My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10121 EVERGREEN WAY KID STRONG 2023-05-19
>
Address Records
>
EVERGREEN WAY
>
10121
>
KID STRONG
>
10121 EVERGREEN WAY KID STRONG 2023-05-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2023 10:26:20 AM
Creation date
5/19/2023 10:25:34 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10121
Tenant Name
KID STRONG
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor and Electrical Requirements List, pg 1 of 10 <br /> 2018 WSEC Requirements for Commercial Buil. •s including Group R2,R3&R4 over 3 stories&all R1-- . inistered by©2023 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at corn.techsupport©waenergycodes.com <br /> Project: <br /> Kidstrong-2018 WSEC <br /> 10121 Evergreen Way <br /> Ste 15 <br /> Everett,WA 98204 <br /> Date:2023-01-06 <br /> Applies Code Section Component Compliance Information Required In Permit Location in Building Department <br /> Documentation Documents Notes <br /> LIGHTING SCOPE <br /> C 103.1 £ ;rtttrc::ti,r For a siacil core or meant space trust .nary <br /> so?.;arnas:nN-General i7 a ;paned,indicate if there is tics is lttnra <br /> SC011.0.m . €ted litc project. <br /> YES C103.1 Construction For an alteration project,indicate if there is new lighting A-3 <br /> documents-General no lighting scope included in the project. <br /> LIGHTING CONTROLS <br /> YES C405.2 Lighting controls, -For all lighting fixtures,indicate lighting sensors <br /> general control method on plans for spaces and <br /> lighting zone(s)served,or exception taken <br /> C405.2, I.:endun€re level Indicate on plane all fixtures provided with <br /> Option 2 lighting o€trok I,I _:C`in lieu of C2405,2 lighting controls; <br /> (LLLC) provide-description of control capabilities and <br /> performance;:parn eters <br /> (3405,2.5, Ineltt.ine in dwelling Indicate method of,automatic control al.all <br /> heat 3 units pth miter . installed it.r.inaiaes in dwelling units in <br /> C° 0' =.1.1 hotel and all other buildines other than multifamily(occupancy <br /> t o 5.2.3.I than multifamily) or light're ucti n crinth'ils) <br /> a C-t D5.2.5„ Lighting in sleepit:.c indicate method of automatic off control of <br /> Item 2 units all installed luminaires in sieepitp units <br /> (vacar€c1-or key-card enn moli:also refer to <br /> Receptacles <br /> YES C405.2.3 Manual controls Indicate on plans the method of manual <br /> C405.2.3.1 lighting control,location of manual control <br /> C405.2.5 device and the area or specific application it <br /> serves <br /> YES C405.2.3.I Manual interior light Indicate on plans which method of manual A-3 <br /> C405.2.1.1 reduction controls 50%lighting load reduction is provided,or <br /> C405.2.4 indicate applicable exception <br /> YES C405.2.1 Method of automatic Indicate on plans the method of automatic A-3 <br /> C405.2.2.1 shut-off control shut-off control during unoccupied periods <br /> C405.2.1, (occupancy sensor,time switch or digital <br /> Exception 3 timer switch)for all lighting zones <br /> YES C405.2.I Occupant sensor Indicate on plans all luminaires that are a-3 <br /> controls controlled by occupant sensor controls; <br /> indicate controls are configured to turn <br /> luminaires 100%off when the space is <br /> unoccupied <br /> NA C405.2.I Occupant sensor Indicate if occupant sensor controls are <br /> C405.2.1.1 controls configured to be manual on or automatic on to <br /> not more than 50%power;indicate spaces <br /> eligible for exception that allows automatic on <br /> to 100%power <br /> Page 1/10".. <br />
The URL can be used to link to this page
Your browser does not support the video tag.