My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5631 EVERGREEN WAY 2023-05-09
>
Address Records
>
EVERGREEN WAY
>
5631
>
5631 EVERGREEN WAY 2023-05-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2023 3:07:23 PM
Creation date
5/9/2023 2:50:35 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5631
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications <br />Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for <br />Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single -circuit or a dual -circuit type, normally open. The <br />detector shall be rated for activation at either 135°F (57°C) or 194°F (90oC), and shall activate by means of a fixed temperature thermal sensor, <br />or a combination fixed temperature/rate-of-rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, <br />approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch <br />octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of <br />SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to <br />identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature/rate-of-rise models shall be <br />restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. <br />Physical/Operating <br />Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100°F (38°C) <br />5602, 5604, 5622, and 5624: 150OF (65.6°C) <br />Operating Humidity Range 5 to 95% RH non -condensing <br />Dimensions with mounting bracket <br />Diameter: 4.57 inches (11.6cm) <br />Height: 1.69 inches (4.3cm) <br />Alarm Temperature <br />5601 P, 5603, 5621, and 5623: 135°F (57°C) <br />5602, 5604, 5622, and 5624: 194°F (90°C) <br />Weight <br />6 oz. (170 grams) <br />Rate -of -Rise Threshold <br />15°F (8.3°C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) <br />Mounting <br />31/2-inch octagonal back box <br />4-inch octagonal back box <br />Single gang back box <br />4-inch square back box with a square to round plaster ring <br />Electrical Specifications <br />Operating Voltage / Contact <br />6-125VAC / 3A <br />Ratings <br />6-28VDC / 1 A <br />125VDC / 0.3A <br />250VDC / 0.1A <br />Input Terminals <br />14-22 AWG <br />"yd <br />(D <br />5601 P 5602, 5622 5603, 5623 5604, 5624 5621 <br />Ordering Information <br />5601 P <br />Single <br />None <br />135°F (57°C) <br />Fixed Temperature / Rate -of -Rise <br />50 feet x 50 feet (15.24m x 15.2m) <br />5602 <br />Single <br />Lettering <br />194°F (90°C) <br />Fixed Temperature / Rate -of -Rise <br />50 feet x 50 feet (15.24m x 15.2m) <br />5603 <br />Single <br />Lettering <br />135°F (57°C) <br />Fixed Temperature <br />25 feet x 25 feet (7.62m x 7.62m) <br />5604 <br />Single <br />Lettering <br />194°F (90°C) <br />Fixed Temperature <br />25 feet x 25 feet (7.62m x 7.62m) <br />5621 <br />Dual <br />Lettering <br />135°F (57°C) <br />Fixed Temperature / Rate -of -Rise <br />50 feet x 50 feet (15.24m x 15.2m) <br />5622 <br />Dual <br />Lettering <br />194°F (90°C) <br />Fixed Temperature / Rate -of -Rise <br />50 feet x 50 feet (15.24m x 15.2m) <br />5623 <br />Dual <br />Lettering <br />135°F (57°C) <br />Fixed Temperature <br />25 feet x 25 feet (7.62m x 7.62m) <br />5624 Dual Lettering <br />`NOTE: Refer to NFPA72 guidelines for <br />194°F (90°C) Fixed Temperature <br />spacing reductions when ceiling heights exceed 10 feet. <br />25 feet x 25 feet (7.62m x 7.62m) <br />SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2013System Sensor. <br />Product specifications subject to change without notice. Visit systemsensorcom <br />Phone: 800 SENSOR2 •Fax: 630 377 6495 or current product information, including the latest version of this data sheet. <br />SENSOR" <br />www.systemsensor.com SPDS30001.7/13 <br />