MECHANICAL ABBREVIATIONS <br />A AMPS <br />AC AIR CONDITIONING <br />ACH AIR CHANGES PER HOUR <br />ACT ACOUSTICAL CEILING TILE <br />AD ACCESS DOOR <br />ADD'L ADDITIONAL <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AHU AIR HANDLING UNIT <br />ALUM ALUMINUM <br />AMP/AMPS AMPERAGE <br />AP ACCESS PANEL <br />ARCH ARCHITECT <br />BC BEADED COLLAR <br />BDD BACKDRAFT DAMPER <br />BF BELOW FLOOR <br />BHP BRAKE HORSEPOWER <br />BLDG BUILDING <br />BOD BOTTOM OF DUCT <br />BOP BOTTOM OF PIPE <br />BOT BOTTOM <br />BS BIRD SCREEN / BLACK STEEL <br />BTU BRITISH THERMAL UNIT <br />BTUH BRITISH THERMAL UNITS PER HOUR <br />CAP CAPACITY <br />CBD CALIBRATED BALANCING DAMPER <br />CC CONTROLS CONTRACTOR <br />CD CEILING DIFFUSER/CONDENSATE DRAIN <br />CDWR CONDENSER WATER RETURN <br />CDWS CONDENSER WATER SUPPLY <br />CFM CUBIC FEET PER MINUTE <br />CHAR CHILLED WATER RETURN <br />CHWS CHILLED WATER SUPPLY <br />CLG CEILING <br />COL COLUMN <br />CONC CONCRETE <br />COND CONDENSATE <br />CONN CONNECT/CONNECTED/CONNECTION <br />CONT CONTINUOUS/CONTINUATION <br />CONTR CONTRACTOR <br />COORD COORDINATE <br />COP COEFFICIENT OF PERFORMANCE <br />CT COOLING TOWER <br />CU CUBIC/CONDENSER UNIT <br />CW DOMESTIC COLD WATER/CONDENSER WATER <br />DIE DUCTBOARD/DRY BULB/DECIBEL <br />DDC DIRECT DIGITAL CONTROL <br />DEFL DEFLECTION <br />DEG DEGREE/DEGREES <br />DIA DIAMETER <br />DMPR DAMPER <br />DN DOWN <br />DOAS DEDICATED OUTSIDE AIR SYSTEM <br />DWG DRAWING <br />EXH EXHAUST <br />EA EACH/EXHAUST AIR <br />EAT ENTERING AIR TEMPERATURE <br />EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR <br />EER ENERGY EFFICIENT RATING <br />EF EXHAUST FAN <br />EFF EFFICIENCY <br />EL ELEVATION <br />ELEC/ELECT ELECTRICAL/ELECTRIC <br />EMCS ENERGY MANAGEMENT CONTROL SYSTEM <br />ENT ENTERING <br />EQUIP EQUIPMENT <br />ESP EXTERNAL STATIC PRESSURE <br />EWT ENTERING WATER TEMPERATURE <br />EXIST/(E) EXISTING <br />EXH EXHAUST <br />F FAHRENHEIT <br />FAC FIRE ALARM CONTRACTOR <br />FD FIRE DAMPER <br />FDC FIRE DEPARTMENT CONNECTION <br />FF FINISHED FLOOR <br />FTC FURNISHED AND INSTALLED BY CONTRACTOR <br />FIO FURNISHED AND INSTALLED BY OWNER <br />FLA FULL LOAD AMPS <br />FLEX FLEXIBLE <br />FLR FLOOR <br />FOB FLAT ON BOTTOM <br />FOIC FURNISHED BY OTHERS, <br />INSTALLED BY CONTRACTOR <br />FOS FLAT ON SIDE <br />POT FLAT ON TOP <br />FP FIRE PROTECTION <br />FPM FEET PER MINUTE <br />FSD FIRE/SMOKE DAMPER <br />FT FOOT/FEET <br />FUT FUTURE <br />TV FACE VELOCITY <br />G GRILLE <br />GA GAUGE/GALLON <br />GALV GALVANIZED <br />GC GENERAL CONTRACTOR <br />GPM GALLONS PER MINUTE <br />GRID GRILLE/REGISTER/DIFFUSER <br />GWB GYPSUM WALL BOARD <br />HD HEAD <br />HORIZ HORIZONTAL <br />HP HORSEPOWER <br />HR HOUR <br />HSPF HEATING SEASONAL PERFORMANCE FACTOR <br />HT HEIGHT <br />HWTG HIGH WALL TRANSFER GRILLE <br />HWR HOT WATER RETURN <br />HWS HOT WATER SUPPLY <br />HX HEAT EXCHANGER <br />HZ HERTZ <br />IBC INTERNATIONAL BUILDING CODE <br />CW INDUSTRIAL COLD WATER <br />ID INSIDE DIAMETER/DIMENSION <br />IE INVERT ELEVATION <br />IEER INTEGRATED ENERGY EFFICIENCY RATIO <br />IMC INTERNATIONAL MECHANICAL CODE <br />IN INCHES <br />IN WG INCHES WATER GAUGE <br />IPLV INTEGRATED PART LOAD VALUE <br />KW KILOWATTS <br />LAT LEAVING AIR TEMPERATURE <br />LB/LBS POUND/POUNDS <br />LF/LIN FT LINEAL FOOT/FEET <br />LPG LIQUID PROPANE GAS <br />LPS LOW PRESSURE STEAM <br />LVG LEAVING <br />LWA SOUND POWER RATING LEVEL (IN DB) <br />LNG LOW WALL GRILLE <br />LWT LEAVING WATER TEMPERATURE <br />MAX MAXIMUM <br />MAU MAKE UP AIR UNIT <br />MBH 1000 BRITISH THERMAL UNITS/HOUR <br />MCA MINIMUM CIRCUIT AMPACITY <br />MD MOTORIZED DAMPER <br />MFR MANUFACTURER <br />MISC MISCELLANEOUS <br />MIN MINIMUM/MINUTE <br />MPS MEDIUM PRESSURE STEAM <br />MT MOUNT <br />MTD MOUNTED <br />MUW MAKE-UP WATER <br />NA NOT APPLICABLE <br />NO NORMALLY CLOSED/NOISE CRITERIA <br />NG/NGAS NATURAL GAS <br />NIC NOT IN CONTRACT <br />NO NORMALLY OPEN/NUMBER <br />NPW NON -POTABLE WATER <br />N-R NON-RESIDENTIAL <br />OA/OSA OUTSIDE AIR <br />OBD OPPOSED BLADE DAMPER <br />OD OUTSIDE DIAMETER/DIMENSION <br />PCF POUNDS PER CUBIC FOOT <br />PD PRESSURE DROP <br />PH PHASE <br />POC POINT OF CONNECTION <br />P/PRESS PRESSURE <br />PSI POUNDS PER SQUARE INCH <br />PSIG POUNDS PER SQUARE INCH GAUGE <br />QTY QUANTITY <br />R/(R) RETURN GRILLE/RELOCATED/RETURN <br />RA RETURN AIR <br />RD/RND ROUND <br />REF REFERENCE <br />RED REQUIRED <br />RESID RESIDENTIAL <br />RF RELIEF <br />RG REFRIGERANT DISCHARGE GAS <br />RL REFRIGERANT LIQUID <br />RPM REVOLUTIONS PER MINUTE <br />RS REFRIGERANT SUCTION <br />S SUPPLY <br />SA SUPPLY AIR <br />SAT SATURATION/SUPPLY AIR TEMPERATURE <br />SD SMOKE DETECTOR <br />S/D SLIP & DRIVE CONNECTION <br />S-C SEATTLE --- CODE <br />SEER SEASONAL ENERGY EFFICIENCY RATING <br />SENS SENSIBLE <br />SL SOUND LINED <br />SM SHEETMETAL <br />SPEC SPECIFICATION <br />SO SCREENED OPENING <br />SOO SLAB ON GRADE <br />SP STATIC PRESSURE <br />SF SQUARE FEET <br />SS STAINLESS STEEL <br />STRUC STRUCTURAL <br />TA TRANSFER AIR <br />TEMP TEMPERATURE/TEMPORARY <br />TBD TO BE DETERMINED <br />TOD TOP OF DUCT <br />TOS TOP OF STEEL/TOP OF SLAB <br />TOT TOTAL <br />TSP TOTAL STATIC PRESSURE <br />TSTAT THERMOSTAT <br />TYP TYPICAL <br />UH UNIT HEATER <br />UNO UNLESS NOTED OTHERWISE <br />V VOLT <br />VA VENTILATION AIR <br />VD VOLUME DAMPER <br />VEL VELOCITY <br />VERT VERTICAL <br />VFD VARIABLE FREQUENCY DRIVE <br />VOL VOLUME <br />W WRAPPED DUCT <br />WE WET BULB <br />WG WATER GAUGE <br />W/ WITH <br />W/0 WITHOUT <br />W/SF WATTS PER SQUARE FOOT <br />WSEC WASHINGTON STATE ENERGY CODE <br />MECHANICAL LEGEND <br />10"X10" RECT SUPPLY AIR DUCT <br />10"X® UP/TOWARD <br />10"Xio"ID, RECT SUPPLY AIR DUCT <br />10"X " DN/AWAY <br />10"X10" RECT RETURN DUCT <br />10"X® UP/TOWARD <br />10"Xlo" RECT RETURN DUCT <br />1 LLE] DN/AWAY <br />10"X10" RECT EXHAUST <br />10"Xio ® UP/TOWARD <br />10"Xff' RECT EXHAUST <br />10"X10"7 DN/AWAY <br />10"0 vim, <br />10"L (, ROUND DUCT - UP/TOWARD <br />1° L1 ROUND DUCT - DN/ AWAY <br />12"X10"q FLATOVAL DUCT - UP/ TOWARD <br />12"X100 ii FLATOVAL DUCT - DN/ AWAY <br />10"4 o DUCT OVERLAP <br />10"4 <br />BOOT TAP <br />100 <br />10"0 45' TAP <br />10 0 10 VOLUME DAMPER <br />ss , , <br />10110 CALIBRATED BALANCING DAMPER <br />RISE(R) & DROP(D) <br />TRANSITION <br />TURNING VANES/SPLITTERS <br />DUCT MOUNTED SMOKE DETECTOR <br />BACK DRAFT DAMPER <br />�rvwv� FLEXIBLE DUCT <br />AIR FLOW (DRAWN AIR) <br />�> AIR FLOW (FORCED AIR) <br />COMBINATION FSD <br />FIRE DAMPER <br />SMOKE DAMPER <br />MOTOR OPERATED DAMPER <br />o ACCESS DOORS <br />SOUND TRAP <br />FLEX CONNECTION <br />ri 7x __j6_"o_D_s_Lj ACOUSTICALLY LINED DUCT <br />OD = OUTSIDE DIMENSIONS <br />SL = SOUND LINING (THICKNESS) <br />�y FABRIC DUCT <br />® CLEARANCE <br />® SUPPLY AIR DIFFUSER <br />(WITH CORE BLANKOFF/ROTATE) <br />® CEILING EXHAUST AIR GRILLE <br />CEILING RETURN OR TRANSFER <br />AIR GRILLE <br />SLOTTED DIFFUSER (PLAN VIEW) <br />Qx REVISION CLOUD & TRIANGLE <br />##"0 ROUND DUCT SYMBOL <br />##X##O FLATOVAL DUCT SYMBOL <br />#° DEGREES SYMBOL <br />9 POINT OF CONNECTION <br />CD1-100 GRD TAG IDENTIFIER = TYPE-CFM <br />8"0 SIZE <br />OT TSSTAT/TEMP SENSOR ®o CARBON DIOXIDE SENSOR <br />OH HUMIDITY SENSOR CO CARBON MONOXIDE SENSOR <br />SD SMOKE DETECTOR OS SENSOR <br />SP STATIC PRESSURE SENSOR ®° NITROGEN DIOXIDE SENSOR <br />OO OCCUPANCY SENSOR <br />EXISTING DUCTWORK <br />DEMO DUCTWORK <br />�I WALL -MOUNTED GRILLE <br />t o PIPE ELBOW UP <br />PIPE ELBOW DN <br />t t DIRECTION OF FLOW <br />DIRECTION OF SLOPE DOWN <br />�] PLUG OR CAP <br />PRESS REDUCING ASSEMBLY <br />SOLENOID VALVE <br />PUMP <br />2-CHWS/CHWRi CHILLED WATER SUPPLY/RETURN <br />?RL/iRS- REFRIGERANT LIQUID/SUCTION <br />NG NATURAL GAS <br />LPG LIQUID PROPANE GAS <br />i--CDWS/CDWR-S CONDENSER WATER SUPPLY/RETURN <br />2---HWS/HWR--S HEATING WATER SUPPLY/RETURN <br />Z­ COND --s CONDENSATE <br />zFOVFUEL OIL VENT <br />Z---FOS/FORS FUEL OIL SUPPLY/RETURN <br />?RDGREFRIGERANT DISCHARGE GAS <br />MECHANICAL GENERAL NOTES <br />1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2018 IBC, 2018 WSEC, 2018 IMC, & <br />SIMILAR YEAR WAC 296-104 BOILER RULES. <br />2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNO. <br />3. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER <br />TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE, <br />4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK, <br />5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR <br />WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING, <br />6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO. <br />7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNO: LOW PRESSURE DUCTWORK (DOWNSTREAM OF <br />VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION CLASS WITH SEAL CLASS C. MEDIUM <br />PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION CLASS WITH SEAL CLASS C <br />(UNO IN SCHEDULES AT 3 WITH SEAL CLASS B, >4" WITH SEAL CLASS A). DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET <br />6 CONSTRUCTION CLASS WITH SEAL CLASS A. OUTDOOR INSTALLED SUPPLY & RETURN DUCTS TO HAVE SEAL CLASS A. <br />8. ALL CEILING DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE. <br />9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING @ 1", UNO) <br />10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREETS, LOADING DOCK, NEIGHBORING LOT <br />LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25' ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET. <br />11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.5.1 & C403.5.5: <br />-0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING. <br />-CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. <br />-INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. <br />12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED CLASS 1 LOW LEAK (<4 CFM/SF @ 1-WG) <br />DAMPERS OR GRAVITY PER EXCEPTIONS IN C403.7.8) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, <br />UNO FOR MOKE CONTROL SYSTEM OPERATION <br />13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, DEADBAND <br />SETTING OF AT LEAST 5T (10°F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS AND SETBACK TEMPERATURES WITH OPTIMAL <br />START CONTROL. CONTROL SYSTEM SHALL INCLUD�lA MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & <br />WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. <br />14. WHERE REQUIRED BY C408, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS <br />OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE <br />BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC <br />CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING <br />REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE <br />FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. <br />15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY <br />OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER <br />TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. <br />16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR <br />CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. <br />17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE, AT 1-1/2 HR RATING <br />UNO. <br />18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN ILL APPROVED FIRE CAULKING. ALL MATERIALS EXPOSED <br />WITHIN PLENUMS SHALL BE NON-COMBUSTIBLE OR SHALL BE ILL LISTED AND LABELED FOR INSTALLATION IN PLENUMS OR AS HAVING A FLAME <br />SPREAD INDEX < 25 AND A SMOKE -DEVELOPED INDEX OF < 50. <br />19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED IN THE RETURN AIR, PER MECH CODE, SUCH AS HVAC EQUIPMENT <br />DELIVERING (NOT EXHAUST) >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY <br />>2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, NOT IN SYSTEMS SERVING SINGLE <br />ROOMS/SPACES. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL <br />CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. <br />20. ARCHITECTURAL ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY GC AT ALL CONCEALED EQUIPMENT AND DEVICE LOCATIONS, UNLESS <br />NOTED OTHERWISE. <br />21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR <br />EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. <br />22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS AND PRESSURE/TEMPERATURE/HUMIDITY CONTROLLED ROOMS, THE FOLLOWING <br />SHALL OCCUR: <br />-USE SECTION 909.5 OF THE 2018 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT <br />CONSTRUCTION. <br />-ALL VERTICAL JOINTS, CORNERS AND WALL TRACKS (TOP AND BOTTOM) SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF <br />THE JOINT (BY GC) <br />-ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. <br />-ALL DOORSRSHAALL BE PROVIDEEDSWITH TIIGHT(DFITCTINGRGASKEETSUANDPTHRE�HOLDSSWEEPS AND OPEONNAGAINSTITHE DIRECTION OF PRESSURE. <br />-IN ADDITION TO ABOVE, ROOM ENVELOPE TO HAVE VAPOR BARRIER FOR HUMIDITY CONTROLLED ROOMS <br />-ROOM ENVELOPE TO BE INSULATED (R-11 MIN) IF TEMPERATURE DIFFERENCE EXCEEDS 10-F TO ADJACENT AREAS <br />23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. <br />24. MAXIMUM STAND(ARD LENGTH OF FLEXIBLE DUCT SHALL)) BE PER BUILDING STANDARDS OR 12' MAX; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE <br />TOTAL REFER TTO IINSTTALLATIONDDEETAILOSTFORNNECTOR'SUPPORY REQUIREIS MENTS. FLEXIBDUCT 0 IS LE DEUCTDBY 1 FLAME SPREAD LSIZE RATINGSHALLDBEDO 25 ANDCEED SMOKES <br />DEVELOPED RATING SHALL BE < 50. USE THERMAFLEX MODEL G-KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. <br />25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR <br />TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL <br />CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE <br />DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. <br />26. THE PROJECT TEAM IS COLLECTIVELY RESPONSIBLE FOR COMPLIANCE WITH [C412][APPENDIX E], "RENEWABLE ENERGY SYSTEMS." AS WELL AS <br />C406 " EFFICIENCY PACKAGES' AS APPLICABLE TO THE PROJECT AND AS COORDINATED DURING DESIGN WITH ENTIRE DESIGN/CONSTRUCTION <br />TEAM. <br />DRAWING INDEX <br />SHEET N0. <br />SHEET TITLE <br />CURRENT <br />REVISION <br />MO.00 <br />COVER SHEET - HVAC <br />MO.01 <br />CONSTRUCTION STANDARDS - HVAC <br />MO.02 <br />CONSTRUCTION STANDARDS - HVAC <br />M2.R1 <br />PARTIAL ROOF PLANS & SCHEDULE - HVAC <br />APN NUMBER <br />28051800404800 <br />LEGAL DESCRIPTION <br />SEC 18 TWP 28 RGE 05LOT 8A EVERETT MALL PLAZA - PHASE III ESP REC'D V1 MISC <br />MAPS PG 22-23 AF NO 8412195037 BEING PTN NW1/4 SE1/4 <br />WkeS 4 y <br />„ oy <br />VICINITY MAP <br />NO SCALE <br />oy <br />SITE MAP <br />NO SCALE <br />IYUYNI�l�b9�l <br />1) <br />Hermanson <br />Building Today, Defining Tomorrow <br />Herman- Company LLP <br />1221 2nd Avenue North <br />Kent, Washington 98032 <br />Tel: (206) 575-9700 <br />Fax:(206) 575-9800 <br />-hermanson.com <br />Contractor Reg /: HERMACLO05BJ <br />RTU <br />REPLACE <br />EVERETT MALL PLAZA, SUITE C <br />1321 SE EVERETT MALL WAY <br />EVERETT, WA 98208 <br />ODOR N <br />J�O DF WAsyr FH <br />q¢ ~ Pt36149 <br />roNAL 6 <br />DECEMBER 3, 2022 <br />ISSUE FOR PERMIT <br />Revisions <br />_ 12/02/22 JMH ISSUE FOR PERMIT <br />No. Date By Description <br />Design Team <br />Design JMH <br />Drawn FVP <br />Checked DTN <br />Pre -Construction Number 14-22-22759 <br />Construction Number <br />Issue Date 12/02/22 <br />COVER <br />SHEET <br />- HVAC <br />J'I_L,llllfJ <br />