Laserfiche WebLink
1 8 <br /> (4)Shielded LINE <br /> #24 AWG M <br /> 2 CTs(Untwisted Pairs) LOAD <br /> 1 <br /> 3 ------------ ———, I <br /> I I <br /> I I <br /> I I Enphase IQ <br /> I Combiner Panel 1 <br /> 4 I <br /> 1O I 3 Junction 3 1 I <br /> jBox AC Disconnect I <br /> I <br /> I 1sn .- I <br /> zon <br /> 2 I aon Load ine 200A MAIN O <br /> 1 <br /> -----, I �— -- I 225A BUS <br /> 3 <br /> I I I 6 I 60A OCPD <br /> 5 60A MAIN <br /> 125A BUS <br /> 4 I <br /> 5 I <br /> 40A OCPD <br /> I <br /> (Interior Garage) <br /> I <br /> I <br /> Combined Inverter <br /> Max Output with <br /> _ 6 <br /> Safety Factor 30.25 <br /> Amps <br /> ARRAY SPECIFICATIONS Q CONDUIT AND CONDUCTOR SCHEDULE <br /> ModuleTAG COND. NUMBER OF CONDUIT CONDUIT <br /> Ratings <br /> Design Temp Combined Array Specs DESCRIPTION OF CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE <br /> Q.PEAK DUO BLK ML-G10 Hot 29°C 8 kW 1 Cables Listed with Module 12 AWG 2 Black N/A N/A <br /> Imp 10.77 A Nom 24°C 40OW Qcells Modules 2 THHN THWN-2 12 AWG 1 B(1-1), 1 R(1-2), 1 G#12(EGC) EMT 3/4" <br /> Isc 11.14 A Cold -17°C 20 Modules 3 THHN THWN-2 12 AWG 2 B(1-1),2 R(L2), 1 G#12(EGC) EMT 3/4" <br /> Vmp 37.13 V TcVoc -.27%/°C (1)Circuits of(11)Modules 4 THHN THWN-2 8 AWG 1 B(1-1), 1 R(1-2), 1 W(NEUT), 1 G#10(GND) EMT 3/4" <br /> Voc 42.72 V MaxVoc 47.6 V (1)Circuits of(9)Modules 5 ITHHN THWN-2 8 AWG 1 1 B(1-1), 1 R(1-2), 1 W(NEUT), 1 G#10(GND) EMT 3/4" <br /> (1)Micro-inverter per module. 6 1GROUNDING ELECTRODE COND 6 AWG Bare 1 CU N/A N/A <br /> Inverter Inverter <br /> Ratings Ratings <br /> IQ7PLUS-72-2-US IQ7PLUS-72-2-US <br /> Inverters 11 Inverters 9 O EQUIPMENT SCHEDULE <br /> Output 240 V Output 240 V <br /> Output 1.21A Output 1.21A TAG EQUIPMENT LOCATION DESCRIPTION <br /> String A 13.31 A String A 10.89 A <br /> 1 SOLAR PV MODULE South, East&West Roofs of Garage 8kW System: 20 Qcells Modules;40OW Each;Q.PEAK DUO BLK ML-G10 <br /> 2 PV ARRAY South, East&West Roofs of Garage 20 Modules:See Array Specifications for String Info <br /> PV AC Circuit 3 MICRO-INVERTERS Underneath Each Module 20 Enphase Micro-inverters: 1 IQ8PLUS-72-2-US Microinverter per Module; RSD Compliant <br /> Nominal Voltage 4 JUNCTION BOX Mounted Underneath Array NEMA 313 <br /> Imax 5 AC COMBINER PANEL Exterior Garage Wall 240V En hase IQ Combiner 4 Panel; NEMA 3R; 1 20A Breaker; 1 15A Breaker <br /> 240 v 6 AC DISCONNECT North Exterior Garage Wall 240V Disconnect;Visible Lockable Break; Heavy Duty; 60A Rated <br /> 24.2 A <br /> 7 200AMP MAIN SERVICE PANEL Interior House Wall 240 VAC 200AMP MAIN,225AMP BUS <br /> 7a SUBSERVICE PANEL Interior Garage Wall240 VAC, 60AMP MAIN, 125AMP BUS <br /> 8 1 UTILITY METER North Exterior House Wall lExisting Sno PUD Meter#: 1000912887 <br /> _ One-Line Standard Electrical Diagram for SYSTEM SIZE AE JOB NO. DWG NO REVISION <br /> ' • Small-Scale, Single-Phase PV System 8 kW 22-10761-R E1.1 3 Drawn By: Chiva Chun <br /> 969 S Nebraska St <br /> ARTISAN Seattle, WA 98108 Site Name:Michelle Quade Photovoltaic System <br /> 206-557-4215 Site Address: 2314 Baker Ave Everett, WA 98201 Scale: NTS Sheet 1 Date: 3/1/2023 Checked By: Joey MacLennan <br /> System AC Size: 8 kW Solar Array <br />