Laserfiche WebLink
5FA Design Group, LLC <br /> EPROJECT NO. SHEET NO. <br /> STRUCTURAL I GEOTECHNICAI- I SPECIAL INSPECTIONS MFR22-156 <br /> PROJECT DATE <br /> Kobuke Residence Underpinning 8/19/2022 <br /> SUBJECT BY <br /> Safebase Crawlspace Stabilizer System MEK <br /> (E) FLOOR SHEATHING <br /> i <br /> (E) BOOR FRAMING TYP <br /> `---(E) FLOOR BEAM <br /> (4'/2"W MIN) <br /> TOP PLATE PER GENERAL. <br /> mu NOTES W/ (4) #9X3" <br /> ■ ■ WOOD SCREWS <br /> THREADED ROD PER <br /> GENERAL NOTES <br /> THREADED CAP PER <br /> GENERAL NOTES <br /> MAIN TUBE PER <br /> GENERAL NOTES <br /> LIGHTFOOT FOOTING PER <br /> GENERAL NOTES <br /> (E) INTERIOR GRADE ��� <br /> Note: Section above is a general representation of Stabilizer system, refer to plan for layout and project specific details. <br /> Safebase Crawlspace Stabilizer System= SB350 <br /> Pmax= 2.284 kips <br /> Maximum Tube Unbraced Length,dt= 3.000 ft <br /> Maximum Threaded Rod Unbraced Length, dtr= 3.000 in <br /> Eccentricity, emax= 1.000 in <br /> Moment= 2.284 in-kips <br /> Tube Properties <br /> Design Tube= 3.500 in <br /> Design Wall Thickness= 0.1196 in <br /> k= 1.00 <br /> r= 1.380 in <br /> A= 1.261 in2 <br /> c= 1.750 in <br /> S= 1.373 in3 <br /> I = 2.402 in4 <br /> E= 29000 ksi <br /> Fy= 50 ksi <br />