Laserfiche WebLink
Abbreviations Legend <br />AT <br />AIR CONDITION(ING) (ED) <br />UNIT AIR CONDITIONING UNIT <br />ANCHOR BOLT <br />VR ABBREVIATION <br />;U AIR COOLED CONDENSING UNIT <br />AREA DRAIN, ACCESS DOOR <br />AMERICANS WITH DISABILITIES ACT <br />IL ADDITIONAL <br />IM ADDENDUM <br />ARCHITECT/ ENGINEER <br />AUTOMATIC FLOW CONTROL <br />ABOVE FINISHED FLOOR <br />AIR HOSE REEL <br />AIR HANDLING UNIT <br />ALTERNATE <br />ACCESS PANEL <br />;H ARCHITECT(URAL) <br />AIR SEPARATOR <br />BACK-TO-BACK <br />BLOW DOWN <br />BUILDING <br />BENCHMARK, BEAM <br />BOTTOM <br />BRONZE <br />BASEMENT <br />BRITISH THERMAL UNIT <br />BETWEEN <br />BALANCING VALVE <br />BACKWATER VALVE <br />CATCH BASIN <br />CONDENSATE DRAINAGE <br />CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED <br />CONTRACTOR FURNISHED/ OWNER INSTALLED <br />CASTIRON <br />CENTER LINE <br />CEILING <br />CLEAR <br />CONCRETE MASONRY UNIT <br />CLEANOUT <br />COLUMN <br />CONCENTRATE, CONCRETE <br />CONDENSATE <br />CONNECT(ION), CONNECT <br />CONTINUOUS <br />HYDRONIC CONVECTOR <br />COORDINATE, COORDINATION <br />CENTER <br />CONTROL <br />CABINET UNIT HEATER <br />COLD WATER, CASEMENT WINDOW <br />DRY BULB <br />DOUBLE <br />V <br />DOMESTIC COLD WATER <br />DEGREE <br />10 <br />DEMOLITION <br />DETAIL <br />DRINKING FOUNTAIN <br />DRAINAGE FIXTURE UNIT <br />V <br />DOMESTIC HOT WATER <br />VC <br />DOMESTIC HOT WATER CIRC. <br />or <br />DIAMETER <br />DIFFUSER <br />DIMENSION <br />F <br />DISTANCE <br />DOWN <br />DOZEN <br />DOWNSPOUT <br />DISH WASHER <br />a <br />DRAWING <br />DIRECT EXPANSION COOLING COIL <br />EAST <br />EACH, EXHAUST AIR <br />ELEVATION <br />ENCLOSURE <br />ENGINEER <br />ETHYLENE PROPYLENE DIENE MONOMER <br />EQUAL <br />EQUIPMENT <br />ETCETERA <br />ELECTRIC WATER COOLER <br />ELECTRIC WATER HEATER <br />EXCAVATE <br />EXHAUST <br />EXISTING <br />EXPAND, EXPANSION <br />EXTERIOR <br />IAbbreviations Legend <br />FACE-TO-FACE <br />FIRE ALARM CONTROL PANEL <br />FAN COIL UNIT <br />FLOOR DRAIN <br />FOUNDATION DRAINAGE <br />FINISH <br />FIXTURE <br />FLOOR <br />FOUNDATION <br />FUEL OIL RETURN <br />FUEL OIL SUPPLY <br />GENERATOR VENT <br />FIBERGLASS REINFORCED PLASTIC <br />FOOT, FEET <br />FOOTING <br />GAGE <br />GALLON <br />V GALVANIZED <br />V STL GALVANIZED STEEL <br />GENERAL CONTRACTOR <br />GARAGE DRAIN <br />GENERATOR EXHAUST <br />GENERATOR EXHAUST <br />I GENERAL, GENERATOR <br />GLASS, GROUND LEVEL <br />1 GYMNASIUM <br />HOSE BIBB <br />HANDICAP, HOLLOW CORE <br />HANDICAPPED <br />HEAVY DUTY <br />HOUR <br />HEIGHT <br />HEATING, VENTILATING AND AIR CONDITIONING <br />HOT WATER <br />INSIDE DIAMETER <br />INCHES <br />INCLUDE <br />INFORMATION <br />INSULATION <br />IRRIGATION WATER <br />JANITOR <br />CLO JANITOR CLOSET <br />1000 POUNDS <br />KITCHEN <br />LITER, ANGLE <br />LABORATORY <br />LAVATORY <br />LABEL <br />POUND <br />LINEAR FEET <br />LINEAR <br />MATCHLINE <br />RM MACHINE ROOM <br />MAINTENANCE <br />MATERIAL <br />MAXIMUM <br />MECHANICAL CONTRACTOR <br />MECHANICAL <br />RM MECHANICAL ROOM <br />MANUFACTURER <br />MINIMUM <br />MISCELLANEOUS <br />MILIMETER <br />NORTH <br />NOT APPLICABLE <br />NATURAL GAS <br />/ NATURAL GAS VENT <br />NOT IN CONTRACT <br />or# NUMBER <br />d NOMINAL <br />NOT TO SCALE <br />OXYGEN <br />ON CENTER <br />OUTSIDE DIAMETER <br />OI OWNER FURNISHED/ OWNER INSTALLED <br />:I OWNER FURNISEHD/ CONTRACTOR INSTALLED <br />IG OPENING <br />OPPOSITE <br />OPTIONAL, OPTIMUM <br />1 OVERFLOW ROOF DRAIN <br />IAbbreviations Legend <br />OVERFLOW RAIN LEADER <br />PLUMBING CONTRACTOR <br />PERFORATED <br />PUMPED GARAGE DRAIN <br />PLATE, PROPERTY LINE <br />PLUMBING <br />PANEL <br />PRELIMINARY <br />PARKING <br />PROJECT <br />PUMPED STORM <br />POUNDS PER SQUARE FOOT <br />POUNDS PER SQUARE INCH <br />POST TENSIONED <br />POLYVINYL CHLORIDE (PLASTIC) <br />PUMPED WASTE <br />POWER <br />QUARTER <br />QUANTITY <br />RISER, RADIUS, HEAT RESISTANCE <br />RETURN AIR <br />RADIATOR <br />REFLECTED CEILING PLAN <br />ROOF DRAIN <br />REGISTER, REGULATION <br />REINFORCE <br />REQUIRED <br />REVISION <br />REQUEST FOR INFORMATION <br />RIGHT HAND, ROOF HATCH <br />RAIN LEADER <br />ROOM <br />REVERSE OSMOSIS, ROUGH OPENING <br />ROOF TOP UNIT <br />ROOFVENT <br />SOUTH <br />SANITARY <br />SCHEDULE <br />SECTION <br />SQUARE FOOT, SAFETY FACTOR <br />SHOWER <br />SHEET <br />SIMILAR <br />SLAB ON GRADE <br />SPECIFICATION(S) <br />SQUARE <br />STAINLESS STEEL <br />STANDARD <br />STORAGE <br />STRUCTURAL <br />UBSTITUTE <br />SAFETY VALVE, SHEET VINYL <br />SQUARE YARD <br />SYMBOL <br />SYSTEM <br />r TREAD <br />r & B TOP AND BOTTOM <br />rD TRENCH DRAIN <br />rECH TECHNICAL, TECHNOLOGY <br />rEMP TEMPORARY, TEMPERATURE <br />rHK THICKNESS <br />rHRU THROUGH <br />roc TOP OF CONCRETE <br />rOF TOP OF FOOTING, TOP OF FLOOR, TOP OF FRAME <br />rOS TOP OF STEEL <br />rYP TYPICAL <br />HEAT TRANSFER COEFFICIENT <br />UNDERGROUND <br />UNIT HEATER <br />UNDERWRITERS LABORATORIES <br />UNLESS NOTED OTHERWISE <br />UTILITY <br />UNIT VENTILATOR <br />SANITARY VENT, VOLT <br />VARIES, VARIATION <br />VENTILATION <br />VERTICAL <br />VOLUME <br />VERTICAL UNIT HEATER <br />SAN WASTE, WATT, WEST <br />WITH <br />WITHOUT <br />WALL COVERING, WATER CLOSET <br />WIDE FLANGE <br />WATER HEATER, WALL HUNG <br />WROUGHT IRON <br />WEIGHT <br />YD <br />NOTES: <br />1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAYBE REQUIRED. <br />2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS FOR THE 2018 EDITION OF THE UNIFORM PLUMBING CODE AS AMENDED BY THE <br />STATE OF WASHINGTON. <br />3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. <br />4. SLOPE ALL WASTE PIPING AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING WASTE PIPING AT <br />LESS THAN 2 % (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS) <br />5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH SECTION 313.6 AND 313.0 - TABLE 313.5 OF THE 2018 UNIFORM PLUMBING CODE. <br />6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY <br />AND RATING OF THE FLOOR OR WALL. <br />7. FOR EXACT ROUGH -IN LOCATIONS AND ELEVATIONS OF PLUMBING FIXTURES REFER TO ARCHITECTURAL DRAWINGS. <br />8. PROVIDE STOPS OR ANGLE VALVES AT ALL FIXTURES, <br />9. PROVIDE TRAP PRIMERS FOR ALL SELDOM USED FLOOR DRAINS, TRENCH DRAINS AND STANDPIPES. <br />10. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. <br />11. CLEAN OUTS SHALL BE INSTALLED SO THEY ARE EASILY ACCESSIBLE. <br />12. PLUMBING EQUIPMENT, VALVES AND TRAP PRIMERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS, UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, <br />REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. <br />13. WATER HAMMER ARRESTERS -PROVIDE PDI RATED WATER HAMMER ARRESTERS AT ALL FIXTURE GROUPINGS. <br />PLUMBING EQUIPMENT SCHEDULE <br />TAG <br />DESCRIPTION <br />MAKE <br />MODEL <br />SERVICE <br />COMMENT <br />HWT-1 <br />GAS FIRED CONDENSING <br />WATER HEATER <br />RHEEM <br />GHE80SU-130 <br />DOMESTIC HOT WATER <br />80GAL, 130MBH, NON-ASME <br />ET-1 <br />THERMAL EXPANSION TANK <br />AMTROL <br />ST-12 <br />DOMESTIC HOT WATER <br />4.4GAL <br />MV-1 <br />THERMOSTATIC MIXING VALVE <br />SYMMONS <br />7-400 <br />DOMESTIC HOT WATER <br />BUILDING HW SUPPLY SET TO 120' <br />HWCP-1 <br />CIRCULATING PUMP <br />BELL & GOSSETT <br />NBF 25 <br />DOMESTIC HOT WATER RECIRC <br />W/ TIMER AND AQUASTAT <br />BV-1 <br />BALANCING VALVE <br />BELL & GOSSETT <br />CIRCUIT SETTER <br />DOMESTIC HOT WATER RECIRC <br />WM-1 <br />WATER METER <br />M&E <br />PD40-1.5T <br />TENANT SPACE DOMESTIC WATER <br />W/ WIRELESS REMOTE DISPLAY <br />SUPPLY <br />PRV-1 <br />PRESSURE REDUCING VALVE <br />ZURN/WILKINS <br />500XL <br />TENANT SPACE DOMESTIC WATER <br />SUPPLY <br />RPBP-1 <br />BACKFLOW ASSEMBLY <br />ZURN/WILKINS <br />975XL2TCU <br />TENANT SPACE DOMESTIC WATER <br />1-1/2" W/ STRAINER AND AIR GAP <br />SUPPLY ISOLATION <br />RPBP-2 <br />BACKFLOW ASSEMBLY <br />ZURN/WILKINS <br />975XL2TCU <br />WASH AREA DOMESTIC WATER <br />1"W/ STRAINER AND AIR GAP <br />ISOLATION <br />WHA-1 <br />WATER HAMMER ARRESTOR <br />SIOUX CHIEF <br />653-BS <br />DOMESTIC COLD WATER SERVICE <br />UH-1 <br />GAS FIRED UNIT HEATER <br />- <br />_ <br />_ <br />75MBH, FURNISHED AND <br />INSTALLED BY OTHERS <br />Copyright©, Stirrett-Johnsen, Inc., Silverdale, Washington. License to use this design is limited to construction of its particular <br />subject. Authority to retain copies or any derivatives such as shop drawings is limited to one set for record purposes. This design was <br />produced assuming construction by Stinett Johnsen field forces and an expectation that field conditions may require adjustment <br />which would be coordinated with, or by, those field forces. <br />SCOPE OF WORK <br />TI REMODEL OF A 20,600 SO FT OFFICEIWAREHOUSE BUILDING FOR USE AS A STORAGE <br />FACILITY WITH NEW OXYGEN STORAGE ROOM, WASHDOWN AREA, AND OFFICE EXPANSION <br />WHICH INCLUDES TWO NEW RESTROOMS. THE PROJECT INCLUDES DOMESTIC WATER, <br />SANITARY W&V, AND NATURAL GAS SYSTEMS. <br />SHEET LIST <br />SHEET NUMBER <br />SHEET NAME <br />PO.00 <br />PLUMBING SPECIFICATIONS AND SCHEDULES <br />P2.OD <br />PLUMBING DEMOLITION PLAN <br />P2.00 <br />UNDERGROUND PLUMBING FLOOR PLAN <br />P2.01 <br />LEVEL 1 PLUMBING FLOOR PLAN <br />P3.00 <br />PLUMBING DETAILS <br />PLUMBING FIXTURE SCHEDULE <br />TAG DESCRIPTION MAKE/MODEL W V CW HW WSFU DFU COMMENTS <br />WC-1 WATER CLOSET KOHLER K-4306-0 - BOWL, KOHLER K-4469-0 - TANK, BEMIS 4" 2" 1/2" - 2.5 4.0 ADA COMPLIANT, FLOOR MOUNT, TANK TYPE <br />1955CT-000 - SEAT <br />UR-1 <br />URINAL <br />KOHLER K-4991-ET-0 - URINAL, SLOAN ROYAL 186-0.125 - <br />2" <br />2" <br />3/4" <br />- <br />4.0 <br />2.0 <br />MANUAL FLUSH VALVE <br />FLUSH VALVE <br />LV-1 <br />LAVATORY <br />KOHLER K-2196-4 - LAVATORY, CHICAGO 895-317ABCP - <br />2" <br />2" <br />1/2" <br />1/2" <br />1.0 <br />1.0 <br />ADA MANUAL FAUCET <br />FAUCET <br />SK-1 <br />HAND WASH SINK <br />KOHLER K-2032-0 - LAVATORY, CHICAGO 895-317ABCP <br />2" <br />2" <br />1/2" <br />1/2" <br />1.5 <br />2.0 <br />WALL HUNG <br />FAUCET <br />SK-2 <br />CLEAN ROOM SINK <br />ELKAY E12C18X21X - S.S. SINK, CHICAGO 540- <br />2" <br />2" <br />1/2" <br />1/2" <br />1.5 <br />2.0 <br />FREESTANDING, DUAL BASIN <br />LDL9E35XKABCP-FAUCET <br />SK-3 <br />BREAKROOM SINK <br />ELKAY LR25221 - S.S. SINK, MOEN 7864 - FAUCET <br />2" <br />2" <br />1/2" <br />1/2" <br />1.5 <br />2.0 <br />DROP -IN DUAL BASIN SINK, MANUAL FAUCET <br />SK-4 <br />FITTING ROOM SINK <br />ELKAY LR17201 - S.S. SINK, MOEN 7864 - FAUCET <br />2" <br />2" <br />1/2" <br />1/2" <br />1.5 <br />2.0 <br />DROP -IN SINK, MANUAL FAUCET <br />SH-1 <br />SHOWER <br />FIBERCARE PR62-36BF- SHOWER PAN, SYMMONS <br />2" <br />2" <br />1/2" <br />1/2" <br />2.0 <br />2.0 <br />ADA COMPLIANT, W/HANDSHOWER <br />262XBODY - VALVE, SYMMONS S9608-PLR-TRM-1.5 - TRIM <br />JS-1 <br />JANITOR SINK <br />MUSTEE 63MX - BASIN, MUSTEE 63.600A - SERVICE <br />3" <br />2" <br />3/4" <br />3/4" <br />3.0 <br />3.0 <br />W/ BUMPER GUARDS, HOSE, AND BRACKET <br />FAUCET <br />DF-1 <br />DRINKING FOUNTAIN <br />ELKAY LZSTLDDWSLK - DRINKING FOUNTAIN <br />2" <br />2" <br />1/2" <br />- <br />0.5 <br />0.5 <br />ADA COMPLIANT, DUAL HEIGHT W/ BOTTLE FILLER <br />ESEW-1 <br />EMERGENCY SHOWER & EYEWASH <br />GUARDIAN G1902 - COMBINATION SHOWER & EYEWASH <br />- <br />- <br />3/4" <br />3/4" <br />- <br />- <br />ETMV-1 <br />EMERGENCY THERMOSTATIC MIXING <br />GUARDIAN G6040 - THERMOSTATIC MIXING VALVE <br />- <br />- <br />1" <br />1" <br />- <br />- <br />SERVES ESEW-1 <br />VALVE <br />IB-1 <br />ICE MAKER BOX <br />SIOUX CHIEF 696-G1010MF <br />- <br />- <br />1/2" <br />- <br />0.5 <br />- <br />HB-1 <br />HOSE BIB <br />WOODFORD MODEL 24 <br />- <br />- <br />3/4" <br />- <br />2.5 <br />- <br />FD-1 <br />FLOOR DRAIN <br />SIOUX CHIEF 860-3PU <br />4" <br />2" <br />- <br />- <br />- <br />2.0 <br />4" PVC FLOOR DRAIN W/ 9" ROUND PVC STRAINER & DEBRIS BUCKET <br />FD-2 <br />FLOOR DRAIN <br />SIOUX CHIEF 860-3PU <br />2" <br />2" <br />- <br />- <br />- <br />2.0 <br />2" PVC FLOOR DRAIN W/ 9" ROUND PVC STRAINER & DEBRIS BUCKET <br />FCO-1 <br />FLOOR CLEANOUT <br />SIOUX CHIEF 843-4PNR <br />4" <br />- <br />- <br />- <br />- <br />- <br />4" PVC FLOOR CLEANOUT W/ 6-1/2" TOP <br />PIPING MATERIAL SPECIFICATIONS <br />PIPING <br />LOCATION <br />MATERIAL <br />JOINT <br />COLD WATER <br />ABOVE GROUND <br />COPPER TYPE L <br />LEAD-FREE SOLDER <br />COPPER TYPE L <br />PROPRESS MECH JOINT <br />CPVC SCH 80 <br />SOLVENT CEMENT <br />HOT WATER <br />ABOVEGROUND <br />COPPER TYPE L <br />LEAD-FREE SOLDER <br />COPPER TYPE L <br />PROPRESS MECH JOINT <br />CPVC SCH 80 <br />SOLVENT CEMENT <br />SANITARY WASTE & VENT <br />ALL <br />PVC SCH 40 DWV <br />SOLVENT CEMENT <br />INDIRECT WASTE <br />ALL <br />PVC SCH 40 DWV <br />SOLVENT CEMENT <br />TRAP PRIMER <br />ALL <br />PEX <br />MFR APPROVED <br />WATER HEATER SUPPLY <br />AIR AND EXHAUST <br />ALL <br />PVC SCH 40 DWV <br />SOLVENT CEMENT <br />NATURAL GAS <br />ALL <br />SCH 40 BLACK STEEL <br />MEGAPRESS MECH JOINT <br />PIPING INSULATION SCHEDULE <br />PIPING <br />PIPING <br />INSULATION <br />INSULATION <br />CONDUCTIVITY <br />TYPE <br />SIZE <br />TYPE <br />THICKNESS <br />RANGE <br />OVERHEAD COLD WATER <br />ALL <br />FIBERGLASS <br />1/2" <br />- <br />COLD WATER WITHIN WALLS <br />NOT REQUIRED <br />1/2"TO11/4" <br />FIBERGLASS <br />V <br />0.22-0.28 <br />HOT WATER AND RECIRC <br />11/2"TO6" <br />FIBERGLASS <br />11/2" <br />0.22-0.28 <br />NOTES: <br />1. ALL PIPING INSULATION SHALL MEET THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE. <br />2. ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN <br />ASTM SMOKE DEVELOPED RATING OF 50 OR LESS <br />3. ELASTOMERIC INSULATION WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS <br />4. PROVIDE A COVERING FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING. <br />5. PROVIDE AN INCOMPRESSIBLE INSULATED PAD WITH A MINIMUM THERMAL RESISTANCE OF R-10 UNDER ALL <br />ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE FLOOR, <br />BACKFLOW PROTECTION <br />BUILDING: <br />PROVIDENCE TENANT SPACE ISOLATED VIA REDUCED PRESSURE BACKFLOW PREVENTER. <br />OTHERS: <br />CLEANING AREA DOMESTIC WATER ISOLATED VIA REDUCED PRESSURE BACKFLOW <br />PREVENTER. <br />ALL EQUIPMENT UTILIZING WATER SHALL BE ISOLATED VIA VACUUM BREAKERS OR AIR GAPS <br />PER UPC AND AWWA REQUIREMENTS. <br />ALL INDIRECT WASTE TO BE ISOLATED PER UPC REQUIRMENTS. <br />SEISMIC BRACING <br />THE SYSTEMS SHOWN ON THIS DESIGN HAVE A COMPONENT IMPORTANCE FACTOR Ip PER BELOW <br />Ip =1.0 BY DEFAULT <br />Ip =1.5 IF SUPPORTS LIFE SAFETY, CONTAINS TOXIC OR EXPLOSIVE SUBSTANCES, IN A RISK CAT. IV STRUCTURE <br />NATURAL GAS, FUEL OIL, LPG IS ALWAYS Ip =1.5 <br />SEE ARCHITECTURAL OR STRUCTURAL DRAWINGS FOR STRUCTURE RISK CATEGORY <br />THIS TABLE ASSUMES PROJECT LOCATION IS IN THE PACIFIC NORTHWEST - SEISMIC DESIGN CAT. "D" <br />THIS TABLE IS BASED ON IBC 2018 AND ASCE 7-13 <br />SEISMIC BRACING REQUIRED ON PIPE WHEN <br />MATERIAL <br />SYSTEM <br />Ip OF 1.0 <br />Ip GREATER THAN 1.0 <br />PVC,CPVC, NHCI <br />VENT <br />4" AND LARGER <br />1-1/4" AND LARGER <br />PVC, CPVC, NHCI <br />ALL OTHERS <br />3" AND LARGER <br />1-1/4" AND LARGER <br />CU, SS <br />ALL <br />4" AND LARGER <br />1-1/4" AND LARGER <br />SEISMIC BRACING SPACING <br />MATERIAL <br />JOINT <br />TRANSVERSE <br />LONGITUDINAL <br />ON CHANGE OF DIRECTION <br />DUCTILE (CU, CS, SS) <br />ALL BUT THREADED <br />40' SPACING <br />80' SPACING <br />LONGER THAN 4' <br />DUCTILE (CU, CS, SS) <br />THREADED <br />20' SPACING <br />40' SPACING <br />LONGER THAN 4' <br />BRITTLE (PVC, CPVC, NHCI) <br />ALL <br />20' SPACING <br />40' SPACING <br />LONGER THAN 4' <br />MED GAS, NG, LPG, FO <br />ALL <br />20' SPACING <br />40' SPACING <br />LONGER THAN 4' <br />NOTES: <br />EXCEPTION -12" RULE: WHERE TOP OF PIPE IS 12" OR LESS FROM SUPPORTING STRUCTURE, SEISMIC <br />BRACING WILL NOT BE REQUIRED. <br />100 % OF PIPE RUN MUST FALL WITHIN 12" OF SUPPORTING STRUCTURE. <br />NO HUB PIPING: BRACE NO HUB PIPING ON EACH SIDE OF 90 DEGREE HORIZONTAL CHANGE IN DIRECTION. <br />PENETRATIONS: VERTICAL PENETRATION WITH V OR LESS GAP BETWEEN PIPE AND SLEEVE COUNTS AS A <br />TRANSVERSE AND LONGITUDINAL BRACE. <br />EQUIPMENT: ALL EQUIPMENT 400 LBS AND MORE REQUIRE ENGINEERED SEISMIC BRACING AND SUPPORTS <br />PER 2018 IBC 1613.1. <br />SYMBOLS <br />FLANGE <br />CONCENTRIC REDUCER <br />T <br />PRESSURE GAGE <br />SLOPE <br />DIRECTION OF SLOPE DOWN <br />4 THERMOMETER <br />] PLUG OR CAP <br />STRAINER WITH BLOWOFF VALVE <br />2 CHECK VALVE <br />-( COMBINATION PRESSURE -TEMPERATURE INSERTABLE <br />TAP <br />2 �Z PUMP (FLOW DIRECTION INDICATED) <br />GATE, BALL OR BUTTERFLY VALVE AS SPECD <br />(UNLESS OTHERWISE NOTED) <br />^�^ 2-WAY AUTOMATIC CONTROL VALVE <br />METERING BALANCING VALVE <br />RELIEF VALVE (RV) <br />APPLICABLE PROJECT CODES <br />YEAR <br />DESCRIPTION <br />2018 <br />INTERNATIONAL BUILDING CODE, CHAPTER 51-50 WAC <br />2018 <br />INTERNATIONAL MECHANICAL CODE, CHAPTER 51-52 WAC <br />2018 <br />UNIFORM PLUMBING CODE, CHAPTER 51-56 WAC <br />2018 <br />INTERNATIONAL FIRE CODE, CHAPTER 51-54A WAC <br />2018 <br />INTERNATIONAL ELECTRIC CODE WITH WA AMMENDMENTS <br />2018 <br />WASHINGTON STATE ENERGY CODE, CHAPTER 51-11C WAC <br />2009 <br />ANSI At 17.1 ACCESSIBILITY CODE <br />PERMIT SET 2022.07.07 <br />IF SHEET IS NOT 30" x 42' <br />SCALE ACCORDINGLY <br />E U <br />LU _� W <br />G <br />� Cn <br />(ll U) O <br />0 <br />_0 (D <br />-O Cz U <br />L n <br />a <br />W <br />(D <br />w E <br />_=3 <br />IL <br />Project No. 447 <br />Drawn By BTS <br />Checked By JM <br />