Laserfiche WebLink
01 RPBP-1 ISO <br />.01 N.T.S. <br />1" NG SUPPLY <br />THERMOMETER <br />ROOF <br />CONCENTRIC VENT <br />STNR WV1" <br />3" EXHAUST FLUE �` � `3"COMBUSTION AIR <br />03 E, . , , „ ..,.,,., <br />.01 N.T.S. <br />1 1/4" DHW (120° F) TO BUILDING <br />SOV <br />HOSE END FOR <br />SOV SETTING MV <br />00*4 <br />SOV STNR <br />3/4" DI <br />THERMOMETER 1 1/4"DHW (140° F) MV-1 3/4"DCW <br />3/4" DCW CHK <br />SOV <br />I <br />1 1/4" DHW (140°F) <br />SET DIAL 41 <br />BALANCING VALVE <br />SET TO 40 <br />SOV CHK BV-1 <br />HOSE END <br />PURGE VALVE <br />o BALANCING VALVE <br />SET TO 10 <br />THERMOMETER <br />SOV <br />3/4" DHWC FROM BUILDING <br />FLANGED END CONNECTIONS, <br />AOUASTAT AND TIMER SET TO SPEED #3 <br />PROVIDE SEISMIC BRACING @ UPPER <br />1/3 & LOWER 1/3 OF WATER HEATER PROVIDE DIELECTRIC <br />SOV <br />VERTICAL DIMENSION, AT LOWER 1/3 A <br />DISTANCE OF NOT LESS THAT 4" NIPPLE AT ALL HWT <br />PROVIDE TEMP & PRESSURE <br />RELIEF VALVE, DISCHARGE <br />CHK SOV <br />CONNECTIONS <br />SHALL BE MAINTAINED FROM THE <br />CONTROLS WITH THE BRACING <br />I INDIRECTLY TO DRAINAGE SYSTEM <br />1 1/4" DCW <br />I <br />SOV <br />TP�I'PESIZE TO MATCH ET <br />1"DCW <br />1"DCWE <br />CONNECTION SIZE <br />PROVIDE INCOMPRESSIBLE, INSULATED <br />I <br />SURFACE WITHAMINIMUNTHERMAL o <br />o WATER HEATER DRAIN <br />IF ET IS OVER 11.25 GALLONS,INSTALL <br />PROVIDE ET WITH SEISMIC MOUNT& <br />RESISTANCE IN R-10 FOR ELECTRIC WATER <br />HEATERS INSTALLED IN UNCONDITIONED <br />I <br />— — — — — — — — — — — — — — — — J <br />PROVIDE RELIEF VALVE & ROUTE <br />WITH CONNCTION ON TOP <br />— — — — — — — <br />DISCHARGE INDIRECTLY TO <br />ONLY ON NON -FLOOR MOUNTED ET's <br />( ) <br />SPACES OR ON CONCRETE FLOORS PER WSEC � <br />CONDENSATE DRAIN <br />DRAINAGE SYSTEM <br />PROVIDE WATERTIGHT DRAINAGE PAN <br />CONSTRUCTED OF CORROSION RESISTANT <br />MATERIALS WITH NOT LESS THAN A 3/4" <br />DRAIN & NOT LESS THAN 1 1/2" IN DEPTH <br />02 DOMESTIC GAS HOT WATER TANK DIAGRAM <br />01 N.T.S. <br />Copyright @, Stirrett-Johnsen, Inc., Silverdale, Washington. License to use this design is limited to construction of its particular <br />subject. Authority to retain copies or any derivatives such as shop drawings is limited to one set for record purposes. This design was <br />produced assuming construction by Stinett Johnsen field forces and an expectation that field conditions may require adjustment <br />which would be coordinated with, or by, those field forces. <br />PERMIT SET 2022.07.07 <br />IF SHEET IS NOT W' x 42' <br />SCALE ACCORDINGLY <br />wo� <br />UJ _:3 N <br />(Z <br />� ++ <br />U 0 <br />_0 C <br />"O 2 <br />L <br />w <br />Project No. 447 <br />Drawn By BTS <br />Checked By JM <br />P3.00.00 <br />