My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5631 EVERGREEN WAY 2023-05-09
>
Address Records
>
EVERGREEN WAY
>
5631
>
5631 EVERGREEN WAY 2023-05-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2023 3:07:23 PM
Creation date
5/9/2023 2:50:35 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5631
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Honeywell <br />®SILENT' <br />KNIGHT <br />5495 <br />Distributed Power Module <br />The 5495 Distributed Power Module is the most powerful and cost- <br />effective power supply available today. It delivers 6 amps of notification <br />appliance circuit power and built-in synchronization for appliances from <br />System Sensor°,Gentex°, AMSEC01, and Wheelock. The 5495's switch <br />mode power supply design is up to 50% more efficient than competitive <br />linear mode power supplies. Also, ADA retrofits are easier and less <br />expensive with the 5495 because it integrates into current systems <br />without the costly investment in new components. <br />The 5495 is a 6 amp notification power expander that provides its own AC <br />power connection, battery charging circuit, and backup battery. The 5495 <br />is the costeffective solution for powering notification appliances required <br />by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI <br />cadence pattern, which can upgrade older control panels that lack <br />cadence capability. <br />ld•] 2I Z I *A i[ •] 2 i 11•7 K•Z•fe19 d 1:]mo416] 2 Y d:Z•] 11 <br />The 5495 may be connected to a local fire controlwhich utilizes Class A or <br />Class B type notification circuits operating between 9 and 32 VDC. The <br />control panel's notification circuit is connected to one of the inputs on the <br />5495. The control panel's notification circuit end -of -line resistor is also <br />connected across two terminals on the 5495, which provides supervision <br />between the 5495 and the fire control panel. Polarized audible and/or <br />visual notification devices are then connected to the 5495 signal circuits <br />using the 4.7kn end -of -line resistors provided. Since the 5495 draws very <br />little power from the control, it is possible to connect one 5495 to each <br />notification circuit on the control panel and still provide full supervision of <br />the notification circuits all the way back to the control panel. <br />FEATURES & BENEFITS <br />• UL Listed for 6 amps <br />of notification power <br />• Power supply's <br />advanced switch mode <br />design reduces <br />damaging heat and <br />manages power up to <br />50% more efficiently <br />than other systems <br />• Dip switches allow for <br />easy reconfiguration <br />• 24 VDC filtered output <br />voltage <br />• Four power -limited <br />notification outputs; 2 <br />Class A or 4 Class B, or <br />1 Class A and 2 Class <br />B <br />• Additional continuous <br />auxiliary output <br />• 3 amps per output <br />circuit <br />• 2 inputs; 2 Class B or 2 <br />Class A <br />• Ground fault detector/ <br />indicator <br />• Independent trouble <br />relay <br />• AC loss delay option <br />shuts off power to <br />non -essential <br />high -current <br />accessories like <br />magnetic door holders <br />5495 <br />• Built-in <br />synchronization for <br />appliances from <br />System Sensor', <br />Gentex®, AMSECO', <br />and Wheelock <br />• Stand alone operation <br />• Lightweight design <br />adds to ease of <br />installation and <br />reduces shipping <br />costs <br />• Operates with most <br />polarized, UL Listed <br />notification devices <br />• ANSI Cadence pattern <br />output capability <br />built-in <br />
The URL can be used to link to this page
Your browser does not support the video tag.