Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 1 of 10 <br /> 2018 WSEC Requirements for Commercial Buil. •s including Group R2,R3&R4 over 3 stories&all R1-- . inistered by©2023 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at corn.techsupport©waenergycodes.com <br /> Project: <br /> Kidstrong-2018 WSEC <br /> 10121 Evergreen Way <br /> Ste 15 <br /> Everett,WA 98204 <br /> Date:2023-01-06 <br /> Applies Code Section Component Compliance Information Required In Permit Location in Building Department <br /> Documentation Documents Notes <br /> LIGHTING SCOPE <br /> C 103.1 £ ;rtttrc::ti,r For a siacil core or meant space trust .nary <br /> so?.;arnas:nN-General i7 a ;paned,indicate if there is tics is lttnra <br /> SC011.0.m . €ted litc project. <br /> YES C103.1 Construction For an alteration project,indicate if there is new lighting A-3 <br /> documents-General no lighting scope included in the project. <br /> LIGHTING CONTROLS <br /> YES C405.2 Lighting controls, -For all lighting fixtures,indicate lighting sensors <br /> general control method on plans for spaces and <br /> lighting zone(s)served,or exception taken <br /> C405.2, I.:endun€re level Indicate on plane all fixtures provided with <br /> Option 2 lighting o€trok I,I _:C`in lieu of C2405,2 lighting controls; <br /> (LLLC) provide-description of control capabilities and <br /> performance;:parn eters <br /> (3405,2.5, Ineltt.ine in dwelling Indicate method of,automatic control al.all <br /> heat 3 units pth miter . installed it.r.inaiaes in dwelling units in <br /> C° 0' =.1.1 hotel and all other buildines other than multifamily(occupancy <br /> t o 5.2.3.I than multifamily) or light're ucti n crinth'ils) <br /> a C-t D5.2.5„ Lighting in sleepit:.c indicate method of automatic off control of <br /> Item 2 units all installed luminaires in sieepitp units <br /> (vacar€c1-or key-card enn moli:also refer to <br /> Receptacles <br /> YES C405.2.3 Manual controls Indicate on plans the method of manual <br /> C405.2.3.1 lighting control,location of manual control <br /> C405.2.5 device and the area or specific application it <br /> serves <br /> YES C405.2.3.I Manual interior light Indicate on plans which method of manual A-3 <br /> C405.2.1.1 reduction controls 50%lighting load reduction is provided,or <br /> C405.2.4 indicate applicable exception <br /> YES C405.2.1 Method of automatic Indicate on plans the method of automatic A-3 <br /> C405.2.2.1 shut-off control shut-off control during unoccupied periods <br /> C405.2.1, (occupancy sensor,time switch or digital <br /> Exception 3 timer switch)for all lighting zones <br /> YES C405.2.I Occupant sensor Indicate on plans all luminaires that are a-3 <br /> controls controlled by occupant sensor controls; <br /> indicate controls are configured to turn <br /> luminaires 100%off when the space is <br /> unoccupied <br /> NA C405.2.I Occupant sensor Indicate if occupant sensor controls are <br /> C405.2.1.1 controls configured to be manual on or automatic on to <br /> not more than 50%power;indicate spaces <br /> eligible for exception that allows automatic on <br /> to 100%power <br /> Page 1/10".. <br />