Laserfiche WebLink
3z/06.01 <br />7 <br />-� SHUTLER <br />��- CONSULTING <br />ENGINEERS, Inc. <br />12503 Bel -Red Road, Suite 100 <br />Bellevue, Washington 98005 <br />(425) 450-4075 FAX (425) 450-4076 <br />STRUCTURAL CALCULATIONS FOR: <br />HOT CELL T.I. -- <br />TERRAPOWER <br />3315 SEAWAY BLVD. <br />EVERETT, WASHINGTON <br />PROPOSED BY: <br />TERRAPO WER <br />11�R�?) U E <br />JUL 15 2021 <br />CITY OF EVERETT <br />Permit Services <br />DESIGN CRITERIA: <br />CODE.................................. <br />ROOF LIVE LOAD ................. <br />PLATFORM LIVE LOAD......... <br />WIND LOAD ......................... <br />SEISMIC ZONE ..................... <br />JOB TerraPower <br />SHEET NO. COVER OF <br />CALCULATED BY jch DATE 5/19/2021 <br />CHECKED BY <br />JOB NUMBER 19-01.13H <br />DATE <br />INTERNATIONAL BUILDING CODE, 2018 EDITION <br />25 PSF SNOW LOAD, Is=1.0 <br />30 PSF <br />100 MPH ZONE, EXPOSURE "B" <br />SITE CLASS'D', Sds=0.925, Sd1=0.594, Ie=1.0 <br />DESIGN CATEGORY'D', R=6.5 <br />EQUIPMENT ON PLATFORM.... ap=2.5, Rp=6.0, Ip=1.0 <br />EQUIPMENT ON SLAB............ ap-2.5, Rp=2.5, Ip=1.0 <br />ALLOWABLE SOIL BEARING IS 3,000 PSF PER ORIGINAL STRUCTURAL DRAWINGS <br />DATED JULY 7, 2016. <br />