Laserfiche WebLink
A1 <br /> A&RSOLAR <br /> 3211 Martin Luther King Jr Way S. <br /> Seattle,WA 98144(206)707-9937 <br /> PV Electrical Calculations <br /> Watts Output AC 4 of Total AC Comb. EGC <br /> Inverter Specs OCPD Array Specs (Adjusted for Temperature <br /> (W) Voltage Inverters out.(A) OCPD AC <br /> Solar Edge SE6000H 6000 25.00 240 1 40 1 nverter Solar Edge SE6000H ****N/A**** ****N/A**** <br /> ****N/A**** 0 0.00 0 0 0 25.0 35 410 Mppt Input 1 2 3 1 2 3 1 2 3 THIS DRAWING CONSTITUTES THE <br /> CONFIDENTIAL INFORMATION OF A&R SOLAR <br /> ****N/A**** 0 0.00 0 0 0 Amperage (Imp) 9.59 0.00 0.00 0.00 0.00 0,00 0,00 0,00 0.00 ANDIRANYRIGHTINTS RECEPTOR. ORLICENSETOUSSESSION DOES ET <br /> CONFER ANY RIGHT IN OR LICENSE TO USE IT <br /> OR THE INFORMATION DISCLOSED HEREIN <br /> Watts EGC NOR ANY RIGHT TO REPRODUCE THIS <br /> Module Specs at IMP Vmp Voc Isc Temp. Coef V(oc) DC Voltage (Vmp) 380,0 0,0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 DRAWING OR ANY PART HEREIN WITHOUT <br /> THE WRITTEN CONSENT OF A&R SOLAR. <br /> REC 405w Alpha BoB 405 9.56 42.4 48.9 10.14 -0.24 410 Max Voltage(DC) 480.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 <br /> Temp. Adjusted 37.0 52.7-77 Max Amps (DC) 15.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 <br /> Optimizer? 5440 SolarEdge Optimizer Max current output: 15A, Max Voltage: 480V Max Array Power(STC): 7.29 kW DC <br /> Equipment Solar Edge SE6000H ****N/A**** ****N/A**** <br /> Max Continuous AC Power: 6kW AC L <br /> Mppt Input 1 1 2 1 3 1 1 2 1 3 1 1 2 1 3 Q) U <br /> Module REC 405w Alpha BOB ****SELECT**** ****SELECT**** L n �Lf) No <br /> # Modules per String 9 0 0 0 0 0 0 0 0 Interconnection Calcs Site Conditions � 00 <br /> #Strings 2 0 0 0 0 0 0 0 0 Main Breaker 200 ASHRAESite: Seattle �� �_ C L Q <br /> # of Mods per group 18 0 0 0 0 0 0 0 0 Bus Bar 200 Low Temp(°F) 19 � b E <br /> # of Mods/inverter 18 0 0 Max PV OCD Allowed 40 High 2%Temp (°F) 84 W - 0.) <br /> Ln <br /> # of Inverters 1 0 O PV OCPD Device Used 40 High 0.4%Temp (°F) 91 .--1 p L- <br /> Total # of Modules 18 Tap or Breaker? Tap 'Q N W <br /> � L � <br /> a <br /> Distance Wire (QTY) Phase Neutral Neutral EGC Conduit Min. 90°C Temp Fill Derated 75°C Current Operating Voltage <br /> Ref. Conductor Description ft AL CU Gauge Conductors AWG Ty Wire Type <br /> �_ L� (QTY) (AWG) Type Conduit Rating Correct. Derate Ampacity Rating 125% Voltage Drop <br /> A String to Jbox 50 Cu #10 2 N/A N/A #6 Pv Wire 600V AIR N/A 40 1 100% 40.00 35 18.8 380 0.31% <br /> B Jbox to Inverter 50 Cu #10 4 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 18.8 380 0.31% <br /> C I nverter to Discon nect 10 Cu #8 2 #8 1 #10 THWN-2 EMT 0.75" 55 1 100% 55.00 50 31.3 240 0.16% REVISIONS <br /> D Disco. to Interconnect 10 Cu #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 65 31.3 240 0.10% Rev. #: Date: <br /> E <br /> F <br /> G <br /> H Designed by: Wes K. <br /> Total Voltage Drop: 0.89% Project Manager: <br /> Arthur Eith <br /> (612) 298-1795 <br /> Current Date:Sep 22, 2022 <br /> E2 Electrical <br /> Calculations <br />