My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 SE EVERETT MALL WAY BASE FILE 2024-02-26
>
Address Records
>
SE EVERETT MALL WAY
>
1321
>
BASE FILE
>
1321 SE EVERETT MALL WAY BASE FILE 2024-02-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 9:58:02 AM
Creation date
5/12/2023 7:27:15 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DESCRIPTION: (E) GLB check under RTU-1 <br />CODE REFERENCES <br />Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 <br />Load Combination Set: IBC 2018 <br />Material Properties <br />Analysis Method : Allowable Stress Design <br />Fb + <br />2400 psi <br />E: Modulus of Elasticity <br />Load Combination IBC 2018 <br />Fb - <br />1850 psi <br />Ebend- xx <br />1800ksi <br />Fc - Prll <br />1650 psi <br />Eminbend - xx <br />950ksi <br />Wood Species DF/DF <br />Fc - Perp <br />650 psi <br />Ebend- yy <br />1600ksi <br />Wood Grade 24F-V4 <br />Fv <br />265 psi <br />Eminbend - yy <br />850ksi <br />Ft <br />1100 psi <br />Density <br />31.21 pcf <br />Beam Bracing : Beam is Fully Braced against lateral -torsional buckling <br />D(0.81) W(0.41) E(Q.208) <br />Span = 19.0 ft <br />ied Loads <br />e loads entered. Load Factors will be applied for calculations. <br />Beam self weight NOT int4elly calcula and added✓ �T <br />Uniform Load: D = 0.450, S = 0.750, Tributary Width = 1.0 ft <br />Point Load : D = 0.810, W = 0.410, E = 0.2080 k @ 10.0 ft, (from RTU-1) <br />Maximum Bending Stress Ratio = <br />0.731: 1 Maximum Shear Stress Ratio <br />= <br />0.408 : 1 <br />Section used for this span <br />6.75x18 <br />Section used for this span <br />6.75x18 <br />fb: Actual = <br />1,904.72psi <br />fv: Actual <br />= <br />124.43 psi <br />Pb = <br />2,604.27psi <br />F'v <br />= <br />304.75 psi <br />Load Combination <br />+D+S <br />Load Combination <br />+D+S <br />Location of maximum on span = <br />9.847ft <br />Location of maximum on span <br />= <br />17.544ft <br />Span #where maximum occurs = <br />Span # 1 <br />Span # where maximum occurs <br />= <br />Span # 1 <br />Maximum Deflection <br />i Max Downward Transient Deflection <br />0.375 in Ratio = 608 >=360 Span: 1 S Only <br />Max Upward Transient Deflection <br />0 in Ratio = <br />0 <360 n/a <br />j <br />Max Downward Total Deflection <br />0.633 in Ratio = 360 -180 Span: 1 : +D+S <br />Max Upward Total Deflection <br />0 in Ratio = <br />0 <180 n/a <br />......... __._............... ._........ <br />Maximum Forces & Stresses for Load <br />Combinations <br />Load Combination ax Stress Ratios <br />omen Values <br />ear a ues <br />Segment Length Span # M V <br />CD <br />CM Ct CLx Cy <br />Cfu C i Cr M fb <br />F'b <br />V fv <br />F'v <br />D Only <br />0.0 <br />0.00 0.0 <br />0.0 <br />Length = 19.0 ft 1 0.389 0.209 <br />0.90 <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 24.08 792.9 <br />2,038.1 <br />4.05 50.0 <br />238.5 <br />+D+Lr <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 <br />0.0 <br />0.00 0.0 <br />0.0 <br />Length = 19.0 ft 1 0.280 0.151 <br />1.25 <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 24.08 792.9 <br />2,830.7 <br />4.05 50.0 <br />331.3 <br />+D+S <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 <br />0.0 <br />0.00 0.0 <br />0.0 <br />Length = 19.0 ft 1 0.731 0.408 <br />1.15 <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 57.86 1,904.7 <br />2,604.3 <br />10.08 124.4 <br />304.8 <br />+D+0.750Lr <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 <br />0.0 <br />0.00 0.0 <br />0.0 <br />Length = 19.0 ft 1 0.280 0.151 <br />1.25 <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 24.08 792.9 <br />2,830.7 <br />4.05 50.0 <br />331.3 <br />+D+0.750S <br />1.00 1.00 1.00 0.944 <br />1.00 1.00 1.00 <br />0.0 <br />0.00 0.0 <br />0.0 <br />0 <br />