DESIGN SPECIFICATION <br />RISK CATEGORY: <br />II <br />CONSTRUCTION: <br />SFD <br />ZONING: <br />RESIDENTIAL <br />SNOW LOAD (ASCE 7-16): <br />25 PSF <br />EXPOSURE CATEGORY: <br />C <br />WIND SPEED (ASCE 7-16): <br />110 MPH <br />MODULE TYPE, DIMENSIONS & WEIGHT <br />NUMBER OF MODULES: <br />24 MODULES <br />MODULE TYPE: <br />Q CELL Q.PEAK DUO <br />ML-G10+ (400W) <br />MODULE WEIGHT: <br />48.5 LBS <br />MODULE DIMENSIONS: <br />74.0" x 41.1" = 21.12S <br />UNIT WEIGHT OF AREA: <br />2.30 PSF <br />MODULE, ARRAY WEIGHT (LOAD <br />CALC'S) <br />Number of Modules <br />24 <br />Module Weight <br />48.50 <br />LBS <br />Total Module (Array) Weight <br />1164.00 <br />LBS <br />Number of Attachment point <br />54 <br />Mounting System Weight <br />(Per Module) <br />0.50 <br />LBS <br />Total Mounting System Weight <br />27.00 <br />LBS <br />No. of Racking <br />13.00 <br />Racking system Weight <br />6.89 <br />LBS <br />Total Racking system Weight <br />89.57 <br />LBS <br />Total System Weight <br />(Total Module Weight +Total Mounting System Weight +Total <br />Racking System Weight) <br />1280.57 <br />LBS <br />Weight at Each Attachment Point <br />(Array Weight / Number of Attachment Point) <br />21.56 <br />LBS <br />Module Area (74.0"x41.1") <br />21.12 <br />SgFt <br />Total Array Area <br />506.88 <br />SgFt <br />Distributed Load <br />(Total System Weight / Total Array Area) <br />2.53 <br />Per <br />Sq Ft <br />Total Roof Area <br />2083.00 <br />SgFt <br />Total Percentage or Roof Covered <br />Total Array Area / Total Roof Area)*100 <br />24.33% <br />1 1 ROOF PLAN i MODULES <br />ROOF DESCRIPTION <br />ROOF <br />ROOF RAFTER RAFTER <br />AZIMUTH ROOF MATERIAL <br />TILT SIZE SPACING <br />#1 <br />23° 210° 2"X4" 24" o.c. COMP. SHINGLE <br />I <br />#2 <br />23° 120° 2"X4" 24" o.c. COMP. SHINGLE <br />TR�y <br />(N) IQ COMBINER BOX <br />#3 <br />23° 300° 2"X4" 24" COMP. SHINGLE <br />12i�T 203 <br />(N) NON -FUSED AC DISCONNECT <br />0/k- <br />o.c. <br />300° <br />(E) UTILITY METER <br />ARRAY AREA & ROOF AREA CALC'S <br />�/� <br />ARRAY ROOF ROOF <br />(b <br />(N) MAIN SERVICE PANEL <br />C� <br /># OF AREA AREA AREA <br />ROOF <br />MODULES COVERED BY <br />(Sq. Ft.) (Sq. Ft.) <br />6 F <br />ARRAY (%) <br />,qC <br />#1 8 168.96 410.00 41.21 <br />/✓M <br />#2 8 1 168.96 1 368.00 1 45.91 <br />#3 8 1 168.96 1443.00 1 38.14 <br />r18 <br />70 <br />(N) JUNCTION BOX <br />;'2, <br />M <br />(N) UNIRAC SOLARMOUNT LIGHT RAIL <br />gZIq�Q9y2 (54) RT MINI II @ 48" o.c. <br />M jp°(24) ENPHASE IQ8PLUS-72-2-US(240V) MICROINVERTERS - <br />2 <br />%F ROOFS #1, #2 & #3 <br />pO (24) Q CELL Q.PEAK DUO BLK ML-G10+ (400W) MODULES <br />�T O <br />0 <br />LEGEND <br />u (N) JUNCTION BOX <br />UM (E) UTILITY METER <br />MS (N) MAIN SERVICE PANEL (MSP) <br />AC (N) NON -FUSED AC DISCONNECT <br />® (N) IQ COMBINER BOX <br />p ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION) <br />-ROOF ATTACHMENT <br />4. <br />0 <br />Q CELL Q.PEAK <br />DUO BLK ML-G10+ <br />(400W) MODULES <br />I <br />� <br />�Q <br />O <br />J CO <br />•� o o� <br />g v <br />J 00 <br />C] 00 <br />Lo <br />:3 <br />SYSTEM INFO. <br />(24)Q CELL Q.PEAK DUO BLK ML-G10+ <br />(400W) <br />(24) ENPHASE IQ8PLUS-72-2-US(240V) <br />DC SYSTEM SIZE: 9.60 KWDC <br />AC SYSTEM SIZE: 7.20 KWAC <br />REVISIONS <br />DESCRIPTION <br />DATE <br />REV <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />Z o <br />O J <br />O <br />mo <br />J Lu O cal <br />o <br />00 <br />U wrn <br />O <br />Q Z _j Q <br />O <br />= <br />p ��: <br />o <br />F— <br />� <br />U <br />o <br />W O <br />W 0� LU W <br />Z Ow <br />0- <br />Q <br />Q <br />DATE: 07/06/2022 <br />SHEET NAME <br />ROOF PLAN <br />& <br />MODULES <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-2 <br />