL- WHITE/GRAY <br />• THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS <br />ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS <br />AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(C), NEC 2020) <br />• LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP <br />CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. <br />• NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE <br />COORDINATION REQUIREMENTS OF OTHER TRADES. <br />• ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. <br />• ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (NEC 690), NEC 2020. <br />• WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED <br />DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING <br />• BACK -FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. <br />• ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. <br />• CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 <br />• PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTION, AND SPLICES. THE MEANS OF ID <br />CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4), NEC 2020. <br />• MEASURE THE LINE -TO -LINE AND LINE -TO -NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR <br />EQUIPMENT. THE VOLTAGES FOR THE 240VAC RATED. <br />SYSTEM RATING <br />9.60 KWDC <br />7.20 KWAC <br />SHEETINDEX <br />PV-0 <br />COVER PAGE <br />PV-1 <br />SITE PLAN <br />PV-2 <br />ROOF PLAN & MODULES <br />PV-2A <br />STRING LAYOUT & BOM <br />PV-3 <br />ATTACHMENT DETAIL <br />PV-3A <br />ATTACHMENT DETAIL <br />PV-4 <br />ELECTRICAL LINE DIAGRAM & CALCS. <br />PV-4A <br />SPECIFICATIONS & CALCULATION <br />PV-5 <br />SIGNAGE <br />PV-6+ <br />EQUIPMENT SPECIFICATIONS <br />IN <br />1 HOUSE PHOTO SCALE: NTS <br />PV-0 <br />PROJECT SITE <br />Everett <br />PORT GARDNER <br />1410 W Mukilteo Bivd <br />Everett, VNA 98203,.USA <br />i <br />I <br />v <br />PINEHURST-BEVEF <br />PARK <br />2 VICINITY MAP SCALE: NTS <br />PV-0 <br />J ct) <br />0 0� <br />J 7 <br />oco <br />SYSTEM INFO. <br />(24)Q CELL Q.PEAK DUO BLK ML-G10+ <br />(40OW) <br />(24) ENPHASE IQ8PLUS-72-2-US(240V) <br />DC SYSTEM SIZE: 9.60 KWDC <br />AC SYSTEM SIZE: 7.20 KWAC <br />REVISIONS <br />DESCRIPTION <br />DATE <br />REV <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />Z 0 <br />J <br />O <br />O <br />m <br />J uJ O cal <br />o <br />ao <br />U wrn <br />o <br />Q ZLU <br />o <br />>Q <br />> <br />C) <br />O <br />H <br />c) <br />F—J <br />o <br />LUC)f <br />.. <br />Z 3: w <br />z <br />Z o <br />Q <br />Q <br />DATE: 07/06/2022 <br />SHEET NAME <br />COVER PAGE <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-0 <br />