Laserfiche WebLink
MICROINVERTER ilr <br /> Use IronRidge's Microinverter Kit to bond compatible <br /> microinverters and power optimizers to the racking system. one Microinverter <br /> Kit Required <br /> Insert Microinverter Kit T-bolt into top rail slot. Place (80 in-lbs) <br /> compatible microinverter or power optimizer into position <br /> and tighten hex nut to 80 in-lbs. <br /> ➢ If installing in areas with ground snow loads greater than 40 psf, <br /> install MLPE devices directly next to module frame edge <br /> COMPATIBLE PRODUCTS ------------------ <br /> Enphase <br /> M250-72,250-60,M215-60,C250-72,S230,S280, IQ 6,IQ 6+,IQ <br /> IQ7,IQ 7A,IQ 7+,IQ7 PD, IQ 7X,Q Aggregator; IQ8-60, _ <br /> IQ8PLUS-72,IQ8A-72,IQ8H-208-72,IQ8H-240-72,IQ8M-72,may be <br /> followed by-2-US <br /> Darfon <br /> MIG240,MIG300,G320,G640 <br /> Solar Edge <br /> M1600, P300, P320,P340, P370,P400,P401, P405,P485, P505, <br /> P600, P700, P730,P750, P800p,P800s,P801, P850,P860,P950, <br /> P960, P1100, P1101,S440,S500,S1200,S1201 <br /> SMA <br /> RoofCommKit-P2-US,TS4-R Module Retrofit Kits(TS4-R-S,TS4- _ <br /> R-O,TS4-R-F) <br /> On AP systems equipment, <br /> Tlgo remove Grounding Washer <br /> Tigo Access Point(TAP) <br /> TS4-R-X(where X can be F,M,O,or S) <br /> TS4-R-X-DUO(where X can be M,O,or S) <br /> TS4-A-X(where X can be F,2F,O,O-DUO,or S) Al <br /> l <br /> Generac <br /> S2502 Two icroinverter <br /> - - - -- _ - Kits Required <br /> in-lbs) <br /> AP Systems <br /> DS3,QS1,QT2 and YC600 <br /> NEP <br /> BDM-300,BDM-300X2 and BDM-800 <br /> ➢ Remove Grounding Washer on AP Systems QS1,QT2, DS3 and YC600 inverters before installing to XR rails. <br /> ➢ Remove the Stainless Steel Clip on Tigo-"A"MLPE Devices before attaching to XR rails. <br /> ➢ Use the number of Iron Ridge Microinverter kits allowed by the MLPE mounting flange.Some will require 1 <br /> kit and others 2 kits. <br /> Ak <br /> IronRidge systems using approved Enphase products or SunPower modules eliminate the need for lay-in lugs and field <br /> installed equipment grounding conductors (EGC). This solution meets the requirements of UL 2703 for bonding and <br /> grounding and is included in this listing. <br /> COMPATIBLE PRODUCTS <br /> Sunpower <br /> Modules with model identifier Ab-xxx-YY and InvisiMount(G5)46mm frame;where"A"is either E,or X; "b"can be 17, 18,19,20,21,or 22; <br /> and"YY"can be C-AC,D-AC,BLK-C-AC,or BLK-D-AC. <br /> Enphase <br /> Microinverters M250-72,M250-60,M215-60,C250-72,and Engage cables ETXX-240,ETXX-208, ETXX-277. <br /> ➢ A minimum of two inverters mounted to the same rail and connected to the same Engage cable are required. <br /> ➢ The microinverters or Sunpower AC modules must be used with a maximum 20 A branch rated overcurrent protection device(OCPD). <br /> ➢ If an AC module is removed from a circuit for maintenance,you must first disconnect AC power and then install a temporary EGC to <br /> bridge the gap by inserting an AC extension cable(or via other NEC-compliant means), in order to maintain effective ground continuity <br /> to subsequent modules. <br />