Laserfiche WebLink
MyBuildingPermit.com <br /> a service of eCityGov.net Construction Tip Sheet 05 <br /> Connections and Fasteners <br /> (All fasteners, nails, bolts, screws, and connectors must be corrosion resistant) <br /> Type of Connection: Notes: <br /> Manufactured Connectors Follow manufacturer's instructions <br /> Post to Footing Post base is required <br /> Post to Footing (High Winds) Consult with jurisdiction about additional uplift loads where wind <br /> exposure is greater than Risk Category B <br /> Post to Beam Connector is required <br /> Ledger to House Framing See information on Sheet 5 and Sheet 6 <br /> Joist to Beam or Girder (3) 8d —Toe nailed <br /> Blocking or Bridging to Joist (2) 10d — Toe nailed at each end <br /> Wooden Deck Boards (2) 8d threaded nails OR (2) No. 8 screws <br /> Composite Decking Follow manufacturer's instructions <br /> Post to Beam Connection with Knee Brace <br /> (Knee braces are required on posts greater than 4 feet in height.) <br /> Or 1/3 the height of the post. <br /> whichever is greater Beam splices must occur <br /> aver posts with 1-112"min.bearing <br /> Corrosion resistant, ' min. <br /> metal column cap. Girder beam <br /> Follow manufacturer's <br /> installation instructions, <br /> • <br /> s. <br /> I!F` <br /> 6 <br /> 4 ° 4 x 4 knee brace <br /> (1)3/8"diameter thru-bolt or 1r2 <br /> Alternate Knee Brace Detail. . lag screws with washers,top&bottom <br /> 2x4 knee brace face nailed ea.side of ` (typical) <br /> post and beam with 4-18d nails at each . Pressure treated <br /> face and connection ._ ` wood post <br /> January 14,2022 MyBuildingPermit.com I Basic Deck <br /> eCityGov.net <br /> 2005 C eCltyGavAlliance <br />